Which device is right for my application?
This depends primarily on whether an exact measured value or a threshold monitoring is required:
- LIMES – compact limit value monitoring of total hardness, ideal after a water softener
- SYCON 2602 – colorimetric limit value monitoring with graphic display, relay outputs and SD card
- SYCON 2702 – titration analyser with exact measured value, 4-20 mA output and Modbus interface
- SYCON 2802 – premium titration analyser with two limit values, four relays and all interfaces
A detailed comparison of all models is available on the SYCON comparison page.
Which reagent do I need?
The right reagent depends on the parameter to be monitored (e.g. total hardness, carbonate hardness) and the measuring range. For hardness, there are several H25 reagents, each for a different range. Choose the reagent so that your expected value is in the middle of its measuring range.
You find all reagents with their measuring ranges and matching devices on the reagent overview page.
How does the measurement work?
All SYCON devices work fully automatically. The sample water flows into the measuring chamber, and the device adds the reagent automatically. An optical sensor then checks the colour change.
- SYCON 2602 & LIMES – use a colour test with a limit value. The device adds the reagent and measures the colour. It shows if the water is above or below the limit value.
- SYCON 2702 & 2802 – use colorimetric titration. The device adds the reagent drop by drop. From the colour change, it calculates the exact value.
Which parameters can be monitored besides water hardness?
In addition to total hardness and carbonate hardness, the SYCON series covers further important parameters in water analytics:
- Iron (Fe) – with the SYCON Fe
Elevated iron levels cause discoloration in drinking water and deposits in pipelines – particularly relevant when treating well water - Silicate (SiO2) – with the SYCON SiO2
Even low silicate concentrations can lead to deposits on turbine blades – continuous monitoring protects costly power plant components - p-value / alkalinity – with the SYCON P
The p-value is a key parameter for corrosion protection in boiler water and cooling water circuits
Each device is specialized for its parameter and operates fully automatically using the same proven measurement principle.
Where are the analysers typically used?
SYCON and LIMES devices are used in many areas of water treatment and monitoring:
| Device | Typical application areas |
|---|---|
| LIMES | Water softeners, soft water monitoring, building services Prevent limescale deposits in pipelines and heat exchangers early on – an exhausted softening system often goes unnoticed without monitoring |
| SYCON 2602 | Water softeners, industrial processes, drinking water treatment Reliable limit value monitoring that starts the regeneration automatically – protects systems and saves regeneration chemicals |
| SYCON 2702 / 2802 | Waterworks, industrial process water treatment, boiler feed water, district heating networks Precise measured values enable accurate control and documentation of water quality – essential wherever limit values must be verifiably maintained |
| SYCON BoB | Steam boiler systems, monitoring of boiler feed water and condensate TÜV-certified according to WÜV 100 – meets the requirement for 72-hour operational monitoring of steam boiler systems |
| SYCON Fe | Drinking water treatment, well water monitoring, corrosion control Elevated iron levels lead to discoloration and deposits – continuous monitoring detects problems before they become visible to the consumer |
| SYCON SiO2 | Power plants, mixed bed filter monitoring, ultrapure water treatment Even low silicate concentrations can cause turbine deposits – early detection protects costly plant components |
| SYCON P | Boiler water monitoring, cooling water circuits, industrial processes The p-value (alkalinity) is crucial for corrosion protection – a value that is too low or too high attacks pipelines and heat exchangers |
What are the requirements for connection?
The following conditions should be met for trouble-free operation:
- Water pressure: min. 0.5 bar, max. 5 bar (recommended 1–2 bar)
- Water temperature: 5–40 °C – a sample cooler should be used at higher temperatures
- Water quality: clear, free of solids and without gas bubbles
- Power supply: depending on device variant 24 V AC/DC or 100–240 V AC – please check the rating plate
- Drain hose: keep as short as possible and lead freely into a funnel or drain
You find the installation steps in the operating instructions of your device.
How often is maintenance required and what is needed?
All SYCON and LIMES devices operate largely maintenance-free. Recommended intervals:
| Interval | Action |
|---|---|
| Every 6 months | Cleaning the measuring chamber (using the SYCON Clean cleaning kit incl. FIT 3000) |
| Every 24 months or after 30,000 analyses | Installation of the maintenance kit (peristaltic pump cassette, seals, stirrer) |
Clean more often if the water is hot or contains organic dirt. Cleaning the measuring chamber takes about 20 minutes.
Maintenance kits and cleaning kits are available as accessories.
What do the error messages E11, E12, E13 and E14 mean?
| Code | Meaning | First step |
|---|---|---|
| E11 | Indicator | Check reagent level and tube connections |
| E12 | Water flow | Check water inlet and pressure |
| E13 | Sensor | Check measuring chamber for contamination |
| E14 | Optics | Check the measuring chamber for air bubbles or cloudy water |
You find a checklist for each error message in the operating instructions.
The device does not perform a measurement – what can be checked?
The following points can be checked first:
- Is the water inlet open and sufficient pressure available?
- Is the reagent bottle inserted and are the tube connections OK?
- Is an SD card inserted?
- Is the device in automatic mode?
How is a software update performed?
The current software file is copied to the SD card. When switching on the device, hold down the OK button – the device detects the new version and performs the update automatically.
How is measurement data stored and retrieved?
All analysis results are automatically logged on the SD card in CSV format. The card can be removed and read on a PC. More than 100,000 analyses can be stored.
Recommendation: Use SD cards from the Transcend brand.
Is integration with PLC or SCADA systems possible?
Yes. SYCON devices offer two ways to integrate into higher-level systems:
- Analog output 4–20 mA – for direct measured value transmission
- RS-485 / Modbus RTU – for digital communication with PLC and SCADA systems
You find the settings in the operating instructions and in the separate Modbus manual.
What is CALDUR® and which parameters can be determined?
CALDUR® is our brand for manual water test kits. All test kits are easy to use and give precise results.
The range includes test kits for the following parameters, among others:
- Total hardness & carbonate hardness
- Residual hardness
- Chlorine (free & combined)
- Iron
- pH value
- Phosphate, nitrate, nitrite
- Copper, manganese, aluminium
- Silicate, sulphite, chloride
- and many more
The complete range can be found in the online shop.
What is the difference between colorimetric, photometric and titrimetric?
| Method | How it works | Accessories required? |
|---|---|---|
| Colorimetric | Colour comparison with the colour chart in the kit – quick test on site | No |
| Photometric | Evaluation with a photometer – higher accuracy through digital measurement | Yes (e.g. WINLAB Data Line) |
| Titrimetric | Classic drop titration – proven method for parameters such as hardness and alkalinity | No |
Which test kit is right for my application?
The choice depends on the parameter to be determined and the preferred method. A simple guide:
- Quick on-site check without instruments → colorimetric test kit
- Higher accuracy with digital results → photometric test kit
- Precise test of hardness or alkalinity → titrimetric test kit or CALDUR® Scientific
What is CALDUR® Scientific and what advantages does it offer?
CALDUR® Scientific uses syringe titration – an improved form of classic drop titration. Instead of counting drops, you add the reagent with a syringe with a scale. The measured value can be read directly and continuously from the scale.
Advantages at a glance:
- Continuous reading – no counting of individual drops
- Fast analysis in about 1 minute
- Up to 200 tests per kit – low cost for regular use
- Ideal for monitoring water softening and treatment systems
Available for: residual hardness, total hardness, carbonate hardness and p-value.
What accessories are needed for the test kits?
- Colorimetric tests: no additional accessories required – everything needed is included in the kit
- Photometric tests: a compatible photometer, e.g. the WINLAB Data Line
- Titrimetric tests & Scientific: everything needed is included in the kit
Where can I find operating instructions and data sheets?
You can download all operating instructions, data sheets and product flyers free of charge, in several languages, on the downloads page.
How can a repair be requested?
A repair can be requested directly via the online repair form. After receiving the request, technical support will respond with the next steps.
Who can be contacted for technical questions?
Technical support is available for all questions regarding water analytics:
- E-mail: support@rls-wacon.de
- Phone: +49 (0)5121 28126-24
- Availability: Mon–Thu 07:00–16:30, Fri 07:00–13:00 (CET)