{"id":32455,"date":"2026-03-12T11:34:40","date_gmt":"2026-03-12T10:34:40","guid":{"rendered":"https:\/\/rls-wacon.de\/produkt\/caldur-phosphate-hr-colorimetric\/"},"modified":"2026-03-12T11:34:40","modified_gmt":"2026-03-12T10:34:40","slug":"caldur-phosphate-hr-colorimetric","status":"publish","type":"product","link":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-phosphate-hr-colorimetric\/","title":{"rendered":"Caldur\u00ae Phosphate HR &#8211; Colorimetric"},"content":{"rendered":"<h2>CALDUR\u00ae Phosphate HR Test Set &#8211; Colorimetric<\/h2>\n<h3>Why is phosphate measured in the high range?<\/h3>\n<p>In many industrial and municipal applications, phosphate concentrations occur that far exceed the range of conventional test sets. <strong>Wastewater treatment plants, cooling water circuits and dosing systems<\/strong> require reliable control even in the range of 2.5 to 100 mg\/l PO\u2084\u00b3-. <\/p>\n<p>Phosphate is dosed as a corrosion inhibitor in cooling water systems. Typical target concentrations are 5-20 mg\/l. Underdosing leads to corrosion, overdosing to unnecessary costs and deposits.  <\/p>\n<p>In sewage treatment plants, the phosphate concentration in the inlet is often 5-15 mg\/l. Monitoring the effluent ensures that the legal limits are adhered to. <\/p>\n<h3>How does the test set work?<\/h3>\n<p>The CALDUR\u00ae Phosphate HR test set is based on the molybdate method. Phosphate reacts with the molybdate reagent to form a colored complex. The color intensity is proportional to the phosphate concentration.  <\/p>\n<p>The measured value is determined by direct color comparison with a 6-stage color chart supplied.<\/p>\n<h3>Advantages of the CALDUR\u00ae test set<\/h3>\n<ul class=\"feature-list\">\n<li>Measuring range 2.5 &#8211; 100 mg\/l PO\u2084\u00b3-\n<p style=\"text-indent: 30px; font-style: italic;\">Ideal for industrial applications and wastewater treatment plants<\/p>\n<\/li>\n<li>100 provisions per set\n<p style=\"text-indent: 30px; font-style: italic;\">Economical for regular checks<\/p>\n<\/li>\n<li>Quick analysis in just 1 minute\n<p style=\"text-indent: 30px; font-style: italic;\">Immediate results without long waiting times<\/p>\n<\/li>\n<li>Easy handling with only 1 reagent\n<p style=\"text-indent: 30px; font-style: italic;\">No measuring devices required<\/p>\n<\/li>\n<li>Robust plastic housing with hinged lid\n<p style=\"text-indent: 30px; font-style: italic;\">Safe transportation and protection of reagents<\/p>\n<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>CALDUR\u00ae Phosphate HR Test Set &#8211; Colorimetric Why is phosphate measured in the high range? In many industrial and municipal applications, phosphate concentrations occur that far exceed the range of conventional test sets. Wastewater treatment plants, cooling water circuits and dosing systems require reliable control even in the range of 2.5 to 100 mg\/l PO\u2084\u00b3-. [&hellip;]<\/p>\n","protected":false},"featured_media":32459,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[637,750,633],"product_tag":[],"class_list":{"0":"post-32455","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-colorimetric-method","7":"product_cat-phosphate","8":"product_cat-testsets-caldur-en","10":"first","11":"instock","12":"shipping-taxable","13":"purchasable","14":"product-type-variable"},"exclude_global_add_ons":[],"addons":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.6 (Yoast SEO v27.7) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>CALDUR\u00ae Phosphate HR Test Set - Colorimetric<\/title>\n<meta name=\"description\" content=\"Measure phosphate in the high range with CALDUR\u00ae HR test set. 2.5-100 mg\/l PO\u2084\u00b3-, 100 determinations. For industry and sewage treatment plants!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/rls-wacon.de\/en\/produkt\/caldur-phosphate-hr-colorimetric\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Caldur\u00ae Phosphate HR - Colorimetric\" \/>\n<meta property=\"og:description\" content=\"Measure phosphate in the high range with CALDUR\u00ae HR test set. 2.5-100 mg\/l PO\u2084\u00b3-, 100 determinations. For industry and sewage treatment plants!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/rls-wacon.de\/en\/produkt\/caldur-phosphate-hr-colorimetric\/\" \/>\n<meta property=\"og:site_name\" content=\"RLS Wacon analytics\" \/>\n<meta property=\"og:image\" content=\"https:\/\/rls-wacon.de\/wp-content\/uploads\/2026\/03\/31-07241520-20Testset20Phosphat20HR.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2067\" \/>\n\t<meta property=\"og:image:height\" content=\"1378\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Availability\" \/>\n\t<meta name=\"twitter:data1\" content=\"In stock\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-phosphate-hr-colorimetric\\\/\",\"url\":\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-phosphate-hr-colorimetric\\\/\",\"name\":\"CALDUR\u00ae Phosphate HR Test Set - Colorimetric\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-phosphate-hr-colorimetric\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-phosphate-hr-colorimetric\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/rls-wacon.de\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/31-07241520-20Testset20Phosphat20HR.jpg\",\"datePublished\":\"2026-03-12T10:34:40+00:00\",\"description\":\"Measure phosphate in the high range with CALDUR\u00ae HR test set. 2.5-100 mg\\\/l PO\u2084\u00b3-, 100 determinations. For industry and sewage treatment plants!\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-phosphate-hr-colorimetric\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-phosphate-hr-colorimetric\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-phosphate-hr-colorimetric\\\/#primaryimage\",\"url\":\"https:\\\/\\\/rls-wacon.de\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/31-07241520-20Testset20Phosphat20HR.jpg\",\"contentUrl\":\"https:\\\/\\\/rls-wacon.de\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/31-07241520-20Testset20Phosphat20HR.jpg\",\"width\":2067,\"height\":1378},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/en\\\/produkt\\\/caldur-phosphate-hr-colorimetric\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/rls-wacon.de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/rls-wacon.de\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Caldur\u00ae Phosphate HR &#8211; Colorimetric\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/#website\",\"url\":\"https:\\\/\\\/rls-wacon.de\\\/\",\"name\":\"RLS Wacon analytics GmbH\",\"description\":\"Experts for water monitoring\",\"publisher\":{\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/rls-wacon.de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/#organization\",\"name\":\"RLS Wacon analytics GmbH\",\"url\":\"https:\\\/\\\/rls-wacon.de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/rls-wacon.de\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/RLSWacon-analytics-Logo-BR-RZ-9_17-768x1591.png\",\"contentUrl\":\"https:\\\/\\\/rls-wacon.de\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/RLSWacon-analytics-Logo-BR-RZ-9_17-768x1591.png\",\"width\":768,\"height\":159,\"caption\":\"RLS Wacon analytics GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/rls-wacon.de\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"CALDUR\u00ae Phosphate HR Test Set - Colorimetric","description":"Measure phosphate in the high range with CALDUR\u00ae HR test set. 2.5-100 mg\/l PO\u2084\u00b3-, 100 determinations. For industry and sewage treatment plants!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-phosphate-hr-colorimetric\/","og_locale":"en_US","og_type":"article","og_title":"Caldur\u00ae Phosphate HR - Colorimetric","og_description":"Measure phosphate in the high range with CALDUR\u00ae HR test set. 2.5-100 mg\/l PO\u2084\u00b3-, 100 determinations. For industry and sewage treatment plants!","og_url":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-phosphate-hr-colorimetric\/","og_site_name":"RLS Wacon analytics","og_image":[{"width":2067,"height":1378,"url":"https:\/\/rls-wacon.de\/wp-content\/uploads\/2026\/03\/31-07241520-20Testset20Phosphat20HR.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Availability":"In stock"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-phosphate-hr-colorimetric\/","url":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-phosphate-hr-colorimetric\/","name":"CALDUR\u00ae Phosphate HR Test Set - Colorimetric","isPartOf":{"@id":"https:\/\/rls-wacon.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-phosphate-hr-colorimetric\/#primaryimage"},"image":{"@id":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-phosphate-hr-colorimetric\/#primaryimage"},"thumbnailUrl":"https:\/\/rls-wacon.de\/wp-content\/uploads\/2026\/03\/31-07241520-20Testset20Phosphat20HR.jpg","datePublished":"2026-03-12T10:34:40+00:00","description":"Measure phosphate in the high range with CALDUR\u00ae HR test set. 2.5-100 mg\/l PO\u2084\u00b3-, 100 determinations. For industry and sewage treatment plants!","breadcrumb":{"@id":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-phosphate-hr-colorimetric\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/rls-wacon.de\/en\/produkt\/caldur-phosphate-hr-colorimetric\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-phosphate-hr-colorimetric\/#primaryimage","url":"https:\/\/rls-wacon.de\/wp-content\/uploads\/2026\/03\/31-07241520-20Testset20Phosphat20HR.jpg","contentUrl":"https:\/\/rls-wacon.de\/wp-content\/uploads\/2026\/03\/31-07241520-20Testset20Phosphat20HR.jpg","width":2067,"height":1378},{"@type":"BreadcrumbList","@id":"https:\/\/rls-wacon.de\/en\/produkt\/caldur-phosphate-hr-colorimetric\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/rls-wacon.de\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/rls-wacon.de\/shop\/"},{"@type":"ListItem","position":3,"name":"Caldur\u00ae Phosphate HR &#8211; Colorimetric"}]},{"@type":"WebSite","@id":"https:\/\/rls-wacon.de\/#website","url":"https:\/\/rls-wacon.de\/","name":"RLS Wacon analytics GmbH","description":"Experts for water monitoring","publisher":{"@id":"https:\/\/rls-wacon.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/rls-wacon.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/rls-wacon.de\/#organization","name":"RLS Wacon analytics GmbH","url":"https:\/\/rls-wacon.de\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/rls-wacon.de\/#\/schema\/logo\/image\/","url":"https:\/\/rls-wacon.de\/wp-content\/uploads\/2022\/10\/RLSWacon-analytics-Logo-BR-RZ-9_17-768x1591.png","contentUrl":"https:\/\/rls-wacon.de\/wp-content\/uploads\/2022\/10\/RLSWacon-analytics-Logo-BR-RZ-9_17-768x1591.png","width":768,"height":159,"caption":"RLS Wacon analytics GmbH"},"image":{"@id":"https:\/\/rls-wacon.de\/#\/schema\/logo\/image\/"}}]},"og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/product\/32455","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/product\/32455\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/media\/32459"}],"wp:attachment":[{"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/media?parent=32455"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/product_brand?post=32455"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/product_cat?post=32455"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/rls-wacon.de\/en\/wp-json\/wp\/v2\/product_tag?post=32455"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}