<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Copper - RLS Wacon analytics</title>
	<atom:link href="https://rls-wacon.de/en/product-category/water/manual-analysis/testsets-caldur-en/parameter-en/copper/feed/" rel="self" type="application/rss+xml" />
	<link>https://rls-wacon.de/product-category/wasser/manuelle-analytik/testsets-caldur/parameter/kupfer/</link>
	<description>Experts for water monitoring</description>
	<lastBuildDate>Thu, 12 Mar 2026 10:33:13 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://rls-wacon.de/wp-content/uploads/2024/04/cropped-Kreis_logo_gross-32x32.png</url>
	<title>Copper - RLS Wacon analytics</title>
	<link>https://rls-wacon.de/product-category/wasser/manuelle-analytik/testsets-caldur/parameter/kupfer/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Caldur® Copper &#8211; Photometric</title>
		<link>https://rls-wacon.de/en/produkt/caldur-copper-photometric/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Thu, 12 Mar 2026 10:33:13 +0000</pubDate>
				<guid isPermaLink="false">https://rls-wacon.de/produkt/caldur-copper-photometric/</guid>

					<description><![CDATA[<p>CALDUR® Copper Test Set &#8211; Photometric What is copper measured for? Copper (Cu) is an essential trace element, but can be harmful to health in high concentrations. The limit value for drinking water is 2 mg/l (Drinking Water Ordinance). Copper mainly enters drinking water through copper pipes, especially in soft, acidic water with a low [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/caldur-copper-photometric/">Caldur® Copper &#8211; Photometric</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>CALDUR® Copper Test Set &#8211; Photometric</h2>
<h3>What is copper measured for?</h3>
<p>Copper (Cu) is an essential trace element, but can be harmful to health in high concentrations. <strong>The limit value for drinking water is 2 mg/l</strong> (Drinking Water Ordinance). Copper mainly enters drinking water through copper pipes, especially in soft, acidic water with a low pH value.  </p>
<p>The photometric determination offers higher precision than the colorimetric method and is ideal for laboratory applications and professional water analysis.</p>
<h3>How does the test set work?</h3>
<p>The CALDUR® Copper Test Set &#8211; Photometric works according to the cuprizone method. The reagents are specially adapted to the WINLAB Data Line photometer. After adding the reagents and a reaction time of 5 minutes, the measured value is precisely determined photometrically.  </p>
<h3>Advantages of the CALDUR® test set</h3>
<ul class="feature-list">
<li>Measuring range 0.05 &#8211; 2 mg/l Cu
<p style="text-indent: 30px; font-style: italic;">Covers the entire relevant area</p>
</li>
<li>100 provisions per set
<p style="text-indent: 30px; font-style: italic;">Economical for regular checks</p>
</li>
<li>High precision due to photometric evaluation
<p style="text-indent: 30px; font-style: italic;">Objective, reproducible measurement results</p>
</li>
<li>Adapted to WINLAB Data Line photometer
<p style="text-indent: 30px; font-style: italic;">Optimum compatibility with CALDUR® system solutions</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/caldur-copper-photometric/">Caldur® Copper &#8211; Photometric</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Caldur® Copper &#8211; Colorimetric</title>
		<link>https://rls-wacon.de/en/produkt/caldur-copper-colorimetric/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Thu, 12 Mar 2026 10:32:49 +0000</pubDate>
				<guid isPermaLink="false">https://rls-wacon.de/produkt/caldur-copper-colorimetric/</guid>

					<description><![CDATA[<p>CALDUR® Copper Test Set &#8211; Colorimetric What is copper measured for? Copper (Cu) is an essential trace element, but can be harmful to health in high concentrations. The limit value for drinking water is 2 mg/l (Drinking Water Ordinance). Copper mainly enters drinking water through copper pipes, especially in soft, acidic water with a low [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/caldur-copper-colorimetric/">Caldur® Copper &#8211; Colorimetric</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>CALDUR® Copper Test Set &#8211; Colorimetric</h2>
<h3>What is copper measured for?</h3>
<p>Copper (Cu) is an essential trace element, but can be harmful to health in high concentrations. <strong>The limit value for drinking water is 2 mg/l</strong> (Drinking Water Ordinance). Copper mainly enters drinking water through copper pipes, especially in soft, acidic water with a low pH value.  </p>
<p>Elevated copper concentrations can lead to a greenish discoloration of the water, cause a metallic taste and trigger gastrointestinal complaints in sensitive people. In aquariums, even small amounts of copper are toxic to fish and invertebrates. </p>
<p>Regular monitoring of the copper content is therefore particularly important for new copper installations, in aquariums, swimming pools and in industrial water treatment.</p>
<h3>How does the test set work?</h3>
<p>The CALDUR® Copper Test Set &#8211; Colorimetric works according to the cuprizone method. Cuprizone forms a blue to violet color complex with copper(II) ions, the intensity of which is proportional to the copper concentration. </p>
<p>After the addition of two reagents and a reaction time of 5 minutes, the measured value is determined by direct color comparison with a 6-stage color chart.</p>
<h3>Advantages of the CALDUR® test set</h3>
<ul class="feature-list">
<li>Measuring range 0.05 &#8211; 2 mg/l Cu
<p style="text-indent: 30px; font-style: italic;">Covers the entire relevant range up to the drinking water limit value</p>
</li>
<li>100 provisions per set
<p style="text-indent: 30px; font-style: italic;">Economical for regular checks</p>
</li>
<li>Simple color comparison
<p style="text-indent: 30px; font-style: italic;">Fast on-site determination without measuring devices</p>
</li>
<li>Cuprizone method
<p style="text-indent: 30px; font-style: italic;">Proven, reliable detection method</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/caldur-copper-colorimetric/">Caldur® Copper &#8211; Colorimetric</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
