Private customers can also find our range in our partner store Ampha-Analyse.
Reagent for Transmitter/receiver module for E version:
See also:
Transmitter/receiver module for E version
Transmitter and receiver modules form the individual light barriers of the light curtain in the E version (escalators from Schindler and ThyssenKrupp). The E version is a further development of the proven C version: the modules are easily connected with plug connectors to form long module chains, and no additional connecting elements are needed. This results in a low risk of failure, and individual modules can be replaced quickly.
Use the module type to select transmitter or receiver. Recommended for new installations.
Features
automatic restart system according to EN 115:2008
safety light grid Cat. 4 / SIL 3, TÜV type-examined
up to 99 light barriers per escalator side (approx. 30 m)
self-monitoring and self-configuring
independent of ambient light, no wearing parts
protection class IP67, temperature range −20 … +65 °C
Original RUDOLPH design
Areas of application
Railway stations / platforms
Airports
Underground / metro
Shopping centres
Public buildings
Hotels
Office buildings
Trade fairs / congresses
Car parks
Field of use
Automatic restart systems (WBS) are used on escalators and moving walks in public and commercial passenger transport and automatically release the unit again after an emergency stop as soon as nobody is on it any more. The E version is designed for escalators made by Schindler and ThyssenKrupp and is recommended for new installations.
Operating principle
The light curtain uses up to 99 light barriers to create a vertical safety light grid across the escalator. Each light barrier consists of a transmitter module and a receiver module; if a person interrupts a light beam, the TLCU central unit detects the occupancy and withholds the release. The system works independently of ambient light and is self-monitoring and self-configuring according to EN 115:2008 (Cat. 4 / SIL 3).
Installation
Fix the module with a stainless steel holder on the intended side of the escalator (transmitter and receiver sides opposite each other).
Integrate the module into the transmitter or receiver chain using the plug connector.
Check the alignment with the opposite module.
Maintenance & cleaning
Regularly inspect the modules and optical surfaces visually.
Clean dirty optics with a soft, lint-free cloth – no aggressive cleaning agents.
Check the status display of the central unit; faults are displayed and output.
No wearing parts – very low maintenance effort; defective modules can be replaced individually with minimal tools.
Important notes
Align transmitter and receiver exactly opposite each other.
One stainless steel holder is required per module.
Only use the version that matches the escalator type.