SYCON in comparison

Find the right analyzer for your application

Features

  • Functional principle:
  • Limit value:
  • Parameters:
  • Units:
  • Reagent consumption:
  • Measuring point/range:

    (see Reagent)

  • Fully automatic operation
  • BOB - Functionality1
  • Diagnostic program
  • Time-controlled analysis interval
  • Quantity-controlled analysis interval
  • Measured value log on SD card
  • Modbus RTU interface
  • Analog output (4 ... 20 mA)

  • Relay functions
  • Limit value 1
  • Limit value 2
  • Analysis active / cooling water
  • Operational readiness
  • BOB Warning

  • Input functions
  • Flow monitor
  • Interval Reset2
  • External analysis start
  • Analysis termination
  • Water meter
All analyzers
- BASIC -

SYCON 2602

  • Limit value device
    The analyzer determines whether a water hardness limit value has been reached (good/bad measurement).
    Limit value is determined by the Reagent used.
  • determined by Reagent
  • Total hardness, carbonate hardness
  • °dH, °f, °e, ppm, mmol/l, °Ж
  • <0.1 ml / analysis
    min. 5000 analyses / 500 ml
  • Reagent




Sycon 2602
- BUDGET -

SYCON 2702

  • Titration device
    The analyzer measures the water hardness within a specific measuring range and provides an accurate result.
    The measuring range is determined by the Reagent used.
  • an adjustable limit value
  • Total hardness, carbonate hardness
  • °dH, °f, °e, ppm, mmol/l, °Ж
  • <0.05 ml / analysis
    min. 10000 analyses / 500 ml
  • Reagent




Sycon 2702
- PREMIUM -

SYCON 2802

  • Titration device
    The analyzer measures the water hardness within a specific measuring range and provides an accurate result.
    The measuring range is determined by the Reagent used.
  • Two adjustable limit values
  • Total hardness, carbonate hardness
  • °dH, °f, °e, ppm, mmol/l, °Ж
  • <0.05 ml / analysis
    min. 10000 analyses / 500 ml
  • Reagent




Sycon 2802
BOB functionality1: The analyzer indicates whether there is a sufficient supply of Reagent for at least the next 72 hours.
Interval Reset2: Recommended for pendulum softening systems. A running analysis can be canceled via the input when switching to the other water softener. This ensures that the measurement result is always assigned to the correct system by the control unit.
Features:
  • Functional principle:
  • Limit value:
  • Parameters:
  • Units:
  • Reagent consumption:
  • Measuring point/range:

    (see Reagent)

  • Fully automatic operation
  • BOB - Functionality1
  • Diagnostic program
  • Time-controlled analysis interval
  • Quantity-controlled analysis interval
  • Measured value log on SD card
  • Modbus RTU interface
  • Analog output (4 ... 20 mA)

  • Relay functions
  • Limit value 1
  • Limit value 2
  • Analysis active / cooling water
  • Operational readiness
  • BOB Warning

  • Input functions
  • Flow monitor
  • Interval Reset2
  • External analysis start
  • Analysis termination
  • Water meter