End module for D version

  • End module for the escalator light curtain
  • terminates a transmitter/receiver chain
  • Transmitter or receiver
Article number: 
N/A Categories ,
Select the desired properties:
Quantity
iHow it works
  1. 1Add to your quote
  2. 2Review & submit your list
  3. 3Personal quote – within 24 h on business days

More safety on escalators: robust sensor, signalling and lighting technology – compliant with EN 115.

Made in GermanyEN 115 compliantISO 9001 (TÜV NORD)made in Hildesheim
Request a Quote

Private customers can also find our range in our partner store Ampha-Analyse.

Reagent for End module for D version:
See also:

End module for D version

The active end module terminates a transmitter or receiver chain in the D version. Unlike in the discontinued MO version, the end modules of the D version are active and part of the self-monitoring of the light curtain. One end module is required per chain – the matching type for the transmitter side and the receiver side, in standard or rev. version.

Features

  • automatic restart system according to EN 115:2008
  • safety light grid Cat. 4 / SIL 3, TÜV type-examined
  • up to 99 light barriers per escalator side (approx. 30 m)
  • self-monitoring and self-configuring
  • independent of ambient light, no wearing parts
  • protection class IP67, temperature range −20 … +65 °C
  • Original RUDOLPH design

Areas of application

Railway stations / platforms
Airports
Underground / metro
Shopping centres
Public buildings
Hotels
Office buildings
Trade fairs / congresses
Car parks

Field of use

Automatic restart systems (WBS) are used on escalators and moving walks in public and commercial passenger transport and automatically release the unit again after an emergency stop as soon as nobody is on it any more. The D version is designed for escalators made by Kone and Otis.

Operating principle

The light curtain uses up to 99 light barriers to create a vertical safety light grid across the escalator. Each light barrier consists of a transmitter module and a receiver module; if a person interrupts a light beam, the TLCU central unit detects the occupancy and withholds the release. The system works independently of ambient light and is self-monitoring and self-configuring according to EN 115:2008 (Cat. 4 / SIL 3).

Installation

  1. Fit the end module to the free end of the transmitter or receiver chain.
  2. One active end module per chain – the matching type for the transmitter side and the receiver side.

Important notes

  • One active end module per chain – the matching type for the transmitter side and the receiver side.
  • Install only when de-energised.

Technical data

Parameter Value
Standard EN 115:2008
Safety level Cat. 4 / SIL 3 (EN 61508, EN 954-1)
Testing TÜV type-examined
Protection class IP67
Temperature range −20 … +65 °C
Design Original RUDOLPH
Function active chain termination
Module type Transmitter / receiver
Version Standard / rev.

Additional information

Module Type

Receiver, Transmitter

Version

Standard, rev.

Flyer
Operating instructions