<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Reagents Archive - RLS Wacon analytics</title>
	<atom:link href="https://rls-wacon.de/en/product-category/water/online-analytics/reagents/feed/" rel="self" type="application/rss+xml" />
	<link>https://rls-wacon.de/product-category/wasser/online-analytik/indikatoren/</link>
	<description>Experts for water monitoring</description>
	<lastBuildDate>Thu, 16 Apr 2026 13:32:48 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://rls-wacon.de/wp-content/uploads/2024/04/cropped-Kreis_logo_gross-32x32.png</url>
	<title>Reagents Archive - RLS Wacon analytics</title>
	<link>https://rls-wacon.de/product-category/wasser/online-analytik/indikatoren/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Total value LHV series</title>
		<link>https://rls-wacon.de/en/produkt/total-value-lhv-series/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Tue, 17 Mar 2026 14:56:49 +0000</pubDate>
				<guid isPermaLink="false">https://rls-wacon.de/produkt/total-value-lhv-series/</guid>

					<description><![CDATA[<p>Reagent total hardness LHV series Why is the total hardness measured with LHV? The LHV series has been specially developed for total hardness measurement with analyzers from the LIMES series. The LIMES devices work purely as limit value monitors and continuously monitor whether a defined hardness limit value is exceeded or not reached. Typical areas [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/total-value-lhv-series/">Total value LHV series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Reagent total hardness LHV series</h2>
<h3>Why is the total hardness measured with LHV?</h3>
<p>The LHV series has been specially developed for total hardness measurement with analyzers from the LIMES series. The LIMES devices work purely as limit value monitors and continuously monitor whether a defined hardness limit value is exceeded or not reached. </p>
<p>Typical areas of application:</p>
<ul class="feature-list">
<li><strong>Softening systems:</strong> Monitoring of the drain water after ion exchangers &#8211; immediate detection of resin breakthroughs.</li>
<li><strong>Boiler feed water:</strong> Ensure that the required residual hardness is maintained in order to avoid limescale deposits.</li>
<li><strong>Reverse osmosis systems:</strong> Continuous control of the permeate quality.</li>
<li><strong>Drinking water treatment:</strong> Automated quality assurance of water hardness.</li>
</ul>
<p>The LIMES system offers a cost-effective solution for automatic hardness monitoring, which reliably issues an alarm as soon as a limit value is exceeded.</p>
<h3>How does the Reagent work?</h3>
<p>The LHV Reagents are liquid color reagents for automatic limit value monitoring with LIMES analyzers (LIMES Base, LIMES Plus). The device automatically takes a water sample, adds the Reagent and evaluates the color reaction. </p>
<p>In contrast to measuring range devices, the LIMES system does not provide exact measured values, but monitors whether the set limit value is adhered to. If the limit value is exceeded, an alarm is triggered &#8211; ideal for the reliable monitoring of water softening systems. </p>
<h3>Advantages of the LHV series</h3>
<ul class="feature-list">
<li>4 limit value levels from 0.1 to 7 °dH
<p style="text-indent: 30px; font-style: italic;">Suitable sensitivity for different applications</p>
</li>
<li>Specially developed for LIMES analyzers
<p style="text-indent: 30px; font-style: italic;">Optimum adjustment to the LIMES measuring principle</p>
</li>
<li>Reliable limit value monitoring around the clock
<p style="text-indent: 30px; font-style: italic;">Immediate alarm when limit values are exceeded</p>
</li>
<li>750 ml bottles &#8211; larger volume for longer service life
<p style="text-indent: 30px; font-style: italic;">Less frequent indicator changes</p>
</li>
<li>In-house production and individual batch calibration
<p style="text-indent: 30px; font-style: italic;">Consistently high quality &#8211; Made in Germany</p>
</li>
<li>24 months shelf life from production
<p style="text-indent: 30px; font-style: italic;">Cost-efficient stockpiling</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/total-value-lhv-series/">Total value LHV series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Silicate</title>
		<link>https://rls-wacon.de/en/produkt/silicate/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Tue, 17 Mar 2026 13:34:26 +0000</pubDate>
				<guid isPermaLink="false">https://rls-wacon.de/produkt/silicate/</guid>

					<description><![CDATA[<p>Reagent silicate What is silicate measured for? Silicate (SiO₂) is a dissolved ingredient that occurs in almost all natural waters. Monitoring the silicate concentration is particularly important in the following areas: Power plants and steam generation: At high temperatures and pressures, silicate forms extremely hard, glass-like deposits on turbine blades and in steam pipes. These [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/silicate/">Silicate</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Reagent silicate</h2>
<h3>What is silicate measured for?</h3>
<p>Silicate (SiO₂) is a dissolved ingredient that occurs in almost all natural waters. Monitoring the silicate concentration is particularly important in the following areas: </p>
<ul class="feature-list">
<li><strong>Power plants and steam generation:</strong> At high temperatures and pressures, silicate forms extremely hard, glass-like deposits on turbine blades and in steam pipes. These deposits are almost impossible to remove and lead to considerable efficiency losses. </li>
<li><strong>Boiler feed water:</strong> Even low silicate concentrations can cause damage in the high-pressure range. Typical limit values are in the range of a few µg/l. </li>
<li><strong>Reverse osmosis systems:</strong> Silicate can irreversibly foul membranes (silica fouling). Monitoring the permeate protects against costly membrane damage. </li>
<li><strong>Mixed bed ion exchanger:</strong> Control of the exchange capacity &#8211; silicate is often one of the first parameters to break through during depletion.</li>
</ul>
<h3>How does the Reagent work?</h3>
<p>The silicate Reagents consist of a reagent set with several components for fully automatic silicate determination with the SYCON SiO₂ analyzer. The device automatically takes a water sample, adds the reagents in the correct order and quantity and measures the coloration photometrically. </p>
<p>Two measuring ranges are available: Low Range (0.02-10 mg/l) for the trace range and High Range (10-150 mg/l) for higher concentrations.</p>
<h3>Advantages of silicate Reagents</h3>
<ul class="feature-list">
<li>Two measuring ranges: Low Range (0.02-10 mg/l) and High Range (10-150 mg/l)
<p style="text-indent: 30px; font-style: italic;">Covered from trace levels to high concentrations</p>
</li>
<li>Fully automatic measurement with the SYCON SiO₂
<p style="text-indent: 30px; font-style: italic;">Continuous 24/7 monitoring of critical processes</p>
</li>
<li>Reagent sets with coordinated components
<p style="text-indent: 30px; font-style: italic;">Optimal reaction conditions for precise results</p>
</li>
<li>High-quality raw materials and our own recipe
<p style="text-indent: 30px; font-style: italic;">Manufactured by RLS Wacon &#8211; Made in Germany</p>
</li>
<li>Single batch calibration
<p style="text-indent: 30px; font-style: italic;">Consistently high precision with every delivery</p>
</li>
<li>24 months shelf life
<p style="text-indent: 30px; font-style: italic;">Cost-efficient stockpiling</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/silicate/">Silicate</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>p-value P25 series</title>
		<link>https://rls-wacon.de/en/produkt/p-value-p25-series/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Tue, 17 Mar 2026 13:31:56 +0000</pubDate>
				<guid isPermaLink="false">https://rls-wacon.de/produkt/p-value-p25-series/</guid>

					<description><![CDATA[<p>Reagent p-value P25 series What is the p-value measured for? The p-value (also acid capacity up to pH 8.2 or m-value/alkalinity) describes the concentration of hydroxide and carbonate ions in the water. It is a decisive parameter in boiler water and cooling water chemistry: Boiler water: The p-value is a key parameter for correct alkalization. [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/p-value-p25-series/">p-value P25 series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Reagent p-value P25 series</h2>
<h3>What is the p-value measured for?</h3>
<p>The p-value (also acid capacity up to pH 8.2 or m-value/alkalinity) describes the concentration of hydroxide and carbonate ions in the water. It is a decisive parameter in boiler water and cooling water chemistry: </p>
<ul class="feature-list">
<li><strong>Boiler water:</strong> The p-value is a key parameter for correct alkalization. Too low values lead to corrosion, too high values can cause foaming and overflow problems. </li>
<li><strong>Steam and condensate systems:</strong> Monitoring the p-value ensures that the alkalization remains in the optimum range.</li>
<li><strong>Cooling water systems:</strong> The p-value influences the corrosion and limescale separation behavior.</li>
<li><strong>Industrial process water:</strong> control of water chemistry in closed circuits.</li>
</ul>
<h3>How does the Reagent work?</h3>
<p>The P25 Reagents are liquid color reagents for fully automated p-value determination with the SYCON P analyzer. The device automatically takes a water sample, precisely doses the Reagent and measures the resulting coloration photometrically. </p>
<p>Two measuring ranges are available: P25-5 for the low range (0.2-5.0 mmol/l) and P25-20 for higher concentrations (0.8-20.0 mmol/l).</p>
<h3>Advantages of the P25 series</h3>
<ul class="feature-list">
<li>Two measuring ranges: P25-5 (0.2-5 mmol/l) and P25-20 (0.8-20 mmol/l)
<p style="text-indent: 30px; font-style: italic;">Precise measurement over a wide concentration range</p>
</li>
<li>Fully automatic measurement with the SYCON P
<p style="text-indent: 30px; font-style: italic;">Continuous 24/7 monitoring of boiler water chemistry</p>
</li>
<li>High-quality raw materials and our own recipe
<p style="text-indent: 30px; font-style: italic;">Manufactured by RLS Wacon &#8211; Made in Germany</p>
</li>
<li>Single batch calibration
<p style="text-indent: 30px; font-style: italic;">Consistently high precision with every delivery</p>
</li>
<li>Available as single bottle (500 ml) and value pack (4 × 500 ml)
<p style="text-indent: 30px; font-style: italic;">Economical container sizes for every need</p>
</li>
<li>24 months shelf life
<p style="text-indent: 30px; font-style: italic;">Cost-efficient stockpiling</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/p-value-p25-series/">p-value P25 series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Iron Fe series</title>
		<link>https://rls-wacon.de/en/produkt/iron-fe-series/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Tue, 17 Mar 2026 13:29:35 +0000</pubDate>
				<guid isPermaLink="false">https://rls-wacon.de/produkt/iron-fe-series/</guid>

					<description><![CDATA[<p>Reagent iron Fe series What is iron measured for? Iron (Fe) is one of the most common elements in water and can be of natural origin or enter the water through corrosion of pipes. Monitoring the iron concentration is essential in many areas: Drinking water treatment: The limit value for drinking water is 0.2 mg/l [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/iron-fe-series/">Iron Fe series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Reagent iron Fe series</h2>
<h3>What is iron measured for?</h3>
<p>Iron (Fe) is one of the most common elements in water and can be of natural origin or enter the water through corrosion of pipes. Monitoring the iron concentration is essential in many areas: </p>
<ul class="feature-list">
<li><strong>Drinking water treatment:</strong> The limit value for drinking water is 0.2 mg/l Fe (Drinking Water Ordinance). Elevated iron levels lead to undesirable discoloration and a metallic taste. </li>
<li><strong>Boiler feed water:</strong> Iron causes deposits in boilers and steam systems, which can lead to corrosion damage.</li>
<li><strong>Cooling water:</strong> Iron deposits reduce the heat transfer capacity and clog pipes.</li>
<li><strong>Waterworks:</strong> monitoring of iron removal &#8211; checking whether iron filters are working properly.</li>
</ul>
<h3>How does the Reagent work?</h3>
<p>The Fe Reagents are liquid color reagents for fully automatic iron determination with the SYCON Fe analyzer. The device automatically takes a water sample, adds the Reagent and measures the coloration photometrically. </p>
<p>Two measuring ranges are available: The LRS (Low Range) Reagent for low concentrations (0.01-0.5 mg/l) and the HRS (High Range) Reagent for higher concentrations (0.2-6.0 mg/l).</p>
<h3>Advantages of the Fe series</h3>
<ul class="feature-list">
<li>Two measuring ranges: LRS (0.01-0.5 mg/l) and HRS (0.2-6.0 mg/l)
<p style="text-indent: 30px; font-style: italic;">Precise measurement both in the trace range and at higher concentrations</p>
</li>
<li>Freely configurable limit values on the device
<p style="text-indent: 30px; font-style: italic;">Limit values: 0.03 / 0.05 / 0.1 / 0.2 / 0.3 / 0.4 / 0.5 / 0.6 mg/l</p>
</li>
<li>Fully automatic measurement with the SYCON Fe
<p style="text-indent: 30px; font-style: italic;">Continuous 24/7 monitoring</p>
</li>
<li>High-quality raw materials and our own recipe
<p style="text-indent: 30px; font-style: italic;">Manufactured by RLS Wacon &#8211; Made in Germany</p>
</li>
<li>Individual batch calibration for consistent quality
<p style="text-indent: 30px; font-style: italic;">Highest precision with every delivery</p>
</li>
<li>24 months shelf life
<p style="text-indent: 30px; font-style: italic;">Cost-efficient stockpiling</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/iron-fe-series/">Iron Fe series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Carbonate C25 series</title>
		<link>https://rls-wacon.de/en/produkt/carbonate-c25-series/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Tue, 17 Mar 2026 11:27:47 +0000</pubDate>
				<guid isPermaLink="false">https://rls-wacon.de/produkt/carbonate-c25-series/</guid>

					<description><![CDATA[<p>Reagent carbonate values C25 series What is the carbonate value measured for? The carbonate value (also known as the temporal value) describes the proportion of the water value that is caused by hydrogen carbonate ions (HCO₃-). Monitoring carbonate levels is crucial in many areas of water treatment: Cooling water systems: The carbonate values directly influence [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/carbonate-c25-series/">Carbonate C25 series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Reagent carbonate values C25 series</h2>
<h3>What is the carbonate value measured for?</h3>
<p>The carbonate value (also known as the temporal value) describes the proportion of the water value that is caused by hydrogen carbonate ions (HCO₃-). Monitoring carbonate levels is crucial in many areas of water treatment: </p>
<ul class="feature-list">
<li><strong>Cooling water systems:</strong> The carbonate values directly influence the lime-carbonic acid balance. Excessive values lead to lime precipitation in cooling towers and heat exchangers. </li>
<li><strong>Boiler feed water:</strong> Hydrogen carbonate decomposes to carbonate and CO₂ during heating, which leads to corrosion in the steam/condensate system.</li>
<li><strong>Swimming pool and bathing water:</strong> The carbonate value is an important parameter for the water balance according to Langelier or the LSI index.</li>
<li><strong>Drinking water:</strong> The carbonate content influences the taste and the tendency for limescale formation in pipes.</li>
</ul>
<h3>How does the Reagent work?</h3>
<p>The C25 Reagents are liquid color reagents for fully automatic water analysis with SYCON analyzers. The SYCON device automatically takes a water sample, precisely doses the Reagent and measures the resulting coloration photometrically. </p>
<p>Depending on the device mode, the system operates as a limit value monitor (SYCON 2602) or as a measuring range device (SYCON 2702, 2802) with continuous measured value output.</p>
<h3>Advantages of the C25 series</h3>
<ul class="feature-list">
<li>4 concentration levels from 1 to 3 °dKH
<p style="text-indent: 30px; font-style: italic;">Customized selection for different applications</p>
</li>
<li>Limit value and measuring range operation possible
<p style="text-indent: 30px; font-style: italic;">Flexible use with SYCON 2602, 2702 and 2802</p>
</li>
<li>Fully automatic measurement around the clock
<p style="text-indent: 30px; font-style: italic;">Leak-free monitoring without manual intervention</p>
</li>
<li>High-quality raw materials and our own recipe
<p style="text-indent: 30px; font-style: italic;">Manufactured by RLS Wacon &#8211; Made in Germany</p>
</li>
<li>Single batch calibration
<p style="text-indent: 30px; font-style: italic;">Consistently high precision with every delivery</p>
</li>
<li>24 months shelf life, 500 ml and 4-pack available
<p style="text-indent: 30px; font-style: italic;">Economical container sizes for every need</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/carbonate-c25-series/">Carbonate C25 series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Total hardness H25 series</title>
		<link>https://rls-wacon.de/en/produkt/total-hardness-h25-series/</link>
		
		<dc:creator><![CDATA[Stefano Russo]]></dc:creator>
		<pubDate>Wed, 11 Mar 2026 10:21:07 +0000</pubDate>
				<guid isPermaLink="false">https://rls-wacon.de/produkt/total-hardness-h25-series/</guid>

					<description><![CDATA[<p>Reagent total value H25 series What is the total value measured for? The total hardness (also water hardness) describes the concentration of alkaline earth ions dissolved in the water, in particular calcium and magnesium. Reliable hardness measurement is indispensable in many areas of water treatment: Boiler feed water and steam generation: Even small residues lead [&#8230;]</p>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/total-hardness-h25-series/">Total hardness H25 series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Reagent total value H25 series</h2>
<h3>What is the total value measured for?</h3>
<p>The total hardness (also water hardness) describes the concentration of alkaline earth ions dissolved in the water, in particular calcium and magnesium. Reliable hardness measurement is indispensable in many areas of water treatment: </p>
<ul class="feature-list">
<li><strong>Boiler feed water and steam generation:</strong> Even small residues lead to limescale deposits (scaling), which can impair the heat transfer and cause damage to the system.</li>
<li><strong>Ion exchanger monitoring:</strong> Precise hardness measurement enables early detection of resin breakthroughs and needs-based regeneration.</li>
<li><strong>Reverse osmosis systems:</strong> Continuous control of permeate quality to protect downstream processes.</li>
<li><strong>Cooling water systems:</strong> Prevention of deposits and corrosion in cooling towers and heat exchangers.</li>
<li><strong>Drinking and process water:</strong> Monitoring of water quality in accordance with operational specifications.</li>
</ul>
<p>In industrial water treatment, precise and continuous monitoring of residual hardness is crucial for safe, efficient and economical plant operation.</p>
<h3>How does the Reagent work?</h3>
<p>The H25 Reagents are liquid color reagents for fully automatic water analysis with analyzers of the SYCON series from RLS Wacon. The measuring principle is based on a colorimetric reaction: </p>
<p>The analyzer automatically takes a water sample at freely configurable intervals, precisely doses the Reagent and measures the resulting coloration photometrically. The color intensity is directly proportional to the concentration of hardness in the water. </p>
<p>Fully automatic sampling and evaluation eliminates operating errors and ensures seamless 24/7 monitoring &#8211; even at measuring points that are difficult to access.</p>
<h3>Advantages of the H25 series</h3>
<ul class="feature-list">
<li>11 concentration levels from 0.02 to 10 °dH
<p style="text-indent: 30px; font-style: italic;">Precise selection for every measuring range and limit value</p>
</li>
<li>Fully automatic measurement with SYCON analyzers
<p style="text-indent: 30px; font-style: italic;">24/7 monitoring without manual intervention</p>
</li>
<li>Compatible with SYCON 2602, 2702, 2802 and SYCON BoB
<p style="text-indent: 30px; font-style: italic;">Flexible applications for limit value and measuring range devices</p>
</li>
<li>High-quality raw materials and our own recipe
<p style="text-indent: 30px; font-style: italic;">Manufactured by RLS Wacon &#8211; Made in Germany</p>
</li>
<li>In-house production and individual batch calibration
<p style="text-indent: 30px; font-style: italic;">Consistently high quality and precision with every delivery</p>
</li>
<li>24 months shelf life from production
<p style="text-indent: 30px; font-style: italic;">Cost-efficient stockpiling and flexible warehousing</p>
</li>
<li>Available as single bottle (500 ml) and value pack (4 × 500 ml)
<p style="text-indent: 30px; font-style: italic;">Economical container sizes for every need</p>
</li>
</ul>
<p>Der Beitrag <a href="https://rls-wacon.de/en/produkt/total-hardness-h25-series/">Total hardness H25 series</a> erschien zuerst auf <a href="https://rls-wacon.de/en/">RLS Wacon analytics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
