CALDUR® Ascorbic acid – Colorimetric
Ascorbic acid determination in water using a color chart (0.1-10 mg/l C₆H₈O₆)

Private customers can also find our range in our partner store Ampha-Analyse.
Reagent for CALDUR® Ascorbic acid – Colorimetric:
See also:
CALDUR® Ascorbic acid test kit – Colorimetric
What is ascorbic acid measured for?
Ascorbic acid (vitamin C, C₆H₈O₆) is used in water treatment as an oxygen binding and reducing agent. In the food industry, ascorbic acid is used as an antioxidant and preservative to prevent the oxidation of food and extend its shelf life.
In steam boilers and closed cooling systems, ascorbic acid is used in a similar way to Sulfite to bind dissolved oxygen in order to prevent corrosion. Ascorbic acid reacts with oxygen to form dehydroascorbic acid and thus protects pipes and system components from oxygen corrosion.
The optimum ascorbic acid concentration in technical applications is typically 10-50 mg/l C₆H₈O₆. In the food industry, the concentrations vary greatly depending on the application and must be controlled on a product-specific basis.
How does the test set work?
The CALDUR® Ascorbic Acid Test Set – Colorimetric is based on the ferrozine method. Ascorbic acid reduces iron(III) to iron(II), which then forms a violet color complex with ferrozine. After adding two reagents to the water sample, a characteristic violet color develops within 3 minutes, the intensity of which is proportional to the ascorbic acid concentration.
The measured value is determined by direct color comparison with a 6-stage color chart provided. The method is specific for reducing substances such as ascorbic acid.
Advantages of the CALDUR® test set
- Quick analysis in just 3 minutes
Ideal for regular checks in boiler systems and production processes – immediate results
- Wide measuring range from 0.1 to 10 mg/l C₆H₈O₆
Covers the entire field of practical relevance for technical and food applications
- 100 determinations per set – economical in continuous use
Cost-efficient for daily checks in production facilities and quality assurance
- Colorimetric use with color chart
Easy handling without additional devices – perfect for mobile applications
- Specific ferrozine method
Proven measuring principle with high reliability
- Robust, waterproof plastic housing with hinged lid
Safe transportation and protection of reagents – durable and reliable
Areas of application
⚠️ Hazard information (from the label)

Ascorbic acid reagent A – Danger
H290 May be corrosive to metals. H314 Causes severe skin burns and eye damage.
Full information on all components: see the safety data sheet (SDS).
Carrying out the measurement:
- Fill water sample into test tube up to the 10 ml mark
- Add 10 drops of reagent A and mix
- Add 10 drops of reagent B and mix
- Wait for 3 minutes reaction time (coloration develops)
- Evaluation by color comparison with color chart
💡 Tip for best results
For best results, the water sample should be clear and free of suspended solids.
If the water is cloudy, pre-filtration with a filter paper (e.g. Whatman No. 1) is recommended.
The reaction time of 3 minutes should be observed, as the color intensity can develop over time.
⚠️ Important notes
- Bring reagents to room temperature before use (20-25°C)
- Observe a reaction time of 3 minutes for precise measurement results
- Avoid direct sunlight during the measurement
- Rinse test tubes thoroughly with distilled water after use
- Other reducing substances can influence the measurement result
Measuring range
| Measuring level | Description |
|---|---|
| 0.1 mg/l | Very low concentration (light violet) |
| 0.25 mg/l | Low concentration (violet) |
| 0.5 mg/l | Elevated concentration (pink-violet) |
| 1.0 mg/l | Medium concentration (pink-violet) |
| 5.0 mg/l | High concentration (dark violet) |
| 10.0 mg/l | Very high concentration (intense violet) |
If the color is between two fields, you can form the mean value
(e.g. between 0.5 and 1.0 mg/l = approx. 0.7-0.8 mg/l).
Number of possible determinations
You can carry out 100 measurements with one CALDUR® ascorbic acid test kit.
This refers to the quantity of reagents contained.
Measuring accuracy and reproducibility
Readability: ± 1 color level
Reproducibility: Very good if the application instructions are followed
Interference: Other reducing substances (e.g. Sulfite, hydrazine) can also be measured and lead to increased measured values. Turbidity and coloration of the sample should be avoided (filter the sample if necessary).
What to do if measured values are out of range?
Measured value > 10 mg/l
| Dilution | Procedure | Calculation of the measured value |
|---|---|---|
| 1:1 | 5 ml sample + 5 ml distilled water | Measured value × 2 |
| 1:4 | 2 ml sample + 8 ml distilled water | Measured value × 5 |
| 1:9 | 1 ml sample + 9 ml distilled water | Measured value × 10 |
Measured value < 0.1 mg/l
The measured value is below the detection limit. This indicates
that the ascorbic acid concentration is very low.
Specifications at a glance
Reagents (reagent A, B)
| Property | Value |
|---|---|
| Parameters | Ascorbic acid (C₆H₈O₆) |
| Item number | 31-072220 |
| Method | Colorimetric (ferrozine) |
| Measuring principle | Color comparison with 6-stage color chart |
| Measuring range | 0.1 to 10 mg/l C₆H₈O₆ |
| Color scale | 6 measuring levels (0.1 / 0.25 / 0.5 / 1.0 / 5.0 / 10.0 mg/l) |
| Analysis time | 3 minutes |
| Number of determinations | 100 |
| Packaging | Hinged lid box |
| Packaging size | 103 x 91 x 36 mm |
| weight | approx. 160 g |
| Scope of delivery |
|---|
| 2 reagent bottles (reagent A, B) with detailed labeling |
| 1 test tube with 10 ml scale |
| 1 color card with 6 measuring levels |
| Detailed operating instructions (DE/EN) |
| Safety data sheets for all reagents |
| Robust hinged lid box (103 x 91 x 36 mm) |
Reagent details
| Reagent | Volume | Shelf life | Notes |
|---|---|---|---|
| Reagent A | 15 ml | 48 months (48M) | Shake before use |
| Reagent B | 15 ml | 48 months (48M) | Shake before use |
Shelf life: The shelf life starts from the date of manufacture (printed on the bottle).
After opening, the reagents should be used within 12 months.
Store the test kit in a dry, cool place (10-25°C) and away from direct sunlight.
Additional information
| Packaging | Hinged lid box, Refill pack |
|---|---|
| Product category | Test kit |
Flyer
Operating instructions
Similar articles:
Related products
-
CALDUR® pH 5-8 – Colorimetric
pH determination in the neutral range using a color chart (pH 5-8) -
CALDUR® Iron LR – Photometric
Determination of iron in water using a photometer (0.2-2.0 mg/l Fe) -
CALDUR® Phosphate LR – Photometric
Phosphate determination in the water using a photometer (0.4-5 mg/l PO₄³-)