<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Water hardness Archive - RLS Wacon analytics</title>
	<atom:link href="https://rls-wacon.de/en/product-category/water/online-analytics/parameter-en-2/water-hardness/feed/" rel="self" type="application/rss+xml" />
	<link>https://rls-wacon.de/product-category/wasser/online-analytik/on-parameter/gesamthaerte-online/</link>
	<description>Experts for water monitoring</description>
	<lastBuildDate>Thu, 16 Apr 2026 13:32:29 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://rls-wacon.de/wp-content/uploads/2024/04/cropped-Kreis_logo_gross-32x32.png</url>
	<title>Water hardness Archive - RLS Wacon analytics</title>
	<link>https://rls-wacon.de/product-category/wasser/online-analytik/on-parameter/gesamthaerte-online/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Total value LHV series</title>
		<link>https://rls-wacon.de/en/produkt/total-value-lhv-series/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Tue, 17 Mar 2026 14:56:49 +0000</pubDate>
				<guid isPermaLink="false">https://rls-wacon.de/produkt/total-value-lhv-series/</guid>

					<description><![CDATA[<p>Reagent total hardness LHV series Why is the total hardness measured with LHV? The LHV series has been specially developed for total hardness measurement with analyzers from the LIMES series. The LIMES devices work purely as limit value monitors and continuously monitor whether a defined hardness limit value is exceeded or not reached. Typical areas [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/total-value-lhv-series/">Total value LHV series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Reagent total hardness LHV series</h2>
<h3>Why is the total hardness measured with LHV?</h3>
<p>The LHV series has been specially developed for total hardness measurement with analyzers from the LIMES series. The LIMES devices work purely as limit value monitors and continuously monitor whether a defined hardness limit value is exceeded or not reached. </p>
<p>Typical areas of application:</p>
<ul class="feature-list">
<li><strong>Softening systems:</strong> Monitoring of the drain water after ion exchangers &#8211; immediate detection of resin breakthroughs.</li>
<li><strong>Boiler feed water:</strong> Ensure that the required residual hardness is maintained in order to avoid limescale deposits.</li>
<li><strong>Reverse osmosis systems:</strong> Continuous control of the permeate quality.</li>
<li><strong>Drinking water treatment:</strong> Automated quality assurance of water hardness.</li>
</ul>
<p>The LIMES system offers a cost-effective solution for automatic hardness monitoring, which reliably issues an alarm as soon as a limit value is exceeded.</p>
<h3>How does the Reagent work?</h3>
<p>The LHV Reagents are liquid color reagents for automatic limit value monitoring with LIMES analyzers (LIMES Base, LIMES Plus). The device automatically takes a water sample, adds the Reagent and evaluates the color reaction. </p>
<p>In contrast to measuring range devices, the LIMES system does not provide exact measured values, but monitors whether the set limit value is adhered to. If the limit value is exceeded, an alarm is triggered &#8211; ideal for the reliable monitoring of water softening systems. </p>
<h3>Advantages of the LHV series</h3>
<ul class="feature-list">
<li>4 limit value levels from 0.1 to 7 °dH
<p style="text-indent: 30px; font-style: italic;">Suitable sensitivity for different applications</p>
</li>
<li>Specially developed for LIMES analyzers
<p style="text-indent: 30px; font-style: italic;">Optimum adjustment to the LIMES measuring principle</p>
</li>
<li>Reliable limit value monitoring around the clock
<p style="text-indent: 30px; font-style: italic;">Immediate alarm when limit values are exceeded</p>
</li>
<li>750 ml bottles &#8211; larger volume for longer service life
<p style="text-indent: 30px; font-style: italic;">Less frequent indicator changes</p>
</li>
<li>In-house production and individual batch calibration
<p style="text-indent: 30px; font-style: italic;">Consistently high quality &#8211; Made in Germany</p>
</li>
<li>24 months shelf life from production
<p style="text-indent: 30px; font-style: italic;">Cost-efficient stockpiling</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/total-value-lhv-series/">Total value LHV series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Total hardness H25 series</title>
		<link>https://rls-wacon.de/en/produkt/total-hardness-h25-series/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Wed, 11 Mar 2026 10:21:07 +0000</pubDate>
				<guid isPermaLink="false">https://rls-wacon.de/produkt/total-hardness-h25-series/</guid>

					<description><![CDATA[<p>Reagent total value H25 series What is the total value measured for? The total hardness (also water hardness) describes the concentration of alkaline earth ions dissolved in the water, in particular calcium and magnesium. Reliable hardness measurement is indispensable in many areas of water treatment: Boiler feed water and steam generation: Even small residues lead [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/total-hardness-h25-series/">Total hardness H25 series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Reagent total value H25 series</h2>
<h3>What is the total value measured for?</h3>
<p>The total hardness (also water hardness) describes the concentration of alkaline earth ions dissolved in the water, in particular calcium and magnesium. Reliable hardness measurement is indispensable in many areas of water treatment: </p>
<ul class="feature-list">
<li><strong>Boiler feed water and steam generation:</strong> Even small residues lead to limescale deposits (scaling), which can impair the heat transfer and cause damage to the system.</li>
<li><strong>Ion exchanger monitoring:</strong> Precise hardness measurement enables early detection of resin breakthroughs and needs-based regeneration.</li>
<li><strong>Reverse osmosis systems:</strong> Continuous control of permeate quality to protect downstream processes.</li>
<li><strong>Cooling water systems:</strong> Prevention of deposits and corrosion in cooling towers and heat exchangers.</li>
<li><strong>Drinking and process water:</strong> Monitoring of water quality in accordance with operational specifications.</li>
</ul>
<p>In industrial water treatment, precise and continuous monitoring of residual hardness is crucial for safe, efficient and economical plant operation.</p>
<h3>How does the Reagent work?</h3>
<p>The H25 Reagents are liquid color reagents for fully automatic water analysis with analyzers of the SYCON series from RLS Wacon. The measuring principle is based on a colorimetric reaction: </p>
<p>The analyzer automatically takes a water sample at freely configurable intervals, precisely doses the Reagent and measures the resulting coloration photometrically. The color intensity is directly proportional to the concentration of hardness in the water. </p>
<p>Fully automatic sampling and evaluation eliminates operating errors and ensures seamless 24/7 monitoring &#8211; even at measuring points that are difficult to access.</p>
<h3>Advantages of the H25 series</h3>
<ul class="feature-list">
<li>11 concentration levels from 0.02 to 10 °dH
<p style="text-indent: 30px; font-style: italic;">Precise selection for every measuring range and limit value</p>
</li>
<li>Fully automatic measurement with SYCON analyzers
<p style="text-indent: 30px; font-style: italic;">24/7 monitoring without manual intervention</p>
</li>
<li>Compatible with SYCON 2602, 2702, 2802 and SYCON BoB
<p style="text-indent: 30px; font-style: italic;">Flexible applications for limit value and measuring range devices</p>
</li>
<li>High-quality raw materials and our own recipe
<p style="text-indent: 30px; font-style: italic;">Manufactured by RLS Wacon &#8211; Made in Germany</p>
</li>
<li>In-house production and individual batch calibration
<p style="text-indent: 30px; font-style: italic;">Consistently high quality and precision with every delivery</p>
</li>
<li>24 months shelf life from production
<p style="text-indent: 30px; font-style: italic;">Cost-efficient stockpiling and flexible warehousing</p>
</li>
<li>Available as single bottle (500 ml) and value pack (4 × 500 ml)
<p style="text-indent: 30px; font-style: italic;">Economical container sizes for every need</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/total-hardness-h25-series/">Total hardness H25 series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SYCON BoB</title>
		<link>https://rls-wacon.de/en/produkt/sycon-bob/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Sat, 11 Mar 2023 21:13:13 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/sycon-bob/</guid>

					<description><![CDATA[<p>SYCON BoB &#8211; TÜV-certified analyzer for steam boiler systems Why is certified hardness monitoring required in the boiler house? Steam boiler systems place the highest demands on the quality of the feed water. Even the smallest amounts of residual hardness can lead to limescale deposits on the heating surfaces &#8211; resulting in overheating, loss of [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sycon-bob/">SYCON BoB</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 style="color: #0069b3;">SYCON BoB &#8211; TÜV-certified analyzer for steam boiler systems</h2>
<h3 style="color: #0069b3;">Why is certified hardness monitoring required in the boiler house?</h3>
<p>Steam boiler systems place the highest demands on the quality of the feed water. Even the smallest amounts of residual hardness can lead to limescale deposits on the heating surfaces &#8211; resulting in overheating, loss of performance and, in the worst case, boiler damage. <strong>VdTÜV Code of Practice WÜV 100 therefore requires continuous, automated monitoring of water hardness using certified devices &#8211; including the option of 72-hour unattended operation (BOB).</strong></p>
<h3 style="color: #0069b3;">What is the SYCON BoB?</h3>
<p>The SYCON BoB from RLS Wacon is a fully automatic online analyzer for monitoring the residual hardness in boiler feed water and returning condensate. It is certified in accordance with VdTÜV data sheet WÜV 100 and therefore fulfills the requirement for <strong>operation without supervision (BOB) for 72 hours</strong>.</p>
<p>The device is based on the proven SYCON platform, but is specially optimized for use in steam boilers: Pre-configured relays, an access code to protect against incorrect parameterization, a BOB probe for level monitoring of the Reagent and a shortened maintenance interval ensure maximum operational reliability.</p>
<h3 style="color: #0069b3;">How does the SYCON BoB work?</h3>
<p>The SYCON BoB works according to the <strong>colorimetric titration method</strong>. A water sample is automatically fed into the measuring chamber and the Reagent (H25-0.05 or H25-0.1) is added step by step. An optical sensor detects the color change and calculates the residual hardness of the water.</p>
<p>The integrated <strong>BOB sensor</strong> continuously monitors the fill level of the indicator bottle. As soon as the remaining content is sufficient for less than 72 hours of operation (approx. 12 % fill level), a BOB message is issued via relay 2 and the display. This ensures that the indicator supply is replenished in good time.</p>
<p>The analysis time is approx. 3 minutes with an indicator consumption of only 0.05 ml per analysis. Up to 10,000 analyses are possible with a 500 ml bottle.</p>
<h3 style="color: #0069b3;">Special features compared to the other SYCON models</h3>
<table class="h3-table">
<thead>
<tr>
<th style="background-color: #0069b3; color: #ffffff;">Feature</th>
<th style="background-color: #0069b3; color: #ffffff;">SYCON BoB</th>
<th style="background-color: #0069b3; color: #ffffff;">SYCON 2702/2802</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>TÜV certification (WÜV 100)</strong></td>
<td><strong>Yes</strong></td>
<td>&#8211;</td>
</tr>
<tr>
<td><strong>BOB probe (72h level monitoring)</strong></td>
<td><strong>Yes</strong></td>
<td>&#8211;</td>
</tr>
<tr>
<td><strong>Access code</strong></td>
<td><strong>Yes</strong></td>
<td>&#8211;</td>
</tr>
<tr>
<td><strong>Preconfigured relays</strong></td>
<td><strong>Yes (standardized wiring)</strong></td>
<td>Freely configurable</td>
</tr>
<tr>
<td><strong>Indicator selection</strong></td>
<td>H25-0.05 or H25-0.1 (fixed)</td>
<td>All H25/C25 Reagents</td>
</tr>
<tr>
<td><strong>Maintenance interval</strong></td>
<td><strong>12 months / 15,000 analyses</strong></td>
<td>24 months / 30,000 analyses</td>
</tr>
<tr>
<td><strong>External analysis start</strong></td>
<td>&#8211; (not possible)</td>
<td>Yes</td>
</tr>
</tbody>
</table>
<h3 style="color: #0069b3;">Advantages of the SYCON BoB</h3>
<ul class="feature-list">
<li>TÜV-certified according to VdTÜV data sheet WÜV 100
<p style="text-indent: 30px; font-style: italic;">Meets the legal requirements for the unattended operation of steam boiler systems</p>
</li>
<li>72-hour BOB operation with fill level monitoring
<p style="text-indent: 30px; font-style: italic;">The BOB probe signals in good time when the indicator supply needs to be replenished &#8211; can be extended to up to 144 hours with a longer measuring interval</p>
</li>
<li>Access code to protect against incorrect parameterization
<p style="text-indent: 30px; font-style: italic;">Locks access to critical settings during unattended operation</p>
</li>
<li>Preconfigured relays for standardized installation
<p style="text-indent: 30px; font-style: italic;">Limit value, BOB message, device fault, analysis active &#8211; Terminal diagram can be created in advance</p>
</li>
<li>RS485 interface with Modbus RTU
<p style="text-indent: 30px; font-style: italic;">Integration into the boiler control system and higher-level control systems</p>
</li>
<li>Analog output 0/4-20 mA
<p style="text-indent: 30px; font-style: italic;">Direct transmission of measured values to the system controller</p>
</li>
<li>Robust housing (IP54, IK08)
<p style="text-indent: 30px; font-style: italic;">Suitable for the harsh environmental conditions in the boiler house</p>
</li>
<li>Self-calibrating full color sensor
<p style="text-indent: 30px; font-style: italic;">No manual calibration &#8211; automatic compensation for ambient light, contamination and turbidity</p>
</li>
<li>Very low indicator consumption
<p style="text-indent: 30px; font-style: italic;">0.05 ml per analysis &#8211; up to 10,000 analyses per 500 ml bottle</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sycon-bob/">SYCON BoB</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SYCON 2702</title>
		<link>https://rls-wacon.de/en/produkt/sycon-2702/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Sat, 11 Mar 2023 21:13:12 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/sycon-2702/</guid>

					<description><![CDATA[<p>The SYCON 2702 is a titration device for optimum use in a water softening system or to protect a reverse osmosis system. The limit value to be monitored and the measuring interval can be freely programmed. In addition, two relays and a 4...20 mA interface enable connection to a variety of control systems. The measured values are stored on an internal SD card</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sycon-2702/">SYCON 2702</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 style="color: #0069b3;">SYCON 2702 &#8211; Titration device for measuring water hardness</h2>
<h3 style="color: #0069b3;">Why does water hardness need to be measured precisely?</h3>
<p>In many areas of water treatment, simple limit value monitoring is not sufficient. If you want to operate a water softener or reverse osmosis system economically and safely, you need exact water hardness measurements &#8211; not just a good/bad statement.  <strong>Only with a quantitative measured value can trends be identified, system performance assessed and regeneration cycles optimized.</strong></p>
<p>A gradual increase in residual hardness indicates a decreasing capacity of the ion exchanger &#8211; long before a breakthrough occurs. Similarly, the retention value of the membranes in a reverse osmosis system can only be reliably assessed if the permeate and feed hardness are quantitatively known. Precise measurement enables predictive maintenance and avoids unplanned downtime.  </p>
<h3 style="color: #0069b3;">What is the SYCON 2702?</h3>
<p>The SYCON 2702 from RLS Wacon is a fully automatic online titration device for the quantitative measurement of total hardness or carbonate hardness (acid capacity KS 4.3) in process and industrial water. In contrast to the SYCON 2602, which only provides a limit value statement, the SYCON 2702 determines the <strong>exact hardness value</strong> within the selected measuring range for each analysis. In addition, the device monitors a freely programmable limit value and signals whether it is exceeded or not via potential-free relay outputs.  </p>
<p>The SYCON 2702 has an analog current interface (0-20 mA or 4-20 mA) that can output the current measured value or the device status to a PLC or building management system. This makes it ideal for integration into higher-level control and monitoring systems. </p>
<h3 style="color: #0069b3;">How does the SYCON 2702 work?</h3>
<p>The SYCON 2702 works according to the principle of the <strong>colorimetric titration method</strong>. For each analysis, a water sample is automatically fed into the measuring cell. The Reagent (H25 series for total hardness or C25 series for carbonate hardness) is then dosed into the sample step by step. A maintenance-free RGB full color sensor in combination with a white high-power LED evaluates the progressive color change.   </p>
<p>The device calculates the exact hardness concentration of the water sample from the dosed amount of indicator. The measured values are shown on the graphic color display and automatically logged on an SD card. In addition, the current measured value can be transmitted to a PLC via the analog 4-20 mA output.  </p>
<p>After the measurement, the measuring cell is automatically flushed with line pressure. The color sensor automatically calibrates itself against ambient light, contamination and turbidity during each analysis. An integrated self-diagnosis with plausibility monitoring of the sensor data ensures additional operational safety. If limit values are exceeded, a control measurement can be repeated automatically to avoid false alarms caused by counter-ion effects.   </p>
<h3 style="color: #0069b3;">Measuring accuracy and reproducibility</h3>
<p>The SYCON 2702 achieves a measuring accuracy of <strong>± 5 % of the measuring range end value</strong> of the Reagent used with a repeatability of <strong>± 2.5 %</strong>. The analysis time is approx. 3 minutes depending on the degree of hardness and rinsing time. At least 10,000 analyses are possible per 500 ml bottle of Reagent &#8211; with a consumption of less than 0.05 ml per analysis for soft water. The measured values can be displayed in six units: °dH, °f, ppm CaCO₃, mmol/l, °e and °Zh.   </p>
<h3 style="color: #0069b3;">Advantages of the SYCON 2702</h3>
<ul class="feature-list">
<li>Exact determination of measured values by titration method
<p style="text-indent: 30px; font-style: italic;">Quantitative determination of water hardness &#8211; not just the limit value, but the actual hardness value</p>
</li>
<li>High measuring accuracy: ± 5 %, repeatability ± 2.5 %
<p style="text-indent: 30px; font-style: italic;">Reliable results for process monitoring and documentation</p>
</li>
<li>11 measuring ranges for total hardness (0.012-30 °dH), 4 for carbonate hardness (0.3-22.5 °dH)
<p style="text-indent: 30px; font-style: italic;">Wide selection of H25 and C25 Reagents for every application</p>
</li>
<li>Analog output 0/4-20 mA for PLC connection
<p style="text-indent: 30px; font-style: italic;">Measured value or status transmission to building management system, resolution &lt; 100 µA, max. 750 Ω load </p>
</li>
<li>Freely programmable limit value with control measurement
<p style="text-indent: 30px; font-style: italic;">Automatic repetition when limit values are exceeded to avoid false alarms</p>
</li>
<li>Self-calibrating full color sensor
<p style="text-indent: 30px; font-style: italic;">No manual calibration &#8211; automatic compensation of ambient light, contamination and turbidity</p>
</li>
<li>Very low indicator consumption
<p style="text-indent: 30px; font-style: italic;">Less than 0.05 ml per analysis &#8211; at least 10,000 analyses per 500 ml bottle</p>
</li>
<li>Fast analysis time of approx. 3 minutes
<p style="text-indent: 30px; font-style: italic;">More frequent measurement intervals possible than with the limit value method</p>
</li>
<li>Simple commissioning using the installation wizard
<p style="text-indent: 30px; font-style: italic;">Step-by-step guidance on the 9-language graphic display</p>
</li>
<li>Low maintenance effort
<p style="text-indent: 30px; font-style: italic;">Peristaltic pump technology and automatic rinsing &#8211; Maintenance set every 2 years or 30,000 analyses</p>
</li>
<li>SD card for complete measured value logging
<p style="text-indent: 30px; font-style: italic;">All analysis results with time stamp &#8211; can also be used for software updates</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sycon-2702/">SYCON 2702</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SYCON 2802</title>
		<link>https://rls-wacon.de/en/produkt/sycon-2802/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Sat, 11 Mar 2023 21:13:12 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/sycon-2802/</guid>

					<description><![CDATA[<p>SYCON 2802 &#8211; Premium titration device for water hardness with Modbus RTU Why the SYCON 2802? In complex water treatment plants, the highest demands are placed on process monitoring. In addition to the precise measurement of water hardness, measured values must be transmitted in real time to higher-level control systems (PLC, SCADA, building management systems). [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sycon-2802/">SYCON 2802</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 style="color: #0069b3;">SYCON 2802 &#8211; Premium titration device for water hardness with Modbus RTU</h2>
<h3 style="color: #0069b3;">Why the SYCON 2802?</h3>
<p>In complex water treatment plants, the highest demands are placed on process monitoring. In addition to the precise measurement of water hardness, measured values must be transmitted in real time to higher-level control systems (PLC, SCADA, building management systems). <strong>Several limit values enable a differentiated response &#8211; for example, a pre-alarm if slightly exceeded and a safety shutdown if critical values are reached.</strong></p>
<p>The SYCON 2802 is the flagship of the SYCON series and combines all the functions of the SYCON 2702 with additional interfaces and control options. It is the first choice for demanding industrial applications where seamless integration into plant automation and complete process documentation are required.</p>
<h3 style="color: #0069b3;">What is the SYCON 2802?</h3>
<p>The SYCON 2802 from RLS Wacon is a fully automatic online titration device for the quantitative measurement of total hardness or carbonate hardness (acid capacity KS 4.3) in process and industrial water. Compared to the SYCON 2702, it offers two additional relay outputs (4 in total), an RS485 interface with Modbus RTU protocol, a second digital input and a second, freely programmable limit value.</p>
<p>The second limit value enables differentiated monitoring: for example, limit value 1 can be configured as a pre-alarm and limit value 2 as the main alarm. Alternatively, a water overlap can be monitored with two limit values &#8211; with a lower and an upper threshold value for the desired mixing hardness.</p>
<h3 style="color: #0069b3;">How does the SYCON 2802 work?</h3>
<p>The measuring principle is identical to the SYCON 2702: <strong>colorimetric titration method</strong>. A water sample is automatically fed into the measuring cell and the Reagent (H25 series or C25 series) is added step by step. The maintenance-free RGB full color sensor evaluates the color change and calculates the exact hardness concentration. The analysis time is approx. 3 minutes and the indicator consumption is less than 0.05 ml per analysis.</p>
<p>The decisive difference lies in the extended interfaces: Via the RS485 interface with Modbus RTU protocol, measured values and device parameters can be queried directly from a PLC. The analog output (0/4-20 mA) is also available. Four relay outputs offer maximum flexibility for signaling and system control.</p>
<h3 style="color: #0069b3;">Extended functions compared to the SYCON 2702</h3>
<table class="h3-table">
<thead>
<tr>
<th style="background-color: #0069b3; color: #ffffff;">Function</th>
<th style="background-color: #0069b3; color: #ffffff;">SYCON 2702</th>
<th style="background-color: #0069b3; color: #ffffff;">SYCON 2802</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>Relay outputs</strong></td>
<td>2</td>
<td><strong>4</strong></td>
</tr>
<tr>
<td><strong>Programmable limit values</strong></td>
<td>1</td>
<td><strong>2</strong></td>
</tr>
<tr>
<td><strong>Digital inputs</strong></td>
<td>1</td>
<td><strong>2</strong></td>
</tr>
<tr>
<td><strong>RS485 / Modbus RTU</strong></td>
<td>&#8211;</td>
<td><strong>Yes</strong></td>
</tr>
<tr>
<td><strong>Cooling water valve control</strong></td>
<td>&#8211;</td>
<td><strong>Yes (via relay 4)</strong></td>
</tr>
<tr>
<td><strong>Analog output 0/4-20 mA</strong></td>
<td>Yes</td>
<td>Yes</td>
</tr>
</tbody>
</table>
<h3 style="color: #0069b3;">Advantages of the SYCON 2802</h3>
<ul class="feature-list">
<li>Exact determination of measured values by titration method
<p style="text-indent: 30px; font-style: italic;">Quantitative determination of water hardness with ± 5 % accuracy and ± 2.5 % repeatability</p>
</li>
<li>RS485 interface with Modbus RTU
<p style="text-indent: 30px; font-style: italic;">Direct query of measured values and device parameters by a PLC &#8211; seamless integration into the system automation</p>
</li>
<li>Two freely programmable limit values
<p style="text-indent: 30px; font-style: italic;">Pre-alarm and main alarm or monitoring of a water overlap with lower and upper threshold value</p>
</li>
<li>4 potential-free relay outputs
<p style="text-indent: 30px; font-style: italic;">Limit value 1, limit value 2 / indicator level, device fault, analysis active / cooling water valve</p>
</li>
<li>Analog output 0/4-20 mA in addition to Modbus
<p style="text-indent: 30px; font-style: italic;">Parallel measured value output via analog and digital interface</p>
</li>
<li>2 digital inputs
<p style="text-indent: 30px; font-style: italic;">External analysis start, water meter, flow monitor, interval reset, remote reset &#8211; flexibly configurable</p>
</li>
<li>Control of an external cooling water valve
<p style="text-indent: 30px; font-style: italic;">Relay 4 can be configured to automatically control a sample cooler valve</p>
</li>
<li>Self-calibrating full color sensor
<p style="text-indent: 30px; font-style: italic;">No manual calibration &#8211; automatic compensation of ambient light, contamination and turbidity</p>
</li>
<li>Very low indicator consumption
<p style="text-indent: 30px; font-style: italic;">Less than 0.05 ml per analysis &#8211; at least 10,000 analyses per 500 ml bottle</p>
</li>
<li>9-language graphic display with SD card
<p style="text-indent: 30px; font-style: italic;">Complete logging, installation wizard, software updates via SD card</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sycon-2802/">SYCON 2802</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SYCON 2602</title>
		<link>https://rls-wacon.de/en/produkt/sycon-2602/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Sat, 11 Mar 2023 21:13:11 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/sycon-2602/</guid>

					<description><![CDATA[<p>SYCON 2602 &#8211; Limit value monitoring for water hardness and carbonate hardness Why does water hardness need to be monitored? In water treatment, reliable monitoring of water hardness is a decisive factor for the protection of downstream systems and processes. Softening systems that work on an ion exchanger basis must be regenerated in good time [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sycon-2602/">SYCON 2602</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 style="color: #0069b3;">SYCON 2602 &#8211; Limit value monitoring for water hardness and carbonate hardness</h2>
<h3 style="color: #0069b3;">Why does water hardness need to be monitored?</h3>
<p>In water treatment, reliable monitoring of water hardness is a decisive factor for the protection of downstream systems and processes. Softening systems that work on an ion exchanger basis must be regenerated in good time before hardness-forming ions (calcium and magnesium) break through the exchanger. <strong>A breakthrough can lead to scaling in pipes, heat exchangers and steam boilers</strong> &#8211; with considerable consequential costs due to energy losses, production downtime and costly cleaning. </p>
<p>Limit value monitoring is also essential for the protection of reverse osmosis systems: if the permissible hardness in the feed water is exceeded, there is a risk of irreversible membrane damage due to scaling. The early detection of a hardness breakthrough enables immediate intervention &#8211; whether through a demand-controlled regeneration trigger or a safety shutdown of the downstream system. </p>
<h3 style="color: #0069b3;">What is the SYCON 2602?</h3>
<p>The SYCON 2602 from RLS Wacon is a fully automatic online analyzer for limit value monitoring of total hardness or carbonate hardness (acid capacity KS 4.3) in process and industrial water. As an entry-level model in the SYCON series, it offers a reliable pass/fail assessment of water quality: the device checks whether the limit value set by the Reagent used is met or exceeded for each analysis and reports the result via up to three potential-free relay outputs. </p>
<p>In addition to the limit value status, the graphic color display also shows information such as analysis interval, indicator supply, device status and error history. The menu navigation is available in nine languages: German, English, French, Italian, Spanish, Russian, Polish, Dutch and Danish. </p>
<h3 style="color: #0069b3;">How does the SYCON 2602 work?</h3>
<p>The SYCON 2602 works according to the principle of the <strong>colorimetric limit value method</strong>. For each analysis, a water sample is automatically fed into the measuring cell and the respective Reagent (H25 series for total hardness or C25 series for carbonate hardness) is added. A maintenance-free RGB full color sensor in combination with a white high-power LED evaluates the color change of the sample.  </p>
<p>If the hardness of the sample water is below the Reagent limit value, the sample discolors &#8211; the result is &#8220;GOOD&#8221;. If there is no discoloration or it is too weak, the limit value is reported as exceeded (&#8220;BAD&#8221;) and relay 1 switches. After the measurement, the measuring cell is automatically flushed with line pressure so that no indicator residues affect the next analysis.  </p>
<p>The color sensor automatically calibrates itself against ambient light, contamination and turbidity of the water sample during each measurement. An integrated self-diagnosis with plausibility monitoring of the sensor data ensures additional operational reliability. All measurement results are automatically logged on an SD card.  </p>
<h3 style="color: #0069b3;">BOB functionality &#8211; operation without supervision</h3>
<p>The SYCON 2602 automatically monitors the indicator supply and signals via the configurable relay output 3 when the fill level is low. The BOB function (unattended operation) enables continuous, unattended operation for at least 72 hours &#8211; with an indicator consumption of less than 0.1 ml per analysis and at least 5,000 analyses per 500 ml bottle, operation is possible for weeks without refilling. </p>
<h3 style="color: #0069b3;">Advantages of the SYCON 2602</h3>
<ul class="feature-list">
<li>Reliable limit value monitoring for total hardness and carbonate hardness
<p style="text-indent: 30px; font-style: italic;">Automatic good/bad evaluation with immediate alarm via relay output</p>
</li>
<li>11 limit values for total hardness, 4 for carbonate hardness
<p style="text-indent: 30px; font-style: italic;">From 0.02 to 10 °dH (total hardness) and 1 to 3 °dH (carbonate hardness) &#8211; suitable for every application</p>
</li>
<li>Self-calibrating full color sensor
<p style="text-indent: 30px; font-style: italic;">No manual calibration required &#8211; automatic compensation for ambient light, contamination and turbidity</p>
</li>
<li>Very low indicator consumption
<p style="text-indent: 30px; font-style: italic;">Less than 0.1 ml per analysis &#8211; at least 5,000 analyses per 500 ml bottle</p>
</li>
<li>Simple commissioning using the installation wizard
<p style="text-indent: 30px; font-style: italic;">Step-by-step guidance on the graphic display &#8211; even without prior knowledge</p>
</li>
<li>3 potential-free relay outputs
<p style="text-indent: 30px; font-style: italic;">Limit value alarm, device fault and analysis active / BOB message / indicator fill level &#8211; freely configurable</p>
</li>
<li>Low maintenance effort
<p style="text-indent: 30px; font-style: italic;">Peristaltic pump technology and automatic flushing of the measuring cell with line pressure &#8211; Maintenance set every 2 years or 30,000 analyses</p>
</li>
<li>9-language graphic display
<p style="text-indent: 30px; font-style: italic;">DE, EN, FR, IT, ES, RU, PL, NL, DK &#8211; ideal for international use</p>
</li>
<li>SD card for measured value logging
<p style="text-indent: 30px; font-style: italic;">Complete documentation of all analysis results with time stamp</p>
</li>
<li>Compact design &#8211; wall bracket or housing
<p style="text-indent: 30px; font-style: italic;">274 × 275 × 129 mm (wall bracket IP43) or 332 × 345 × 190 mm (housing IP54)</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/sycon-2602/">SYCON 2602</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LIMESBASE</title>
		<link>https://rls-wacon.de/en/produkt/limesbase/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Sat, 11 Mar 2023 21:13:05 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/limesbase/</guid>

					<description><![CDATA[<p>The LIMESBASE is the most affordable model in the Limes series for getting started with online water hardness monitoring. The Limes hardness monitoring devices enable cost-effective monitoring of reverse osmosis systems with reliable chemical analysis.</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/limesbase/">LIMESBASE</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul>
<li>Reliable and accurate monitoring of water hardness using a laboratory-calibrated indicator.</li>
<li>Monitoring of a defined limit value determined by the LHV indicator used.</li>
<li>No delayed response behavior compared to a swelling resin sensor.</li>
<li>No calibration and no drift effects compared to an electrode measurement.</li>
<li>No wear or regeneration of the sensor necessary.</li>
<li>Separate connection cables for power supply, relay and input contact.</li>
<li>Status display with four LEDs for limit value compliance, analysis status, device status and pending service.</li>
</ul>
<h3>Product information LIMESBASE</h3>
<ul>
<li>LED status display</li>
<li>language-neutral</li>
<li>First value suppression to prevent false alarms</li>
<li>Automatic interval operation: limit value check of the system every 10 minutes</li>
<li>Connections:
<ul>
<li>2 potential-free outputs:
<ul>
<li>Limit value exceeded</li>
<li>Device fault</li>
</ul>
</li>
</ul>
</li>
<li>Easy to upgrade to LIMESPLUS if required</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/limesbase/">LIMESBASE</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LIMESPLUS</title>
		<link>https://rls-wacon.de/en/produkt/limesplus/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Sat, 11 Mar 2023 21:13:05 +0000</pubDate>
				<guid isPermaLink="false">https://new.rls-wacon.de/produkt/limesplus/</guid>

					<description><![CDATA[<p>The Limes hardness monitoring devices enable cost-effective monitoring of reverse osmosis systems with reliable chemical analysis.</p>
<p>&#160;</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/limesplus/">LIMESPLUS</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul>
<li>Reliable and accurate monitoring of water hardness using a laboratory-calibrated indicator.</li>
<li>Monitoring of a defined limit value determined by the LHV indicator used.</li>
<li>No delayed response behavior compared to a swelling resin sensor.</li>
<li>No calibration and no drift effects compared to an electrode measurement.</li>
<li>No wear or regeneration of the sensor necessary.</li>
<li>Separate connection cables for power supply, relay and input contact.</li>
<li>Status display with four LEDs for limit value compliance, analysis status, device status and pending service.</li>
</ul>
<h3>Product information LIMESPLUS</h3>
<ul>
<li>LED status display</li>
<li>language-neutral</li>
<li>First value suppression to prevent false alarms</li>
<li>Flushing duration adjustable to the supply line length</li>
<li>Automatic interval operation: limit value control of the system at adjustable intervals of 10, 20 or 30 minutes</li>
<li>Connections:
<ul>
<li>2 potential-free outputs:
<ul>
<li>Limit value exceeded</li>
<li>Device fault</li>
</ul>
</li>
<li>Input contact for potential-free switch
<ul>
<li>External analysis start</li>
<li>Pausing the internal interval using a flow switch</li>
</ul>
</li>
</ul>
</li>
<li>Diagnostic program for testing the assemblies</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/limesplus/">LIMESPLUS</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
