Adapter cable for E version
- Adapter cable for the escalator light curtain
- connects the module chain to the central unit
- Transmitter, receiver or pair

Private customers can also find our range in our partner store Ampha-Analyse.
Reagent for Adapter cable for E version:
See also:
Adapter cable for E version
The adapter cable (4 m) connects the module chains of the E version to the TLCU22-04 central unit. Available for the transmitter side, the receiver side or as a pair (transmitter + receiver). The matching adapter cable is required for each escalator side.
Features
- automatic restart system according to EN 115:2008
- safety light grid Cat. 4 / SIL 3, TÜV type-examined
- up to 99 light barriers per escalator side (approx. 30 m)
- self-monitoring and self-configuring
- independent of ambient light, no wearing parts
- protection class IP67, temperature range −20 … +65 °C
- Original RUDOLPH design
Areas of application
Field of use
Automatic restart systems (WBS) are used on escalators and moving walks in public and commercial passenger transport and automatically release the unit again after an emergency stop as soon as nobody is on it any more. The E version is designed for escalators made by Schindler and ThyssenKrupp and is recommended for new installations.
Operating principle
The light curtain uses up to 99 light barriers to create a vertical safety light grid across the escalator. Each light barrier consists of a transmitter module and a receiver module; if a person interrupts a light beam, the TLCU central unit detects the occupancy and withholds the release. The system works independently of ambient light and is self-monitoring and self-configuring according to EN 115:2008 (Cat. 4 / SIL 3).
Connection
- Connect the adapter cable to the end of the module chain.
- Connect the other end to the TLCU22-04 central unit.
- Use either transmitter, receiver or pair (transmitter + receiver) for each escalator side.
Important notes
- Use the matching type (transmitter/receiver) for each escalator side.
- Connect only to the TLCU22-04 central unit.
- Work only when de-energised.
Technical data
| Parameter | Value |
|---|---|
| Standard | EN 115:2008 |
| Safety level | Cat. 4 / SIL 3 (EN 61508, EN 954-1) |
| Testing | TÜV type-examined |
| Protection class | IP67 |
| Temperature range | −20 … +65 °C |
| Design | Original RUDOLPH |
| Function | Connection module chain → central unit |
| Cable length | 4 m |
| Connection | Central unit TLCU22-04 |
| Version | Transmitter / receiver / pair |
Additional information
| Module Type | Receiver, Transmitter, Transmitter + receiver |
|---|
Flyer
Operating instructions
Similar articles:
Related products
-
Adapter cable for D version
- Adapter cable for the escalator light curtain
- connects the module chain to the central unit
- Transmitter or receiver
-
External service displayExternal service display. The external service display serves to provide an extended view of a central unit’s display. Thanks to the cable, the external service display can be positioned optimally to read the status during a service operation on an escalator. -
Receiver C version
Receiver C Version. Receiver module of the light curtain system (C version, ThyssenKrupp/Schindler). Original RUDOLPH design.