<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>p-value Archive - RLS Wacon analytics</title>
	<atom:link href="https://rls-wacon.de/en/product-category/water/online-analytics/parameter-en-2/p-value/feed/" rel="self" type="application/rss+xml" />
	<link>https://rls-wacon.de/product-category/wasser/online-analytik/on-parameter/p-wert-online/</link>
	<description>Experts for water monitoring</description>
	<lastBuildDate>Thu, 16 Apr 2026 13:32:48 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://rls-wacon.de/wp-content/uploads/2024/04/cropped-Kreis_logo_gross-32x32.png</url>
	<title>p-value Archive - RLS Wacon analytics</title>
	<link>https://rls-wacon.de/product-category/wasser/online-analytik/on-parameter/p-wert-online/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>p-value P25 series</title>
		<link>https://rls-wacon.de/en/produkt/p-value-p25-series/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Tue, 17 Mar 2026 13:31:56 +0000</pubDate>
				<guid isPermaLink="false">https://rls-wacon.de/produkt/p-value-p25-series/</guid>

					<description><![CDATA[<p>Reagent p-value P25 series What is the p-value measured for? The p-value (also acid capacity up to pH 8.2 or m-value/alkalinity) describes the concentration of hydroxide and carbonate ions in the water. It is a decisive parameter in boiler water and cooling water chemistry: Boiler water: The p-value is a key parameter for correct alkalization. [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/p-value-p25-series/">p-value P25 series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Reagent p-value P25 series</h2>
<h3>What is the p-value measured for?</h3>
<p>The p-value (also acid capacity up to pH 8.2 or m-value/alkalinity) describes the concentration of hydroxide and carbonate ions in the water. It is a decisive parameter in boiler water and cooling water chemistry: </p>
<ul class="feature-list">
<li><strong>Boiler water:</strong> The p-value is a key parameter for correct alkalization. Too low values lead to corrosion, too high values can cause foaming and overflow problems. </li>
<li><strong>Steam and condensate systems:</strong> Monitoring the p-value ensures that the alkalization remains in the optimum range.</li>
<li><strong>Cooling water systems:</strong> The p-value influences the corrosion and limescale separation behavior.</li>
<li><strong>Industrial process water:</strong> control of water chemistry in closed circuits.</li>
</ul>
<h3>How does the Reagent work?</h3>
<p>The P25 Reagents are liquid color reagents for fully automated p-value determination with the SYCON P analyzer. The device automatically takes a water sample, precisely doses the Reagent and measures the resulting coloration photometrically. </p>
<p>Two measuring ranges are available: P25-5 for the low range (0.2-5.0 mmol/l) and P25-20 for higher concentrations (0.8-20.0 mmol/l).</p>
<h3>Advantages of the P25 series</h3>
<ul class="feature-list">
<li>Two measuring ranges: P25-5 (0.2-5 mmol/l) and P25-20 (0.8-20 mmol/l)
<p style="text-indent: 30px; font-style: italic;">Precise measurement over a wide concentration range</p>
</li>
<li>Fully automatic measurement with the SYCON P
<p style="text-indent: 30px; font-style: italic;">Continuous 24/7 monitoring of boiler water chemistry</p>
</li>
<li>High-quality raw materials and our own recipe
<p style="text-indent: 30px; font-style: italic;">Manufactured by RLS Wacon &#8211; Made in Germany</p>
</li>
<li>Single batch calibration
<p style="text-indent: 30px; font-style: italic;">Consistently high precision with every delivery</p>
</li>
<li>Available as single bottle (500 ml) and value pack (4 × 500 ml)
<p style="text-indent: 30px; font-style: italic;">Economical container sizes for every need</p>
</li>
<li>24 months shelf life
<p style="text-indent: 30px; font-style: italic;">Cost-efficient stockpiling</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/p-value-p25-series/">p-value P25 series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SYCON P</title>
		<link>https://rls-wacon.de/en/produkt/sycon-p/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Sat, 11 Mar 2023 21:13:14 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/sycon-p/</guid>

					<description><![CDATA[<p><a id="intro"></a>The SYCON P is a titration device for measuring the +p value. In addition to the usual relays and input contacts, the online analyzer has a 20 mA current and RS485 interface with Modbus RTU protocol.</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sycon-p/">SYCON P</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 style="color: #0069b3;">SYCON P &#8211; Online titration device for automatic measurement of the p-value</h2>
<h3 style="color: #0069b3;">What is the p-value and why is it measured?</h3>
<p>The p-value (phenolphthalein alkalinity) describes the buffering capacity of water against acid input. It measures the hydroxide ions (OH-) and carbonate ions (CO₃²-) dissolved in the water, which are converted into water (H₂O) and hydrogen carbonate (HCO₃-) during titration. The measurement result is given in mmol/l.  </p>
<p><strong>Without a sufficient p-value, water has hardly any buffering capacity &#8211; even small amounts of acid can shift the pH value into the acidic range.</strong>  In practice, the p-value is therefore a decisive parameter for corrosion protection: in steam boiler systems, cooling water circuits and industrial treatment plants, the alkalinity of the water must be continuously monitored in order to prevent corrosion on pipes, heat exchangers and boiler components.</p>
<h3 style="color: #0069b3;">What is the SYCON P?</h3>
<p>The SYCON P from RLS Wacon is a fully automatic online titration device for the quantitative determination of the p-value in process water. It is based on the proven SYCON platform and offers the full range of functions of the Premium series: two programmable limit values, four relay outputs, an RS485 interface with Modbus RTU and an analog output 0/4-20 mA. </p>
<p>With two Reagents (P25-5 and P25-20), the device covers a measuring range of 0.2 to 20 mmol/l and is therefore suitable both for the fine monitoring of low-alkaline water and for highly alkaline applications.</p>
<h3 style="color: #0069b3;">How does the SYCON P work?</h3>
<p>The SYCON P works according to the <strong>colorimetric titration method</strong>. The dye phenolphthalein contained in the Reagent is colorless below pH 8.2 and intensely pink to violet above this level. During the measurement, an alkaline water sample (pH &gt; 8.2) is automatically fed into the measuring chamber and titrated step by step with the Reagent. An optical sensor detects the color change at the pH 8.2 point and calculates the p-value.   </p>
<p>The analysis time is approx. 3 minutes. The indicator consumption is only 0.05 to 0.6 ml per analysis, depending on the measured p-value. </p>
<h3 style="color: #0069b3;">Advantages of the SYCON P</h3>
<ul class="feature-list">
<li>Exact determination of measured values by titration method
<p style="text-indent: 30px; font-style: italic;">Quantitative determination of the p-value with ± 5 % accuracy and ± 2.5 % repeatability</p>
</li>
<li>Continuous online monitoring of a critical corrosion parameter
<p style="text-indent: 30px; font-style: italic;">Protects boilers, pipes and heat exchangers from acid-induced corrosion</p>
</li>
<li>Two measuring ranges for different applications
<p style="text-indent: 30px; font-style: italic;">P25-5 (0.2-5 mmol/l or 0.01-0.5 ppm) for low alkaline water, P25-20 (0.8-20 mmol/l or 0.2-6.0 ppm) for highly alkaline applications</p>
</li>
<li>RS485 interface with Modbus RTU
<p style="text-indent: 30px; font-style: italic;">Direct query of measured values and device parameters by a PLC &#8211; seamless integration into the system automation</p>
</li>
<li>Two freely programmable limit values
<p style="text-indent: 30px; font-style: italic;">Pre-alarm and main alarm or monitoring of a bandwidth with lower and upper threshold value</p>
</li>
<li>4 potential-free relay outputs
<p style="text-indent: 30px; font-style: italic;">Limit value 1, limit value 2 / indicator level, device fault, analysis active / cooling water valve</p>
</li>
<li>Self-calibrating full color sensor
<p style="text-indent: 30px; font-style: italic;">No manual calibration &#8211; automatic compensation for ambient light, contamination and turbidity</p>
</li>
<li>Very low indicator consumption
<p style="text-indent: 30px; font-style: italic;">0.05-0.6 ml per analysis &#8211; one 500 ml bottle is sufficient for numerous analyses</p>
</li>
<li>9-language graphic display with SD card
<p style="text-indent: 30px; font-style: italic;">Complete logging, installation wizard, software updates via SD card</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sycon-p/">SYCON P</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>