pH and chlorine (free) determination in water using a color chart (pH 6.8-8.0 / Cl₂ 0.1-1.0 mg/l)

Private customers can also find our range in our partner store Ampha-Analyse.
Reagent for CALDUR® pH / chlorine (free) – Colorimetric:
See also:
CALDUR® pH / Chlorine (free) test set – Colorimetric
What are pH and free chlorine measured for?
pH value and free chlorine are the two most important parameters for monitoring swimming and bathing pool water. The pH value directly influences the disinfection effect of chlorine: The effectiveness of chlorine is highest at an optimum pH value (7.0-7.4).
This practical combination test set enables the simultaneous determination of both parameters and is therefore the ideal tool for daily swimming pool monitoring.
Standard values for swimming pool water: pH 7.0-7.4, free chlorine 0.3-0.6 mg/l (DIN 19643).
How does the test set work?
The combination test set contains two separate measuring systems:
pH measurement: After adding phenol red Reagent, the sample changes color from yellow (acidic) to orange to red (basic) depending on the pH value.
Chlorine measurement: After adding the DPD reagents (chlorine A + B), the sample turns pink to violet in proportion to the chlorine concentration.
Advantages of the CALDUR® test set
- Two parameters in one test set
Measure pH and free chlorine simultaneously – time-saving and practical
- Quick analysis in just 1 minute
Ideal for daily swimming pool checks
- 50 determinations per parameter
Economical for regular checks
- pH range 6.8 – 8.0
Optimized for the swimming pool area
- Chlorine range 0.1 – 1.0 mg/l
Covers the recommended range for swimming pool water
Areas of application
Carrying out the measurement:
pH measurement:
- Fill water sample into pH test tubes up to the 10 ml mark
- Add 5 drops of phenol red Reagent and mix
- Compare color with pH color chart
Chlorine measurement:
- Fill the water sample into chlorine test tubes up to the 10 ml mark
- Add 5 drops of chlorine A and mix
- Add 3 drops of chlorine B and mix
- Immediately compare color with chlorine color chart (within 1 minute)
Tip for best results
The measurement should be taken directly at the edge of the pool, as chlorine is more volatile than is often assumed. Measure at different points in the pool to obtain a representative picture. Ideal measurement times: in the morning before bathing and in the evening after closing.
Important notes
- Measure the sample immediately after taking it – chlorine volatilizes
- Read chlorine measurement within 1 minute
- Avoid direct sunlight during the measurement
- If the chlorine color fades: dilute the sample and measure again
- Thoroughly rinse the test tube with the sample before each measurement
- Always check pH and chlorine together – they influence each other
Measuring range pH
| Measuring level | Description |
|---|---|
| 6.8 | Slightly acidic (yellow-orange) |
| 7.2 | Optimal – lower range (orange) |
| 7.6 | Optimal – upper range (red-orange) |
| 8.0 | Slightly alkaline (red) |
Measuring range chlorine (free)
| Measuring level | Description |
|---|---|
| 0.1 mg/l | Low concentration (pale pink) |
| 0.5 mg/l | Average concentration (pink) |
| 1.0 mg/l | High concentration (strong pink) |
If the color lies between two fields, you can calculate the average value.
Number of possible determinations
With a CALDUR® test set pH / chlorine (free) you can carry out 50 measurements per parameter.
This refers to the quantity of reagents contained.
Measuring accuracy and reproducibility
Readability pH: ± 0.2 pH units
Chlorine readability: ± 1 color level
Reproducibility: Very good if the application instructions are followed
Interference Chlorine: Bromine and other oxidizing agents also react with DPD. At high concentrations, color fading may occur – in this case, dilute the sample.
What to do if measured values are out of range?
Chlorine > 1.0 mg/l
| Dilution | Execution | Calculation of the measured value |
|---|---|---|
| 1:1 | 5 ml sample + 5 ml chlorine-free water | Measured value × 2 |
pH outside 6.8-8.0
Use the appropriate CALDUR® pH test set (pH 2-5, pH 5-8 or pH 8-12) for the corresponding range.
Specifications at a glance
Reagents (3 reagents)
| Property | Value |
|---|---|
| Parameters | pH value + free chlorine (Cl₂) |
| Item number | 31-072290 |
| Method | Colorimetric (phenol red / DPD) |
| Measuring principle | Color comparison with color charts |
| Measuring range pH | 6.8 / 7.2 / 7.6 / 8.0 |
| Measuring range chlorine | 0.1 / 0.5 / 1.0 mg/l Cl₂ |
| Analysis duration | 1 minute |
| Number of determinations | 50 each (pH and chlorine) |
| Reagents pH | 1 (phenol red) |
| Reagents Chlorine | 2 (Chlorine A + B, DPD) |
| Packaging | Hinged lid box |
| Packaging size | 103 x 91 x 36 mm |
| weight | approx. 170 g |
| Scope of delivery |
|---|
| 3 reagent bottles (phenol red, chlorine A, chlorine B) with detailed labeling |
| 2 test tubes (1x pH, 1x chlorine) with 10 ml scale |
| 2 color cards (1x pH with 4 measuring levels, 1x chlorine with 3 measuring levels) |
| Detailed operating instructions (DE/EN) |
| Safety data sheets for all reagents |
| Robust hinged lid box (103 x 91 x 36 mm) |
Reagent details
| Reagent | Volume | Shelf life | Notes |
|---|---|---|---|
| Phenol red (pH Reagent) | 15 ml | 24 months (24M) | pH Reagent, shake before use |
| Chlorine A (DPD 1) | 15 ml | 24 months (24M) | DPD reagent, shake before use |
| Chlorine B (buffer) | 10 ml | 24 months (24M) | Buffer solution, shake before use |
Shelf life: The shelf life starts from the date of manufacture (printed on the bottle).
After opening, the reagents should be used within 12 months.
Store the test kit in a dry, cool place (10-25°C) and protected from direct sunlight.
Additional information
| Packaging | Hinged lid box, Refill pack |
|---|---|
| Product category | Test kit |
Flyer
Operating instructions
Similar articles:
Related products
-
CALDUR® Residual hardness RG 10 – Limit value
Residual hardness limit value determination in the water (limit value: 0.1 °dH) -
CALDUR® Iron LR – Photometric
Determination of iron in water using a photometer (0.2-2.0 mg/l Fe) -
CALDUR® Sulfide – Photometric
Determination of sulphide in water by photometer (0.05-1.0 mg/l S²-)