Private customers can also find our range in our partner store Ampha-Analyse.
Reagent for CALDUR® Ascorbic acid – Colorimetric:
See also:
CALDUR® Ascorbic acid test kit – Colorimetric
What is ascorbic acid measured for?
Ascorbic acid (vitamin C, C₆H₈O₆) is used in water treatment as an oxygen binding and reducing agent. In the food industry, ascorbic acid is used as an antioxidant and preservative to prevent the oxidation of food and extend its shelf life.
In steam boilers and closed cooling systems, ascorbic acid is used in a similar way to Sulfite to bind dissolved oxygen in order to prevent corrosion. Ascorbic acid reacts with oxygen to form dehydroascorbic acid and thus protects pipes and system components from oxygen corrosion.
The optimum ascorbic acid concentration in technical applications is typically 10-50 mg/l C₆H₈O₆. In the food industry, the concentrations vary greatly depending on the application and must be controlled on a product-specific basis.
How does the test set work?
The CALDUR® Ascorbic Acid Test Set – Colorimetric is based on the ferrozine method. Ascorbic acid reduces iron(III) to iron(II), which then forms a violet color complex with ferrozine. After adding two reagents to the water sample, a characteristic violet color develops within 3 minutes, the intensity of which is proportional to the ascorbic acid concentration.
The measured value is determined by direct color comparison with a 6-stage color chart provided. The method is specific for reducing substances such as ascorbic acid.
Advantages of the CALDUR® test set
Quick analysis in just 3 minutes
Ideal for regular checks in boiler systems and production processes – immediate results
Wide measuring range from 0.1 to 10 mg/l C₆H₈O₆
Covers the entire field of practical relevance for technical and food applications
100 provisions per set – economical in continuous use
Cost-efficient for daily checks in production facilities and quality assurance
Colorimetric use with color chart
Easy handling without additional devices – perfect for mobile applications
Specific ferrozine method
Proven measuring principle with high reliability
Robust, waterproof plastic housing with hinged lid
Safe transportation and protection of reagents – durable and reliable
Areas of application
Pond / lake
Groundwater / well water
Drinking / tap water
Aquaristics
Pool / Swimming pool
Industrial processing
Boiler water
Food preparation
Waste water treatment
Carrying out the measurement:
Fill water sample into test tube up to the 10 ml mark
Add 10 drops of reagent A and mix
Add 10 drops of reagent B and mix
Wait for 3 minutes reaction time (coloration develops)
Evaluation by color comparison with color chart
💡 Tip for best results
For best results, the water sample should be clear and free of suspended solids.
If the water is cloudy, pre-filtration with a filter paper (e.g. Whatman No. 1) is recommended.
The reaction time of 3 minutes should be observed, as the color intensity can develop over time.
⚠️ Important notes
Bring reagents to room temperature before use (20-25°C)
Observe a response time of 3 minutes for precise measurement results
Avoid direct sunlight during the measurement
Rinse test tubes thoroughly with distilled water after use
Other reducing substances can influence the measurement result
Measuring range
Measuring level
Description
0.1 mg/l
Very low concentration (light violet)
0.25 mg/l
Low concentration (violet)
0.5 mg/l
Elevated concentration (pink-violet)
1.0 mg/l
Medium concentration (pink-violet)
5.0 mg/l
High concentration (dark violet)
10.0 mg/l
Very high concentration (intense violet)
💡 Read intermediate values:
If the color is between two fields, you can form the mean value
(e.g. between 0.5 and 1.0 mg/l = approx. 0.7-0.8 mg/l).
Number of possible provisions
You can carry out 100 measurements with one CALDUR® ascorbic acid test kit.
This refers to the quantity of reagents contained.
Measuring accuracy and reproducibility
Readability: ± 1 color level Reproducibility: Very good if the application instructions are followed Interference: Other reducing substances (e.g. Sulfite, hydrazine) can also be measured and lead to increased measured values. Turbidity and coloration of the sample should be avoided (filter the sample if necessary).
What to do if measured values are out of range?
Measured value > 10 mg/l
Dilution
Procedure
Calculation of the measured value
1:1
5 ml sample + 5 ml distilled water
Measured value × 2
1:4
2 ml sample + 8 ml distilled water
Measured value × 5
1:9
1 ml sample + 9 ml distilled water
Measured value × 10
Measured value < 0.1 mg/l
The measured value is below the detection limit. This indicates
that the ascorbic acid concentration is very low.
2 reagent bottles (reagent A, B) with detailed labeling
1 test tube with 10 ml scale
1 color card with 6 measuring levels
Detailed operating instructions (DE/EN)
Safety data sheets for all reagents
Robust hinged lid box (103 x 91 x 36 mm)
Reagent details
Reagent
Volume
Shelf life
Notes
Reagent A
15 ml
48 months (48M)
Shake before use
Reagent B
15 ml
48 months (48M)
Shake before use
Shelf life: The shelf life starts from the date of manufacture (printed on the bottle).
After opening, the reagents should be used within 12 months.
Store the test kit in a dry, cool place (10-25°C) and away from direct sunlight.
We use cookies and analytics services (e.g. Google Analytics) to improve our website. Technically necessary services are always on. You can accept or decline optional services. More in the privacy policy