{"id":31954,"date":"2026-03-12T11:30:53","date_gmt":"2026-03-12T10:30:53","guid":{"rendered":"https:\/\/rls-wacon.de\/produkt\/caldur-chlorine-dioxide-titrimetric\/"},"modified":"2026-03-12T11:30:53","modified_gmt":"2026-03-12T10:30:53","slug":"caldur-chlorine-dioxide-titrimetric","status":"publish","type":"product","link":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-chlorine-dioxide-titrimetric\/","title":{"rendered":"Caldur\u00ae Chlorine dioxide &#8211; Titrimetric"},"content":{"rendered":"<h2>CALDUR\u00ae Chlorine Dioxide Test Set &#8211; Titrimetric<\/h2>\n<h3>What is chlorine dioxide measured for?<\/h3>\n<p>Chlorine dioxide (ClO\u2082) is a highly effective disinfectant that is increasingly being used in drinking water treatment and industrial cooling water systems. Unlike chlorine, chlorine dioxide does not form halogenated by-products such as trihalomethanes (THM) and is also effective at higher pH values. <\/p>\n<p><strong>The recommended range for chlorine dioxide in drinking water is 0.05-0.4 mg\/l ClO\u2082<\/strong> (DVGW W 624). However, significantly higher concentrations can occur during the production and dosing of chlorine dioxide, which must be monitored precisely. <\/p>\n<p>This titrimetric test set is specially designed for monitoring higher concentrations. With a measured value of 2.5 mg\/l ClO\u2082 per drop, it is ideal for checking dosing systems, monitoring chlorine dioxide production and quality assurance in water treatment. <\/p>\n<h3>How does the test set work?<\/h3>\n<p>The CALDUR\u00ae chlorine dioxide test kit works according to the titrimetric principle with thiosulphate. The water sample is first mixed with two indicator solutions. The titration solution is then added drop by drop until a characteristic color change indicates the end point.  <\/p>\n<p><strong>Measuring principle:<\/strong> Chlorine dioxide oxidizes the added iodide to iodine, which is quantitatively determined by thiosulphate titration. Each drop of titration solution corresponds to 2.5 mg\/l ClO\u2082. <\/p>\n<p><strong>Calculation:<\/strong> The number of drops used multiplied by 2.5 directly results in the chlorine dioxide concentration in mg\/l.<\/p>\n<h3>Advantages of the CALDUR\u00ae test set<\/h3>\n<ul class=\"feature-list\">\n<li>Quantitative determination by titration\n<p style=\"text-indent: 30px; font-style: italic;\">Precise measurement results for system control and quality control<\/p>\n<\/li>\n<li>Measured value 2.5 mg\/l ClO\u2082 per drop\n<p style=\"text-indent: 30px; font-style: italic;\">Ideal for monitoring dosing systems and manufacturing processes<\/p>\n<\/li>\n<li>4 reagents for maximum accuracy\n<p style=\"text-indent: 30px; font-style: italic;\">2 Reagents and 1 titration solution ensure reliable results<\/p>\n<\/li>\n<li>Quick analysis in approx. 5 minutes\n<p style=\"text-indent: 30px; font-style: italic;\">Efficient on-site determination without laboratory equipment<\/p>\n<\/li>\n<li>10 to 25 mg\/l determinations per set\n<p style=\"text-indent: 30px; font-style: italic;\">Economical for regular operational control<\/p>\n<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>CALDUR\u00ae Chlorine Dioxide Test Set &#8211; Titrimetric What is chlorine dioxide measured for? Chlorine dioxide (ClO\u2082) is a highly effective disinfectant that is increasingly being used in drinking water treatment and industrial cooling water systems. Unlike chlorine, chlorine dioxide does not form halogenated by-products such as trihalomethanes (THM) and is also effective at higher pH [&hellip;]<\/p>\n","protected":false},"featured_media":31957,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[774,633,641],"product_tag":[],"class_list":{"0":"post-31954","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-chlorine-dioxide","7":"product_cat-testsets-caldur-en","8":"product_cat-titration-method","10":"first","11":"instock","12":"shipping-taxable","13":"purchasable","14":"product-type-variable"},"exclude_global_add_ons":[],"addons":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.6 (Yoast SEO v27.7) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>CALDUR\u00ae Chlorine Dioxide Test Set - Titrimetric<\/title>\n<meta name=\"description\" content=\"Precise chlorine dioxide measurement by titration with thiosulphate. 2.5 mg\/l per drop, 4 reagents. Ideal for dosing systems and water treatment!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/rls-wacon.de\/en\/produkt\/caldur-chlorine-dioxide-titrimetric\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Caldur\u00ae Chlorine dioxide - Titrimetric\" \/>\n<meta property=\"og:description\" content=\"Precise chlorine dioxide measurement by titration with thiosulphate. 2.5 mg\/l per drop, 4 reagents. Ideal for dosing systems and water treatment!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/rls-wacon.de\/en\/produkt\/caldur-chlorine-dioxide-titrimetric\/\" \/>\n<meta property=\"og:site_name\" content=\"RLS Wacon analytics\" \/>\n<meta property=\"og:image\" content=\"https:\/\/rls-wacon.de\/wp-content\/uploads\/2026\/03\/31-07227020-20Testset20Chlordioxid.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2067\" \/>\n\t<meta property=\"og:image:height\" content=\"1378\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Availability\" \/>\n\t<meta name=\"twitter:data1\" content=\"In stock\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-chlorine-dioxide-titrimetric\\\/\",\"url\":\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-chlorine-dioxide-titrimetric\\\/\",\"name\":\"CALDUR\u00ae Chlorine Dioxide Test Set - Titrimetric\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-chlorine-dioxide-titrimetric\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-chlorine-dioxide-titrimetric\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/rls-wacon.de\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/31-07227020-20Testset20Chlordioxid.jpg\",\"datePublished\":\"2026-03-12T10:30:53+00:00\",\"description\":\"Precise chlorine dioxide measurement by titration with thiosulphate. 2.5 mg\\\/l per drop, 4 reagents. Ideal for dosing systems and water treatment!\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-chlorine-dioxide-titrimetric\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-chlorine-dioxide-titrimetric\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-chlorine-dioxide-titrimetric\\\/#primaryimage\",\"url\":\"https:\\\/\\\/rls-wacon.de\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/31-07227020-20Testset20Chlordioxid.jpg\",\"contentUrl\":\"https:\\\/\\\/rls-wacon.de\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/31-07227020-20Testset20Chlordioxid.jpg\",\"width\":2067,\"height\":1378},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-chlorine-dioxide-titrimetric\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/rls-wacon.de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/rls-wacon.de\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Caldur\u00ae Chlorine dioxide &#8211; Titrimetric\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/#website\",\"url\":\"https:\\\/\\\/rls-wacon.de\\\/\",\"name\":\"RLS Wacon analytics GmbH\",\"description\":\"Experts for water monitoring\",\"publisher\":{\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/rls-wacon.de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/#organization\",\"name\":\"RLS Wacon analytics GmbH\",\"url\":\"https:\\\/\\\/rls-wacon.de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/rls-wacon.de\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/RLSWacon-analytics-Logo-BR-RZ-9_17-768x1591.png\",\"contentUrl\":\"https:\\\/\\\/rls-wacon.de\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/RLSWacon-analytics-Logo-BR-RZ-9_17-768x1591.png\",\"width\":768,\"height\":159,\"caption\":\"RLS Wacon analytics GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"CALDUR\u00ae Chlorine Dioxide Test Set - Titrimetric","description":"Precise chlorine dioxide measurement by titration with thiosulphate. 2.5 mg\/l per drop, 4 reagents. Ideal for dosing systems and water treatment!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-chlorine-dioxide-titrimetric\/","og_locale":"en_US","og_type":"article","og_title":"Caldur\u00ae Chlorine dioxide - Titrimetric","og_description":"Precise chlorine dioxide measurement by titration with thiosulphate. 2.5 mg\/l per drop, 4 reagents. Ideal for dosing systems and water treatment!","og_url":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-chlorine-dioxide-titrimetric\/","og_site_name":"RLS Wacon analytics","og_image":[{"width":2067,"height":1378,"url":"https:\/\/rls-wacon.de\/wp-content\/uploads\/2026\/03\/31-07227020-20Testset20Chlordioxid.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Availability":"In stock"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-chlorine-dioxide-titrimetric\/","url":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-chlorine-dioxide-titrimetric\/","name":"CALDUR\u00ae Chlorine Dioxide Test Set - Titrimetric","isPartOf":{"@id":"https:\/\/rls-wacon.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-chlorine-dioxide-titrimetric\/#primaryimage"},"image":{"@id":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-chlorine-dioxide-titrimetric\/#primaryimage"},"thumbnailUrl":"https:\/\/rls-wacon.de\/wp-content\/uploads\/2026\/03\/31-07227020-20Testset20Chlordioxid.jpg","datePublished":"2026-03-12T10:30:53+00:00","description":"Precise chlorine dioxide measurement by titration with thiosulphate. 2.5 mg\/l per drop, 4 reagents. Ideal for dosing systems and water treatment!","breadcrumb":{"@id":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-chlorine-dioxide-titrimetric\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/rls-wacon.de\/en\/produkt\/caldur-chlorine-dioxide-titrimetric\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-chlorine-dioxide-titrimetric\/#primaryimage","url":"https:\/\/rls-wacon.de\/wp-content\/uploads\/2026\/03\/31-07227020-20Testset20Chlordioxid.jpg","contentUrl":"https:\/\/rls-wacon.de\/wp-content\/uploads\/2026\/03\/31-07227020-20Testset20Chlordioxid.jpg","width":2067,"height":1378},{"@type":"BreadcrumbList","@id":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-chlorine-dioxide-titrimetric\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/rls-wacon.de\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/rls-wacon.de\/shop\/"},{"@type":"ListItem","position":3,"name":"Caldur\u00ae Chlorine dioxide &#8211; Titrimetric"}]},{"@type":"WebSite","@id":"https:\/\/rls-wacon.de\/#website","url":"https:\/\/rls-wacon.de\/","name":"RLS Wacon analytics GmbH","description":"Experts for water monitoring","publisher":{"@id":"https:\/\/rls-wacon.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/rls-wacon.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/rls-wacon.de\/#organization","name":"RLS Wacon analytics GmbH","url":"https:\/\/rls-wacon.de\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/rls-wacon.de\/#\/schema\/logo\/image\/","url":"https:\/\/rls-wacon.de\/wp-content\/uploads\/2022\/10\/RLSWacon-analytics-Logo-BR-RZ-9_17-768x1591.png","contentUrl":"https:\/\/rls-wacon.de\/wp-content\/uploads\/2022\/10\/RLSWacon-analytics-Logo-BR-RZ-9_17-768x1591.png","width":768,"height":159,"caption":"RLS Wacon analytics GmbH"},"image":{"@id":"https:\/\/rls-wacon.de\/#\/schema\/logo\/image\/"}}]},"og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/product\/31954","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/product\/31954\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/media\/31957"}],"wp:attachment":[{"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/media?parent=31954"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/product_brand?post=31954"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/product_cat?post=31954"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/product_tag?post=31954"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}