Private customers can also find our range in our partner store Ampha-Analyse.
Reagent for CALDUR® Chlorine LR (free + combined) – Colorimetric:
See also:
CALDUR® Chlorine LR test set (free + combined) – Colorimetric
What is chlorine measured for?
Chlorine is the most commonly used disinfectant in the world for treating drinking water and swimming pool water. It reliably kills bacteria, viruses and other pathogens, thus ensuring hygienically safe water. In chlorination, a distinction is made between free chlorine and combined chlorine (chloramines), the sum of which is referred to as total chlorine.
Free chlorine is the active, disinfecting form and should be between 0.1 and 0.3 mg/l in drinking water. Combined chlorine is produced by the reaction of free chlorine with nitrogen-containing compounds (e.g. urea, ammonia) and has a significantly lower disinfecting effect. In swimming pools, combined chlorine is responsible for the typical “chlorine smell” and eye irritation.
Limit values according to the Drinking Water Ordinance:
– Free chlorine: max. 0.3 mg/l Cl₂
– Combined chlorine: max. 0.1 mg/l Cl₂
Regular measurement of both forms of chlorine is essential for effective disinfection while minimizing by-products. The CALDUR® Chlorine LR test set enables the separate determination of free and combined chlorine in the low concentration range.
How does the test set work?
The CALDUR® Chlorine LR test set is based on the proven DPD method (N,N-diethyl-p-phenylenediamine). DPD reacts with free chlorine to form a pink-violet dye, the intensity of which is proportional to the chlorine concentration.
Measurement of free chlorine: After the addition of reagent A, a pink coloration corresponding to the free chlorine content develops immediately.
Measurement of combined chlorine: After adding reagent C, the combined chlorine is also measured. The difference between total chlorine and free chlorine gives the combined chlorine content.
The measured value is determined by direct color comparison with a color chart provided. The DPD method is internationally recognized and complies with the DIN EN ISO 7393-2 standards and the recommendations of the WHO.
Advantages of the CALDUR® test set
Quick analysis in just 1 minute
Immediate results for free chlorine – ideal for daily routine checks
Separate determination of free and combined chlorine
Differentiated assessment of water quality and disinfection efficiency
Low measuring range 0.05 – 1.0 mg/l Cl₂
Perfect for drinking water monitoring and monitoring limit values
150 provisions per set – economical in continuous use
Cost-efficient for daily checks in waterworks and industry
DPD method according to international standards
Standard-compliant according to DIN EN ISO 7393-2 – globally recognized reference method
Robust, waterproof plastic housing with hinged lid
Safe transportation and protection of reagents – durable and reliable
Areas of application
Pond / lake
Groundwater / well water
Drinking / tap water
Aquaristics
Pool / Swimming pool
Industrial processing
Boiler water
Food preparation
Waste water treatment
Carrying out the measurement:
Measurement of free chlorine:
Fill water sample into test tube up to the 10 ml mark
Add 5 drops of reagent A and mix
Immediately perform color comparison with color chart (within 1 minute)
Measurement of total chlorine (free + bound):
After measuring the free chlorine: add 5 drops of reagent C
Wait 2 minutes
Perform color comparison again = total chlorine
Combined chlorine = total chlorine – free chlorine
Tip for best results
The measurement should be carried out immediately after sampling, as chlorine is volatile.
Avoid exposure to sunlight and do not heat the sample.
At high chlorine concentrations, the color may fade again after the maximum (bleaching) – in this case, dilute the sample.
Important notes
Measure the sample immediately after taking it – chlorine volatilizes quickly
Do not exceed the reaction time for free chlorine (max. 1 minute)
Avoid direct sunlight during the measurement
If the color fades: Dilute the sample and measure again
Rinse test tubes thoroughly with the sample before each measurement
Measuring range
Measuring level
Description
0.05 mg/l
Very low concentration (light pink)
0.1 mg/l
Low concentration (pink)
0.2 mg/l
Normal drinking water concentration (pink)
0.3 mg/l
Upper drinking water limit (pink-violet)
0.5 mg/l
Increased concentration (violet)
1.0 mg/l
High concentration (dark violet)
Read intermediate values:
If the color is between two fields, you can form the mean value
(e.g. between 0.2 and 0.3 mg/l = approx. 0.25 mg/l).
Number of possible provisions
You can carry out 150 measurements with a CALDUR® Chlorine LR test set.
This refers to the quantity of reagents contained.
Measuring accuracy and reproducibility
Readability: ± 1 color level Reproducibility: Very good if the application instructions are followed Interference: High concentrations of manganese or chromium can influence the result. Ozone and bromine also react with DPD.
What to do if measured values are out of range?
Measured value > 1.0 mg/l
Dilution
Procedure
Calculation of the measured value
1:1
5 ml sample + 5 ml chlorine-free water
Measured value × 2
1:4
2 ml sample + 8 ml chlorine-free water
Measured value × 5
Measured value < 0.05 mg/l
Measured value is below the detection limit. A minimum concentration of 0.1 mg/l free chlorine should be present in drinking water to ensure disinfection.
3 reagent bottles (reagent A, reagent B, reagent C) with detailed labeling
1 test tube with 10 ml scale
1 color card with 6 measuring levels
Detailed operating instructions (DE/EN)
Safety data sheets for all reagents
Robust hinged lid box (103 x 91 x 36 mm)
Reagent details
Reagent
Volume
Shelf life
Notes
Reagent A
30 ml
24 months (24M)
For free chlorine, shake before use
Reagent B
10 ml
24 months (24M)
Buffer, shake before use
Reagent C
10 ml
24 months (24M)
For total chlorine, shake before use
Shelf life: The shelf life starts from the date of manufacture (printed on the bottle).
After opening, the reagents should be used within 12 months.
Store the test kit in a dry, cool place (10-25°C) and away from direct sunlight.
Reagent for CALDUR® Chlorine LR (free + combined) – Colorimetric:
We use cookies
We use cookies and analytics services (e.g. Google Analytics) to improve our website. Technically necessary services are always on. You can accept or decline optional services. More in the privacy policy