<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Accessories Archive - RLS Wacon analytics</title>
	<atom:link href="https://rls-wacon.de/en/product-category/water/online-analytics/accessories/feed/" rel="self" type="application/rss+xml" />
	<link>https://rls-wacon.de/product-category/wasser/online-analytik/zubehoer/</link>
	<description>Experts for water monitoring</description>
	<lastBuildDate>Tue, 31 Mar 2026 13:47:42 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://rls-wacon.de/wp-content/uploads/2024/04/cropped-Kreis_logo_gross-32x32.png</url>
	<title>Accessories Archive - RLS Wacon analytics</title>
	<link>https://rls-wacon.de/product-category/wasser/online-analytik/zubehoer/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SYCON maintenance set</title>
		<link>https://rls-wacon.de/en/produkt/sycon-maintenance-set/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Tue, 31 Mar 2026 13:47:42 +0000</pubDate>
				<guid isPermaLink="false">https://rls-wacon.de/produkt/sycon-maintenance-set/</guid>

					<description><![CDATA[<p>Maintenance set for SYCON analyzers &#8211; Reliable operation through regular maintenance Why is regular maintenance important? The SYCON analyzers from RLS Wacon work fully automatically and reliably &#8211; provided that the wearing parts are replaced at regular intervals. The peristaltic pump cassette is the central dosing element: it delivers the Reagent precisely into the measuring [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sycon-maintenance-set/">SYCON maintenance set</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 style="color: #0069b3;">Maintenance set for SYCON analyzers &#8211; Reliable operation through regular maintenance</h2>
<h3 style="color: #0069b3;">Why is regular maintenance important?</h3>
<p>The SYCON analyzers from RLS Wacon work fully automatically and reliably &#8211; provided that the wearing parts are replaced at regular intervals. The peristaltic pump cassette is the central dosing element: it delivers the Reagent precisely into the measuring cell and thus significantly determines the measuring accuracy.   <strong>Worn pump hoses lead to inaccurate dosing quantities and therefore to falsified measurement results.</strong></p>
<p>Seals (O-rings), suction lance and agitator blades are also subject to natural wear due to constant contact with water and indicator solution. Replacing these components in good time prevents leaks, dosing errors and unplanned device failures. </p>
<h3 style="color: #0069b3;">When should you wait?</h3>
<p>The maintenance intervals vary depending on the appliance type:</p>
<table class="h3-table">
<thead>
<tr>
<th style="background-color: #0069b3; color: #ffffff;">Device type</th>
<th style="background-color: #0069b3; color: #ffffff;">Cleaning the measuring chamber</th>
<th style="background-color: #0069b3; color: #ffffff;">Installation of the maintenance set</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>SYCON 2502/2602</strong></td>
<td>Every 6 months</td>
<td>Every 30,000 analyses or 24 months</td>
</tr>
<tr>
<td><strong>SYCON 2702/2802/P</strong></td>
<td>Every 6 months</td>
<td>Every 30,000 analyses or 24 months</td>
</tr>
<tr>
<td><strong>SYCON Fe</strong></td>
<td>Every 3 months</td>
<td>Every 15,000 analyses or 24 months</td>
</tr>
<tr>
<td><strong>SYCON SiO2</strong></td>
<td>Every 4 weeks</td>
<td>Every 10,000 analyses or 6 months</td>
</tr>
<tr>
<td><strong>SYCON BoB</strong></td>
<td>Every 6 months</td>
<td>Every 15,000 analyses or 12 months</td>
</tr>
</tbody>
</table>
<p>If the water or ambient temperature is high or the water is organically contaminated, the cleaning intervals should be shortened if necessary. Cleaning the measuring chamber takes approx. 20 minutes. </p>
<h3 style="color: #0069b3;">What is included in the maintenance kit?</h3>
<p>Each maintenance set contains all the wear parts required for complete maintenance: Hose pump cassette, bottle connector, suction lance, O-rings, dosing O-ring and agitator blade. The exact scope is tailored to the respective appliance type. </p>
<h3 style="color: #0069b3;">Advantages of the original maintenance set</h3>
<ul class="feature-list">
<li>All wear parts in one set
<p style="text-indent: 30px; font-style: italic;">No tedious searching for individual spare parts &#8211; everything is coordinated</p>
</li>
<li>Original RLS Wacon quality
<p style="text-indent: 30px; font-style: italic;">Precisely manufactured components for maximum measuring accuracy and service life</p>
</li>
<li>Perfect fit for your device type
<p style="text-indent: 30px; font-style: italic;">Select the set for your specific SYCON model &#8211; with the right pump cassettes and seals</p>
</li>
<li>Easy replacement without special tools
<p style="text-indent: 30px; font-style: italic;">All components can be replaced in a few simple steps &#8211; detailed instructions in the device manual</p>
</li>
<li>Plannable maintenance costs
<p style="text-indent: 30px; font-style: italic;">One set covers complete maintenance &#8211; no hidden costs for missing parts</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sycon-maintenance-set/">SYCON maintenance set</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Sample cooler AC 100 without valves</title>
		<link>https://rls-wacon.de/en/produkt/sample-cooler-ac-100-without-valves/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Thu, 14 Sep 2023 13:54:47 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/sample-cooler-ac-100-without-valves/</guid>

					<description><![CDATA[<p>Our AC series sample coolers are ideal for manually taking water samples that need to be cooled down to normal ambient temperature for analytical purposes. The sample coolers from RLS Wacon are used in boiler house operation in particular.</p>
<p>The special features of the AC series sample coolers include</p>
<ul>
<li>Sample cooler optionally with or without valve</li>
<li>Compact design</li>
<li>Use of high-quality stainless steel</li>
</ul>
<p>&#160;</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sample-cooler-ac-100-without-valves/">Sample cooler AC 100 without valves</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The AC 100 sample cooler is used to take a water sample for manual analysis from a hot water pipe. By installing it in the sampling line and connecting a cold water line, samples such as boiler water, boiler feed water and condensate can be qualitatively monitored. The samples are then analyzed using our CALDUR test kits, for example.</p>
<p>The special features of the PC series sample coolers include</p>
<ul>
<li>Compact design</li>
<li>Use of high-quality stainless steel</li>
<li>Inlet pressure cooling water up to 8 bar</li>
</ul>
<hr class="system-pagebreak" title="General specifications" />
<table class="wacon-table">
<tbody>
<tr>
<td>Parameters</td>
<td>Value / Range</td>
</tr>
<tr>
<td>Weight</td>
<td>2.4 kg</td>
</tr>
<tr>
<td>Dimensions</td>
<td>Body 100 x 225 mm / cooling coil 2.6 m x 8 mm</td>
</tr>
<tr>
<td>Material</td>
<td>Stainless steel 1.4571, electropolished</td>
</tr>
</tbody>
</table>
<hr class="system-pagebreak" title="Technical data" />
<table class="wacon-table">
<tbody>
<tr>
<td>Parameters</td>
<td>Value / Range</td>
</tr>
<tr>
<td>Installation</td>
<td>Wall mounting in closed rooms</td>
</tr>
<tr>
<td>Cooling water inlet</td>
<td>8 mm</td>
</tr>
<tr>
<td>Cooling water outlet</td>
<td>1/2&#8243; external thread</td>
</tr>
<tr>
<td>Sample water input</td>
<td>8 mm</td>
</tr>
<tr>
<td>Sample water output</td>
<td>8 mm</td>
</tr>
<tr>
<td>Nominal pressure</td>
<td>8 bar (open outlets)</td>
</tr>
<tr>
<td>Cooling coil</td>
<td>16 bar</td>
</tr>
<tr>
<td>Fastening</td>
<td>2-fold, spacing 54 mm, screw diameter 4 mm</td>
</tr>
</tbody>
</table>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sample-cooler-ac-100-without-valves/">Sample cooler AC 100 without valves</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Sample cooler AC 400 without valves</title>
		<link>https://rls-wacon.de/en/produkt/sample-cooler-ac-400-without-valves/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Thu, 14 Sep 2023 13:54:47 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/sample-cooler-ac-400-without-valves/</guid>

					<description><![CDATA[<p>Our AC series sample coolers are ideal for manually taking water samples that need to be cooled down to normal ambient temperature for analytical purposes. The sample coolers from RLS Wacon are used in boiler house operation in particular.</p>
<p>The special features of the AC series sample coolers include</p>
<ul>
<li>Sample cooler optionally with or without valve</li>
<li>Compact design</li>
<li>Use of high-quality stainless steel</li>
</ul>
<p>&#160;</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sample-cooler-ac-400-without-valves/">Sample cooler AC 400 without valves</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Our AC series sample coolers are ideal for manually taking water samples that need to be cooled down to normal ambient temperature for analytical purposes. The sample coolers from RLS Wacon are used in boiler house operation in particular.</p>
<p>The special features of the AC series sample coolers include</p>
<ul>
<li>Sample cooler optionally with or without valve</li>
<li>Compact design</li>
<li>Use of high-quality stainless steel</li>
</ul>
<p>&nbsp;</p>
<hr class="system-pagebreak" title="General specifications" />
<table class="wacon-table">
<tbody>
<tr>
<td>Parameters</td>
<td>Value / Range</td>
</tr>
<tr>
<td>Weight</td>
<td>3.7 kg</td>
</tr>
<tr>
<td>Dimensions</td>
<td>Body 100 x 448 mm / cooling coil 5 m x 8 mm</td>
</tr>
<tr>
<td>Material</td>
<td>Stainless steel 1.4571, electropolished</td>
</tr>
</tbody>
</table>
<hr class="system-pagebreak" title="Technical data" />
<table class="wacon-table">
<tbody>
<tr>
<td>Parameters</td>
<td>Value / Range</td>
</tr>
<tr>
<td>Installation</td>
<td>Wall mounting in closed rooms</td>
</tr>
<tr>
<td>Cooling water inlet</td>
<td>8 mm</td>
</tr>
<tr>
<td>Cooling water outlet</td>
<td>1/2&#8243; external thread</td>
</tr>
<tr>
<td>Sample water input</td>
<td>8 mm</td>
</tr>
<tr>
<td>Sample water output</td>
<td>8 mm</td>
</tr>
<tr>
<td>Nominal pressure</td>
<td>16 bar (open outlets)</td>
</tr>
<tr>
<td>Cooling coil</td>
<td>16 bar</td>
</tr>
<tr>
<td>Fastening</td>
<td>2-fold, spacing 54 mm, screw diameter 4 mm</td>
</tr>
</tbody>
</table>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sample-cooler-ac-400-without-valves/">Sample cooler AC 400 without valves</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Sample cooler AC 100 with valves</title>
		<link>https://rls-wacon.de/en/produkt/sample-cooler-ac-100-with-valves/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Thu, 14 Sep 2023 13:54:47 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/sample-cooler-ac-100-with-valves/</guid>

					<description><![CDATA[<p>The PC 200 pre-cooler is used to take a water sample from a hot water pipe. By installing it in the sampling line and connecting a cold water line, samples such as boiler water, boiler feed water and condensate can be automatically monitored for quality. Our SYCON BOB online analyzer is used downstream of the sample cooler to determine the water hardness.</p>
<p>The special features of the PC series sample coolers include</p>
<ul>
<li>Compact design</li>
<li>Optimally matched to the analyzers of the Sycon series</li>
<li>Use of high-quality stainless steel</li>
<li>Sample water inlet pressure up to 16 bar</li>
<li>Inlet pressure cooling water up to 8 bar</li>
</ul>
<p>&#160;</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sample-cooler-ac-100-with-valves/">Sample cooler AC 100 with valves</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The AC 100 sample cooler is used to take a water sample for manual analysis from a hot water pipe. By installing it in the sampling line and connecting a cold water line, samples such as boiler water, boiler feed water and condensate can be qualitatively monitored. The samples are then analyzed using our CALDUR test kits, for example.</p>
<p>The special features of the PC series sample coolers include</p>
<ul>
<li>Compact design</li>
<li>Use of high-quality stainless steel</li>
<li>Inlet pressure cooling water up to 8 bar</li>
</ul>
<hr class="system-pagebreak" title="General specifications" />
<table class="wacon-table">
<tbody>
<tr>
<td>Parameters</td>
<td>Value / Range</td>
</tr>
<tr>
<td>Weight</td>
<td>2.4 kg without valves / 2.72 kg with valves</td>
</tr>
<tr>
<td>Dimensions</td>
<td>Body 100 x 225 mm / cooling coil 2.6 m x 8 mm</td>
</tr>
<tr>
<td>Material</td>
<td>Stainless steel 1.4571, electropolished</td>
</tr>
</tbody>
</table>
<hr class="system-pagebreak" title="Technical data" />
<table class="wacon-table">
<tbody>
<tr>
<td>Parameters</td>
<td>Value / Range</td>
</tr>
<tr>
<td>Installation</td>
<td>Wall mounting in closed rooms</td>
</tr>
<tr>
<td>Cooling water inlet</td>
<td>8 mm</td>
</tr>
<tr>
<td>Cooling water outlet</td>
<td>1/2&#8243; external thread</td>
</tr>
<tr>
<td>Sample water input</td>
<td>8 mm</td>
</tr>
<tr>
<td>Sample water output</td>
<td>8 mm</td>
</tr>
<tr>
<td>Nominal pressure</td>
<td>8 bar (open outlets)</td>
</tr>
<tr>
<td>Cooling coil</td>
<td>16 bar</td>
</tr>
<tr>
<td>Fastening</td>
<td>2-fold, spacing 54 mm, screw diameter 4 mm</td>
</tr>
</tbody>
</table>
<hr class="system-pagebreak" title="Accessories" />
<table class="wacon-table">
<tbody>
<tr>
<td>Item number</td>
<td>Article description</td>
</tr>
<tr>
<td>30-012110</td>
<td>Hot water valve type HWV 100, fine control valve made of brass, PN 50 bar, 100°C</td>
</tr>
<tr>
<td>30-012121</td>
<td>Cold water valve type KWV 150, 1/4<sup>&#8221; </sup>ball valve nickel-plated brass with screw connections for 8 mm pipe</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sample-cooler-ac-100-with-valves/">Sample cooler AC 100 with valves</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>System separator</title>
		<link>https://rls-wacon.de/en/produkt/system-separator/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Thu, 14 Sep 2023 13:54:46 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/system-separator/</guid>

					<description><![CDATA[<p>System separator for preventing backflow when measuring on a drinking water pipe in accordance with EN1717:2001 hazard class 3.</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/system-separator/">System separator</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/system-separator/">System separator</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Cam load switch</title>
		<link>https://rls-wacon.de/en/produkt/cam-load-switch/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Thu, 14 Sep 2023 13:54:46 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/cam-load-switch/</guid>

					<description><![CDATA[<p>Wall-mountable load switch for disconnecting the analyzer and connected accessories during installation and maintenance.</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/cam-load-switch/">Cam load switch</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/cam-load-switch/">Cam load switch</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Sampling valve</title>
		<link>https://rls-wacon.de/en/produkt/sampling-valve/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Thu, 14 Sep 2023 13:54:46 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/sampling-valve/</guid>

					<description><![CDATA[<p>Sampling valve for taking water samples from tanks and pipes.</p>
<p>Connection 3/8" AG alternatively when using the supplied adapter 1/2" AG connection</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sampling-valve/">Sampling valve</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sampling-valve/">Sampling valve</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Connection set</title>
		<link>https://rls-wacon.de/en/produkt/connection-set/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Thu, 14 Sep 2023 13:54:41 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/connection-set/</guid>

					<description><![CDATA[<p>The connection set for Sycon analyzers enables the device to be easily connected to standard pipe connections with a 1/4 inch tapered external thread or 1/2 inch tapered internal thread.</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/connection-set/">Connection set</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<hr class="system-pagebreak" title="Suitable devices" />
<ul>
<li>all analyzers of the Sycon series</li>
</ul>
<hr class="system-pagebreak" title="Components" />
<p>The connection set includes the following items:</p>
<ul>
<li>1x reducing nipple stainless steel 1.4408 V4A 1/2&#8243; to 1/4&#8243; (conical external thread)</li>
<li>1x socket ball valve stainless steel 1.4408 V4A with 1/4&#8243; (cylindrical internal thread)</li>
<li>1x straight screw-in fitting, nickel-plated brass, 1/4&#8243; (cylindrical external thread with sealing ring), hose connection external diameter 6 mm</li>
<li>5 m plastic hose, outer diameter 6 mm</li>
</ul>
<hr class="system-pagebreak" title="Application notes" />
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/connection-set/">Connection set</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Spirax Sarco SCS 20 pre-cooler</title>
		<link>https://rls-wacon.de/en/produkt/spirax-sarco-scs-20-pre-cooler/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Thu, 14 Sep 2023 13:54:41 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/spirax-sarco-scs-20-pre-cooler/</guid>

					<description><![CDATA[<p>The SCS 20 upstream cooler is used to take a water sample from a hot water pipe up to 100 °C. By installing it in the sampling line and connecting a cold water line, samples such as boiler water, boiler feed water and condensate can be automatically monitored for quality. Our SYCON BOB online analyzer is used downstream of the sample cooler to determine the water hardness.</p>
<p>The special features of the sample coolers include</p>
<ul>
<li>Compact design</li>
<li>Optimally matched to the analyzers of the Sycon series</li>
<li>Use of high-quality stainless steel</li>
<li>Sample water inlet pressure up to 20 bar</li>
<li>Inlet pressure cooling water up to 10 bar</li>
</ul>
<p>&#160;</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/spirax-sarco-scs-20-pre-cooler/">Spirax Sarco SCS 20 pre-cooler</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<hr class="system-pagebreak" title="General specifications" />
<table class="wacon-table">
<tbody>
<tr>
<td>Parameters</td>
<td>Value / Range</td>
</tr>
<tr>
<td>Dimensions</td>
<td>Body 410 mm x 90 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>4.2 kg</td>
</tr>
<tr>
<td>Material</td>
<td>Stainless steel 1.4404</td>
</tr>
</tbody>
</table>
<hr class="system-pagebreak" title="Technical data" />
<table class="wacon-table">
<tbody>
<tr>
<td>Parameters</td>
<td>Value / Range</td>
</tr>
<tr>
<td>Installation</td>
<td>Wall mounting in closed rooms</td>
</tr>
<tr>
<td>Tubes</td>
<td>6 mm outer diameter</td>
</tr>
<tr>
<td>Cooling coil</td>
<td>20 bar</td>
</tr>
<tr>
<td>Housing</td>
<td>10 bar</td>
</tr>
</tbody>
</table>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/spirax-sarco-scs-20-pre-cooler/">Spirax Sarco SCS 20 pre-cooler</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Sample cooler AC 400 with valves</title>
		<link>https://rls-wacon.de/en/produkt/sample-cooler-ac-400-with-valves/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Thu, 14 Sep 2023 13:54:41 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/sample-cooler-ac-400-with-valves/</guid>

					<description><![CDATA[<p>Our AC series sample coolers are ideal for manually taking water samples that need to be cooled down to normal ambient temperature for analytical purposes. The sample coolers from RLS Wacon are used in boiler house operation in particular.</p>
<p>The special features of the AC series sample coolers include</p>
<ul>
<li>Sample cooler optionally with or without valve</li>
<li>Compact design</li>
<li>Use of high-quality stainless steel</li>
</ul>
<p>&#160;</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sample-cooler-ac-400-with-valves/">Sample cooler AC 400 with valves</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Our AC series sample coolers are ideal for manually taking water samples that need to be cooled down to normal ambient temperature for analytical purposes. The sample coolers from RLS Wacon are used in boiler house operation in particular.</p>
<p>The special features of the AC series sample coolers include</p>
<ul>
<li>Sample cooler optionally with or without valve</li>
<li>Compact design</li>
<li>Use of high-quality stainless steel</li>
</ul>
<p>&nbsp;</p>
<hr class="system-pagebreak" title="General specifications" />
<table class="wacon-table">
<tbody>
<tr>
<td>Parameters</td>
<td>Value / Range</td>
</tr>
<tr>
<td>Weight</td>
<td>3.7 kg without valves / 4.18 kg with valves</td>
</tr>
<tr>
<td>Dimensions</td>
<td>Body 100 x 448 mm / cooling coil 5 m x 8 mm</td>
</tr>
<tr>
<td>Material</td>
<td>Stainless steel 1.4571, electropolished</td>
</tr>
</tbody>
</table>
<hr class="system-pagebreak" title="Technical data" />
<table class="wacon-table">
<tbody>
<tr>
<td>Parameters</td>
<td>Value / Range</td>
</tr>
<tr>
<td>Installation</td>
<td>Wall mounting in closed rooms</td>
</tr>
<tr>
<td>Cooling water inlet</td>
<td>8 mm</td>
</tr>
<tr>
<td>Cooling water outlet</td>
<td>1/2&#8243; external thread</td>
</tr>
<tr>
<td>Sample water input</td>
<td>8 mm</td>
</tr>
<tr>
<td>Sample water output</td>
<td>8 mm</td>
</tr>
<tr>
<td>Nominal pressure</td>
<td>16 bar (open outlets)</td>
</tr>
<tr>
<td>Cooling coil</td>
<td>16 bar</td>
</tr>
<tr>
<td>Fastening</td>
<td>2-fold, spacing 54 mm, screw diameter 4 mm</td>
</tr>
</tbody>
</table>
<hr class="system-pagebreak" title="Accessories" />
<table class="wacon-table">
<tbody>
<tr>
<td>Item number</td>
<td>Article description</td>
</tr>
<tr>
<td>30-012115</td>
<td>Hot water valve type HWV 400, VA, max. Inlet pressure 200 bar, 250°C</td>
</tr>
<tr>
<td>30-012125</td>
<td>Cold water valve type KWV 400, 1/2<sup>&#8221; </sup>nickel-plated brass ball valve with screw connections, max. Inlet pressure 10 bar</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sample-cooler-ac-400-with-valves/">Sample cooler AC 400 with valves</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>