Our telephone system is currently out of service due to line work. You can reach us by e-mail at info@rls-wacon.de or by calling +49 (0)151/1054 1979 --- Our telephone system is currently out of service due to line work. You can reach us by e-mail at info@rls-wacon.de or by calling +49 (0)151/1054 1979 --- Our telephone system is currently out of service due to line work. You can reach us by e-mail at info@rls-wacon.de or by calling +49 (0)151/1054 1979 ---

Caldur® Sulfide – Photometric

Determination of sulphide in water by photometer (0.05-1.0 mg/l S²-)
Article number: 
N/A Categories , ,
Select the desired properties:
Quantity
Add to Quote
Request a quote

Private customers can also find our range in our partner store Ampha-Analyse.

Reagent for Caldur® Sulfide – Photometric:
See also:

CALDUR® Sulfide Test Set – Photometric

What is sulfide measured for?

Sulphide (S²-) is produced by the anaerobic decomposition of organic substances containing sulphur and can cause an unpleasant smell of rotten eggs as hydrogen sulphide (H₂S). Even low concentrations are corrosive and can damage pipelines and structures.

Sulphide is harmful to health in higher concentrations and can cause respiratory and eye irritation in people who work with contaminated water. Sulphide is undesirable in drinking water treatment and must be reliably detected.

In industrial water treatment, in sewage treatment plants and in groundwater samples, sulphide control is essential to prevent corrosion and ensure water quality.

How does the test set work?

The CALDUR® Sulfide Test Set – Photometric is based on the DPD method. After adding two reagents to the water sample, a characteristic coloration develops within 7 minutes, the concentration of which is precisely determined with the WINLAB Data Line photometer.

Advantages of the CALDUR® test set

  • Sensitive measuring range 0.05 – 1.0 mg/l S²-

    Detection of even low sulphide concentrations

  • 100 provisions per set

    Economical for regular checks

  • High precision due to photometric evaluation

    Objective, reproducible measurement results with the WINLAB Data Line

  • Proven DPD method

    Reliable results even with stained samples

Areas of application

Pond / lake
Groundwater / well water
Drinking / tap water
Aquaristics
Pool / Swimming pool
Industrial processing
Boiler water
Food preparation
Waste water treatment

Carrying out the measurement:

  1. Fill the round cuvette with sample up to the 10 ml mark
  2. Add 5 drops of reagent A and mix
  3. Add 3 drops of reagent B and mix
  4. Wait for 7 minutes reaction time
  5. Insert the cuvette into the WINLAB Data Line photometer
  6. Start measurement – result is displayed directly in mg/l S²-

Tip for best results

The sample should be measured immediately after collection, as sulphide forms volatile hydrogen sulphide (H₂S). Do not shake or aerate the sample in order to avoid sulphide losses.
If H₂S can be detected by smell (from approx. 0.05 mg/l), a measurement is strongly recommended.

Important notes

  • Do not aerate or shake the sample – sulphide volatilizes as H₂S
  • Adhere exactly to the reaction time of 7 minutes
  • Avoid direct sunlight during the measurement
  • Wipe the cuvette with a lint-free cloth before measuring
  • Thoroughly rinse the test tube with the sample before each measurement
  • H₂S is toxic – work in a fume cupboard at high concentrations

Measuring range

Property Value
Measuring range 0.05 to 1.0 mg/l S²-
Resolution 0.01 mg/l
Method DPD method, photometric evaluation
Advantage of photometric measurement:
In contrast to the colorimetric method (color chart), the photometer provides exact numerical values with a higher resolution. Intermediate values are calculated automatically – ideal for documentation and quality assurance.

Number of possible destinations

You can carry out 100 measurements with one CALDUR® Test Set Sulfide.
This refers to the quantity of reagents contained.

Measuring accuracy and reproducibility

Resolution: 0.01 mg/l
Reproducibility: Very good if the application instructions are followed
Interference: Strongly reducing substances can influence the result. Compared to the colorimetric method, the photometric measurement is less susceptible to lightly stained samples, as the wavelength selectivity of the photometer better compensates for interfering background staining.

What to do if measured values are out of range?

Measured value > 1.0 mg/l

Verduction Execution Calculation of the measured value
1:1 5 ml sample + 5 ml sulfide-free water Measured value × 2
1:4 2 ml sample + 8 ml sulfide-free water Measured value × 5

Measured value < 0.05 mg/l

Measured value is below the detection limit. For more sensitive measurements, please contact our technical support.

Specifications at a glance

Property Value
Parameters Sulphide (S²- / H₂S)
Item number 31-073542
Method Photometric (DPD)
Measuring principle Photometric evaluation with WINLAB Data Line
Measuring range 0.05 to 1.0 mg/l S²-
Resolution 0.01 mg/l
Duration of analysis 7 minutes
Number of provisions 100
Number of reagents 2
Packaging Plastic bag
Scope of delivery
2 reagent bottles (reagent A, reagent B) with detailed labeling
1 round cuvette (10 ml)
Detailed operating instructions (DE/EN)
Safety data sheets for all reagents
Resealable plastic bag

Reagent details

Reagent Volume Shelf life Notes
Reagent A (DPD 1) 30 ml 24 months (24M) DPD reagent, shake before use
Reagent B (buffer) 10 ml 24 months (24M) Buffer solution, shake before use

Shelf life: The shelf life starts from the date of manufacture (printed on the bottle).
After opening, the reagents should be used within 12 months.
Store the test kit in a dry, cool place (10-25°C) and protected from direct sunlight.

Required accessories

For the photometric measurement you need a WINLAB Data Line photometer with the corresponding method for sulfide.
The photometer is not included in the test set and is available separately.

Additional information

Packaging

Plastic bag, Refill pack

Flyer
Operating instructions