<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Sulphate - RLS Wacon analytics</title>
	<atom:link href="https://rls-wacon.de/en/product-category/water/manual-analysis/testsets-caldur-en/parameter-en/sulphate/feed/" rel="self" type="application/rss+xml" />
	<link>https://rls-wacon.de/product-category/wasser/manuelle-analytik/testsets-caldur/parameter/sulfat/</link>
	<description>Experts for water monitoring</description>
	<lastBuildDate>Thu, 12 Mar 2026 10:36:11 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://rls-wacon.de/wp-content/uploads/2024/04/cropped-Kreis_logo_gross-32x32.png</url>
	<title>Sulphate - RLS Wacon analytics</title>
	<link>https://rls-wacon.de/product-category/wasser/manuelle-analytik/testsets-caldur/parameter/sulfat/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Caldur® Sulfate 20 mg &#8211; Titrimetric</title>
		<link>https://rls-wacon.de/en/produkt/caldur-sulfate-20-mg-titrimetric/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Thu, 12 Mar 2026 10:36:11 +0000</pubDate>
				<guid isPermaLink="false">https://rls-wacon.de/produkt/caldur-sulfate-20-mg-titrimetric/</guid>

					<description><![CDATA[<p>CALDUR® Sulfate 20 mg test set &#8211; Titrimetric What is sulfate measured for? Sulphate (SO₄²-) is a naturally occurring anion in many bodies of water and mainly comes from the weathering of sulphate-containing minerals such as gypsum (CaSO₄) and anhydrite. In industrial processes, sulphate also enters the water through wastewater, cooling towers and chemical production [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/caldur-sulfate-20-mg-titrimetric/">Caldur® Sulfate 20 mg &#8211; Titrimetric</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>CALDUR® Sulfate 20 mg test set &#8211; Titrimetric</h2>
<h3>What is sulfate measured for?</h3>
<p>Sulphate (SO₄²-) is a naturally occurring anion in many bodies of water and mainly comes from the weathering of sulphate-containing minerals such as gypsum (CaSO₄) and anhydrite. In industrial processes, sulphate also enters the water through wastewater, cooling towers and chemical production processes. </p>
<p><strong>The limit value for sulphate in drinking water is 250 mg/l</strong> (Drinking Water Ordinance). Elevated sulphate concentrations can have a deleterious effect and impair the taste of the water. Sulphate monitoring is particularly important in industry, as high concentrations can lead to corrosion of concrete structures and pipelines.  </p>
<p>This test kit with a resolution of 20 mg/l SO₄²- per drop is optimized for higher concentrations and enables rapid determination in samples with elevated sulfate content.</p>
<h3>How does the test set work?</h3>
<p>The CALDUR® Sulfate 20 mg test kit works according to the principle of precipitation titration. A reagent is first added to the water sample. The titration solution is then added drop by drop until a color change indicates the end point.  </p>
<p><strong>Measuring principle:</strong> Barium ions from the titration solution react with sulphate ions and form poorly soluble barium sulphate. The end point is indicated by a Reagent. Each drop corresponds to 20 mg/l SO₄²-.  </p>
<p><strong>Calculation:</strong> Number of drops × 20 = sulphate concentration in mg/l.</p>
<h3>Advantages of the CALDUR® test set</h3>
<ul class="feature-list">
<li>Quick analysis in just 2 minutes
<p style="text-indent: 30px; font-style: italic;">Efficient on-site determination without laboratory equipment</p>
</li>
<li>Measured value 20 mg/l SO₄²- per drop
<p style="text-indent: 30px; font-style: italic;">Larger measuring range for higher concentrations</p>
</li>
<li>30 provisions per set
<p style="text-indent: 30px; font-style: italic;">Economical for regular monitoring</p>
</li>
<li>Proven precipitation titration
<p style="text-indent: 30px; font-style: italic;">Reliable and reproducible results</p>
</li>
<li>Faster titration at high concentrations
<p style="text-indent: 30px; font-style: italic;">Fewer drops required than with the 10 mg test set</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/caldur-sulfate-20-mg-titrimetric/">Caldur® Sulfate 20 mg &#8211; Titrimetric</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Caldur® Sulfate 10 mg &#8211; Titrimetric</title>
		<link>https://rls-wacon.de/en/produkt/caldur-sulfate-10-mg-titrimetric/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Thu, 12 Mar 2026 10:36:09 +0000</pubDate>
				<guid isPermaLink="false">https://rls-wacon.de/produkt/caldur-sulfate-10-mg-titrimetric/</guid>

					<description><![CDATA[<p>CALDUR® Sulfate 10 mg test set &#8211; Titrimetric What is sulfate measured for? Sulphate (SO₄²-) is a naturally occurring anion in many bodies of water and mainly comes from the weathering of sulphate-containing minerals such as gypsum (CaSO₄) and anhydrite. In industrial processes, sulphate also enters the water through wastewater, cooling towers and chemical production [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/caldur-sulfate-10-mg-titrimetric/">Caldur® Sulfate 10 mg &#8211; Titrimetric</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>CALDUR® Sulfate 10 mg test set &#8211; Titrimetric</h2>
<h3>What is sulfate measured for?</h3>
<p>Sulphate (SO₄²-) is a naturally occurring anion in many bodies of water and mainly comes from the weathering of sulphate-containing minerals such as gypsum (CaSO₄) and anhydrite. In industrial processes, sulphate also enters the water through wastewater, cooling towers and chemical production processes. </p>
<p><strong>The limit value for sulphate in drinking water is 250 mg/l</strong> (Drinking Water Ordinance). Elevated sulphate concentrations can have a deleterious effect and impair the taste of the water. Sulphate monitoring is particularly important in industry, as high concentrations can lead to corrosion of concrete structures and pipelines.  </p>
<p>This test set with a resolution of 10 mg/l SO₄²- per drop is ideal for monitoring drinking water, process water and industrial applications in the medium concentration range.</p>
<h3>How does the test set work?</h3>
<p>The CALDUR® Sulfate 10 mg test kit works according to the principle of precipitation titration. The water sample is first passed through an ion exchanger to remove interfering ions. A reagent is then added and titrated drop by drop until a color change indicates the end point.  </p>
<p><strong>Measuring principle:</strong> Barium ions from the titration solution react with sulphate ions and form poorly soluble barium sulphate. The end point is indicated by a Reagent. Each drop corresponds to 10 mg/l SO₄²-.  </p>
<p><strong>Calculation:</strong> Number of drops × 10 = sulphate concentration in mg/l.</p>
<h3>Advantages of the CALDUR® test set</h3>
<ul class="feature-list">
<li>Quick analysis in just 2 minutes
<p style="text-indent: 30px; font-style: italic;">Efficient on-site determination without laboratory equipment</p>
</li>
<li>Measured value 10 mg/l SO₄²- per drop
<p style="text-indent: 30px; font-style: italic;">Precise measurement in the medium concentration range</p>
</li>
<li>30 provisions per set
<p style="text-indent: 30px; font-style: italic;">Economical for regular monitoring</p>
</li>
<li>Proven precipitation titration
<p style="text-indent: 30px; font-style: italic;">Reliable and reproducible results</p>
</li>
<li>Ion exchanger for the elimination of impurities
<p style="text-indent: 30px; font-style: italic;">Precise results even with complex water matrices</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/caldur-sulfate-10-mg-titrimetric/">Caldur® Sulfate 10 mg &#8211; Titrimetric</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
