— Online analysers
SYCON in comparison
Find the right analyser for your application.
Features
- How it works:
- Limit value:
- Parameters:
- Units:
- Reagent consumption:
- Measuring point/range:
(see reagent)
- Fully automatic operation
- BoB – FunctionalityThe analyser shows if there is enough reagent for at least the next 72 hours.
- Diagnostic programme
- Analysis at set times
- Analysis after a set water volume
- Measured value log on SD card
- Modbus RTU interface
- Analogue output (4 ... 20 mA)
Relay functions- Limit value 1
- Limit value 2
- Analysis active / cooling water
- Ready for operationWhen the analyser is switched on, one relay switches. This shows an external control system whether the device is ready for operation or whether there is a fault such as a device malfunction, power failure or line defect.
- BoB warning
Input functions- Flow monitor
- Interval resetRecommended for duplex water softeners. When the system switches to the other softener, this input stops the running analysis. This ensures that the measurement result is always assigned to the correct system by the control unit.
- External analysis start
- External analysis stop
- Water meter
All analysers
- BASIC -

SYCON 2602
- Limit value device
The analyser checks if the water hardness is above or below a limit value (OK / not OK).
The reagent sets the limit value.
- set by the reagent
- Total hardness, carbonate hardness
- °dH, °f, °e, ppm, mmol/l, °Ж
- < 0.1 ml / analysis
min. 5000 analyses / 500 ml - Reagent
- The analyser shows if there is enough reagent for at least the next 72 hours.
- When the analyser is switched on, one relay switches. This shows an external control system whether the device is ready for operation or whether there is a fault such as a device malfunction, power failure or line defect.
- Recommended for duplex water softeners. When the system switches to the other softener, this input stops the running analysis. This ensures that the measurement result is always assigned to the correct system by the control unit.
SYCON 2602
- STANDARD -
SYCON 2702
- Titration device
The analyser measures the exact water hardness in a measuring range.
The reagent sets the measuring range. - an adjustable limit value
- Total hardness, carbonate hardness
- °dH, °f, °e, ppm, mmol/l, °Ж
- < 0.05 ml / analysis
min. 10000 analyses / 500 ml - Reagent
- The analyser shows if there is enough reagent for at least the next 72 hours.
- When the analyser is switched on, one relay switches. This shows an external control system whether the device is ready for operation or whether there is a fault such as a device malfunction, power failure or line defect.
- Recommended for duplex water softeners. When the system switches to the other softener, this input stops the running analysis. This ensures that the measurement result is always assigned to the correct system by the control unit.
SYCON 2702
- PREMIUM -
SYCON 2802
- Titration device
The analyser measures the exact water hardness in a measuring range.
The reagent sets the measuring range. - Two adjustable limit values
- Total hardness, carbonate hardness
- °dH, °f, °e, ppm, mmol/l, °Ж
- < 0.05 ml / analysis
min. 10000 analyses / 500 ml - Reagent
- The analyser shows if there is enough reagent for at least the next 72 hours.
- When the analyser is switched on, one relay switches. This shows an external control system whether the device is ready for operation or whether there is a fault such as a device malfunction, power failure or line defect.
- Recommended for duplex water softeners. When the system switches to the other softener, this input stops the running analysis. This ensures that the measurement result is always assigned to the correct system by the control unit.
SYCON 2802
Features:
- How it works:
- Limit value:
- Parameters:
- Units:
- Reagent consumption:
- Measuring point/range:
(see reagent)
- Fully automatic operation
- BoB – Functionality1
- Diagnostic programme
- Analysis at set times
- Analysis after a set water volume
- Measured value log on SD card
- Modbus RTU interface
- Analogue output (4 ... 20 mA)
Relay functions- Limit value 1
- Limit value 2
- Analysis active / cooling water
- Ready for operation
- BoB warning
Input functions- Flow monitor
- Interval reset2
- External analysis start
- External analysis stop
- Water meter
All analysers
- BASIC -

SYCON 2602
- Limit value device
The analyser checks if the water hardness is above or below a limit value (OK / not OK).
The reagent sets the limit value. - set by the reagent
- Total hardness, carbonate hardness
- °dH, °f, °e, ppm, mmol/l, °Ж
- < 0.1 ml / analysis
min. 5000 analyses / 500 ml - Reagent
View SYCON 2602
- STANDARD -
SYCON 2702
- Titration device
The analyser measures the exact water hardness in a measuring range.
The reagent sets the measuring range. - an adjustable limit value
- Total hardness, carbonate hardness
- °dH, °f, °e, ppm, mmol/l, °Ж
- < 0.05 ml / analysis
min. 10000 analyses / 500 ml - Reagent
View SYCON 2702
- PREMIUM -
SYCON 2802
- Titration device
The analyser measures the exact water hardness in a measuring range.
The reagent sets the measuring range. - Two adjustable limit values
- Total hardness, carbonate hardness
- °dH, °f, °e, ppm, mmol/l, °Ж
- < 0.05 ml / analysis
min. 10000 analyses / 500 ml - Reagent
View SYCON 2802