CALDUR® Molybdenum – Photometric
Molybdenum determination in water using a photometer (2.5-100 mg/l Mo)

Private customers can also find our range in our partner store Ampha-Analyse.
Reagent for CALDUR® Molybdenum – Photometric:
See also:
CALDUR® Molybdenum Test Set – Photometric
What is Molybdenum measured for?
Molybdenum (Mo) is used in water treatment as a corrosion inhibitor, especially in closed cooling circuits and heating systems. The correct dosage is crucial for effective corrosion protection while at the same time avoiding overdosing.
Depending on the type of system, typical target values are between 5 and 50 mg/l Mo. Photometric measurement enables precise monitoring of the dosage.
How does the test set work?
The CALDUR® Molybdenum test set is based on the thioglycolic acid method. The reagent forms a color complex with molybdenume, the concentration of which is precisely determined with the WINLAB Data Line photometer.
Advantages of the CALDUR® test set
- Large measuring range 2.5 – 100 mg/l Mo
Covers the entire practical dosing range
- 120 provisions per set
Economical for regular checks
- High precision due to photometric evaluation
Objective, reproducible measurement results with the WINLAB Data Line
- Only 1 reagent required
Quick and easy to carry out in 4 minutes
Areas of application
Carrying out the measurement:
- Fill water sample into round cuvette up to the mark
- Add reagent and mix
- Wait for 4 minutes reaction time
- Insert the cuvette into the WINLAB Data Line photometer and start the measurement
Important notes
- Adhere exactly to the reaction time of 4 minutes
- For values above 100 mg/l: dilute the sample and convert the measured value
- Wipe the cuvette with a lint-free cloth before measuring
- Requires WINLAB Data Line Photometer (sold separately)
Measuring range
| Property | Value |
|---|---|
| Measuring range | 2.5 – 100 mg/l Mo |
| Resolution | 0.1 mg/l |
Number of possible destinations
With a CALDUR® Molybdenum Photometric test kit you can carry out 120 measurements.
Specifications at a glance
| Property | Value |
|---|---|
| Parameters | Molybdenum (Mo) |
| Item number | 31-073672 |
| Method | Photometric (thioglycolic acid) |
| Measuring principle | Photometric measurement with WINLAB Data Line Photometer |
| Measuring range | 2.5 to 100 mg/l Mo |
| Analysis time | 4 minutes |
| Number of provisions | 120 |
| Number of reagents | 1 |
| Packaging | Plastic bag |
Additional information
| Packaging | Plastic bag, Refill pack |
|---|---|
| Product category | Testset |
Flyer
Operating instructions
Similar articles:
Related products
-
CALDUR® pH 2-5 – Colorimetric
pH determination in the acidic range using a color chart (pH 2-5) -
CALDUR® Residual hardness RG 10 – Limit value
Residual hardness limit value determination in the water (limit value: 0.1 °dH) -
CALDUR® Sulfide – Colorimetric
Determination of sulphide in water using a color chart (0.05-1.0 mg/l S²-)