CALDUR® Chlorine dioxide – Colorimetric
Determination of chlorine dioxide in water using a color chart (0.05-0.5 mg/l)

Private customers can also find our range in our partner store Ampha-Analyse.
Reagent for CALDUR® Chlorine dioxide – Colorimetric:
See also:
CALDUR® Chlorine Dioxide Test Set – Colorimetric
What is chlorine dioxide measured for?
Chlorine dioxide (ClO₂) is a highly effective disinfectant that is used in drinking water treatment, the food industry and industrial water treatment. Compared to chlorine, chlorine dioxide has the advantage that it is also effective at higher pH values and does not form chloramines that impair the taste.
Precise monitoring of the chlorine dioxide concentration is crucial, as values that are too low mean insufficient disinfection, while concentrations that are too high pose health risks and can lead to undesirable by-products.
The limit value for drinking water in Germany is 0.2 mg/l (Drinking Water Ordinance). In practice, a residual value of 0.05 – 0.1 mg/l is often aimed for in order to ensure a continuous disinfection effect in the pipe network.
How does the test set work?
The CALDUR® Chlorine Dioxide Test Set – Colorimetric works according to the proven DPD method (diethyl-p-phenylenediamine). After adding two reagents to the water sample, a characteristic pink to violet coloration develops within about 1 minute, the intensity of which is proportional to the chlorine dioxide concentration.
The measured value is determined by comparison with a supplied color chart (colorimetric). A photometric measurement with the WINLAB Data Line photometer is also possible as an option.
Advantages of the CALDUR® test set
- Fastest analysis in just 1 minute
Ideal for on-site measurements – enables immediate process adjustments
- High sensitivity from 0.05 mg/l
Perfect for compliance with the Drinking Water Ordinance and residual value monitoring
- 140 determinations per set – economical in continuous use
Cost-efficient for regular inspections in waterworks and industry
- Can be used colorimetrically and optionally photometrically
Flexible for simple on-site tests or precise laboratory analyses with photometer
- Easy handling without special equipment
No additional technology required – ideal for quick tests on the go
- Robust, waterproof plastic housing with hinged lid
Safe transportation and protection of reagents – durable and reliable
Areas of application
Carrying out the measurement:
- Fill water sample into test tube up to the 10 ml mark
- Add 5 drops of reagent A (DPD) and swirl briefly
- Add 3 drops of reagent B (buffer) and mix
- After waiting 1 minute, compare the color with the color chart
- Evaluation by color comparison with color chart or photometric measurement
💡 Tip for best results
For precise measurements, the water sample should be clear. Carry out the color comparison in good lighting (daylight). Avoid direct sunlight, as this can affect color perception. The reaction time of 1 minute should be strictly adhered to, as the coloration can intensify over time.
⚠️ Important notes
- Bring reagents to room temperature before use
- Observe waiting time of 1 minute exactly for precise measurement results
- The simultaneous presence of free chlorine can lead to adulteration
- Rinse test tubes thoroughly with distilled water after use
Measuring range
| Measuring level | Description |
|---|---|
| 0.05 mg/l | Very low concentration (pale pink) |
| 0.1 mg/l | Low concentration (light pink) |
| 0.2 mg/l | Average concentration (pink) |
| 0.3 mg/l | Increased concentration (strong pink) |
| 0.4 mg/l | High concentration (pink-violet) |
| 0.5 mg/l | Very high concentration (violet) |
If the color lies between two fields, you can form the mean value
(e.g. between 0.1 and 0.2 mg/l = approx. 0.15 mg/l).
Number of possible determinations
You can carry out 140 measurements with a CALDUR® chlorine dioxide test kit.
This refers to the quantity of reagents contained.
Measuring accuracy and reproducibility
Readability: ± 1 color level
Reproducibility: Very good if the application instructions are followed
Interference: Free chlorine can influence the result. If chlorine and chlorine dioxide are present at the same time, the combined test set should be used. Turbidity of the sample can falsify the result (filter the sample if necessary).
What to do if measured values are out of range?
Measured value > 0.5 mg/l
| Dilution | Procedure | Calculation of the measured value |
|---|---|---|
| 1:1 | 5 ml sample + 5 ml distilled water | Measured value × 2 |
| 1:4 | 2 ml sample + 8 ml distilled water | Measured value × 5 |
| 1:9 | 1 ml sample + 9 ml distilled water | Measured value × 10 |
Measured value < 0.05 mg/l
Measured value is below the detection limit. This may mean that there is insufficient disinfection. Check the dosage of your disinfection system.
Specifications at a glance
Reagents (reagent A, B)
| Property | Value |
|---|---|
| Parameters | Chlorine dioxide (ClO₂) |
| Item number | 31-072270 |
| Method | Colorimetric (DPD method) |
| Measuring principle | Color comparison with 6-stage color chart |
| Measuring range | 0.05 to 0.5 mg/l |
| Color scale | 6 measuring levels (0.05 / 0.1 / 0.2 / 0.3 / 0.4 / 0.5 mg/l) |
| Analysis duration | 1 minute |
| Number of determinations | 140 |
| Number of reagents | 2 (reagent A, B) |
| Packaging | Hinged lid box |
| Packaging size | 103 x 91 x 36 mm |
| weight | approx. 120 g |
| Scope of delivery |
|---|
| 2 reagent bottles (reagent A, B) with detailed labeling |
| 1 test tube with 10 ml scale |
| 1 color card with 6 measuring levels |
| Detailed operating instructions (DE/EN) |
| Safety data sheets for all reagents |
| Robust hinged lid box (103 x 91 x 36 mm) |
Reagent details
| Reagent | Volume | Shelf life | Notes |
|---|---|---|---|
| Reagent A (DPD) | 30 ml | 24 months (24M) | Shake before use, store in a cool place |
| Reagent B (buffer) | 10 ml | 24 months (24M) | Shake before use |
Shelf life: The shelf life starts from the date of manufacture (printed on the bottle).
After opening, the reagents should be used within 12 months.
Store the test kit in a dry, cool place (10-25°C) and away from direct sunlight.
Additional information
| Packaging | Hinged lid box, Refill pack |
|---|---|
| Product category | Test kit |
Flyer
Operating instructions
Similar articles:
Related products
-
CALDUR® DEHA (diethylhydroxylamine) – Colorimetric
DEHA determination (diethylhydroxylamine) in boiler water by color chart (0.05-1.0 mg/l) -
CALDUR® pH 2-5 – Colorimetric
pH determination in the acidic range using a color chart (pH 2-5) -
CALDUR® Peroxide – Photometric
Peroxide determination in water using a photometer (1.0-100 mg/l H₂O₂)