Private customers can also find our range in our partner store Ampha-Analyse.
Reagent for CALDUR® MEKO – Photometric:
See also:
CALDUR® MEKO test set – Photometric
What is MEKO measured for?
MEKO (methyl ethyl ketoxime) is an oxygen binding agent that is used as an alternative to DEHA and sodium sulphite in steam boiler systems. It has the advantage that it remains stable even at high temperatures and does not form any decomposition products that contaminate the steam.
Precise dosing of MEKO is crucial for optimum corrosion protection. The photometric measurement enables an objective and precise determination of the concentration.
MEKO is preferably used in high-pressure steam boilers and in systems where steam cleanliness is particularly important.
How does the test set work?
The CALDUR® MEKO Test Set – Photometric is based on the ferrozine method. The reagents form a color complex with MEKO, the concentration of which is determined photometrically using the WINLAB Data Line photometer.
Advantages of the CALDUR® test set
Measuring range 0.5 – 10 mg/l MEKO
Covers the practical dosing range
100 provisions per set
Economical for regular checks
High precision due to photometric evaluation
Objective measurement results for optimum dosing
Adapted to WINLAB Data Line photometer
Optimum compatibility
Areas of application
Pond / lake
Groundwater / well water
Drinking / tap water
Aquaristics
Pool / Swimming pool
Industrial processing
Boiler water
Food preparation
Waste water treatment
Carrying out the measurement:
Take a boiler water sample and allow to cool to room temperature
Fill the water sample into the test tube up to the mark
Add reagent A and mix
Add reagent B and mix
Wait for 8 minutes reaction time
Perform photometric measurement with WINLAB Data Line Photometer
Tip for best results
Boiler water samples must be cooled to room temperature before measurement. Hot samples falsify the result.
The sample should be measured as fresh as possible, as MEKO can oxidize in the air.
Important notes
Allow sample to cool to room temperature before measuring
Adhere exactly to the response time of 8 minutes
Do not confuse MEKO and DEHA – different test sets required
For values above 10 mg/l: dilute sample 1:1, measured value × 2
Requires WINLAB Data Line photometer (Art. 37-000100)
Measuring range
Property
Value
Measuring range
0.5 – 10 mg/l MEKO
Resolution
0.1 mg/l
Number of possible destinations
With one CALDUR® Test Set MEKO Photometric you can carry out 100 measurements.
This refers to the quantity of reagents contained.
Recommended dosing ranges
Application
Recommended MEKO content
Low pressure boiler (< 20 bar)
1 – 3 mg/l MEKO
Medium pressure boiler (20-60 bar)
0.5 – 2 mg/l MEKO
High pressure boiler (> 60 bar)
0.5 – 1 mg/l MEKO
Note:
The optimum dosage depends on the type of system, operating pressure and oxygen content. Consult the water chemist or the dosing system documentation for system-specific target values.
Specifications at a glance
Property
Value
Parameters
MEKO (methyl ethyl ketoxime, C₄H₉NO)
Item number
31-073402
Method
Photometric (ferrozine)
Measuring principle
Photometric measurement with WINLAB Data Line Photometer
Measuring range
0.5 to 10 mg/l MEKO
Duration of analysis
8 minutes
Number of provisions
100
Number of reagents
2
Packaging
Plastic bag
Scope of delivery
2 reagent bottles (reagent A, reagent B) with detailed labeling
1 test tube with scale
Detailed operating instructions (DE/EN)
Safety data sheets for all reagents
Resealable plastic bag
Reagent details
Reagent
Volume
Shelf life
Notes
Reagent A (ferrozine)
30 ml
24 months (24M)
Ferrozine reagent, shake before use
Reagent B (reducing agent)
10 ml
24 months (24M)
Shake before use
Shelf life: The shelf life starts from the date of manufacture (printed on the bottle).
After opening, the reagents should be used within 12 months.
Store the test kit in a dry, cool place (10-25°C) and protected from direct sunlight.