Connection modules for C version

Connection modules for C-Version. Connection modules for the C-Version light curtain. Original RUDOLPH design.
Article number: 
depends on selection Categories ,
Select the desired properties:
Quantity
iHow it works
  1. 1Add to your quote
  2. 2Review & submit your list
  3. 3Personal quote – within 24 h on business days

More safety on escalators: robust sensor, signalling and lighting technology – compliant with EN 115.

Made in GermanyEN 115 compliantISO 9001 (TÜV NORD)made in Hildesheim
Request a Quote

Private customers can also find our range in our partner store Ampha-Analyse.

Reagent for Connection modules for C version:
See also:

Connection modules for C-Version

The connection modules connect the transmitter and receiver modules of the C-Version light curtain system.

Part of the automatic restart system (WBS)

The light curtain is part of the automatic restart system (WBS) for escalators: transmitter and receiver modules monitor the presence of persons on the unit in accordance with EN 115 and automatically release the escalator again after an emergency stop. The C-Version is the predecessor system for escalators from ThyssenKrupp and Schindler.

Features

  • Original RUDOLPH design

Areas of application

Railway stations / platforms
Airports
Underground / metro
Shopping centres
Public buildings
Hotels
Office buildings
Trade fairs / congresses
Car parks

Field of use

Automatic restart systems (WBS) are used on escalators and moving walks in public and commercial passenger transport and automatically release the unit again after an emergency stop as soon as nobody is on it any more. The C version is designed for escalators made by Schindler and ThyssenKrupp (Original RUDOLPH design); for new installations we recommend the current E version.

Operating principle

The light curtain uses up to 99 light barriers to create a vertical safety light grid across the escalator. Each light barrier consists of a transmitter module and a receiver module; if a person interrupts a light beam, the TLCU central unit detects the occupancy and withholds the release. The system works independently of ambient light and is self-monitoring and self-configuring according to EN 115:2008 (Cat. 4 / SIL 3).

Installation

  1. Fit the connection module between two module chains.
  2. Connect the chains to form an automatic restart system with up to 99 light barriers.
  3. Use the matching type for the transmitter side and the receiver side.

Important notes

  • Installation/connection only by trained personnel and when de-energised.

Technical data

Parameter Value
Standard EN 115:2008
Safety level Cat. 4 / SIL 3 (EN 61508, EN 954-1)
Testing TÜV type-examined
Protection class IP67
Temperature range −20 … +65 °C
Design Original RUDOLPH
Function connects module chains
Module type Transmitter / receiver

Additional information

Module Type

Receiver, Transmitter

Flyer
Operating instructions