Light curtain E version
- Safety light curtain for escalators
- automatic release after emergency stop (EN 115)
- current version – recommended for new systems
Item no.:
Categories E version, Light curtain
Private customers can also find our range in our partner store Ampha-Analyse.
Reagent for Light curtain E version:
See also:
Light curtain E version
The automatic restart system (WBS) in the E version is the RLS Wacon light curtain for escalators and moving walks made by Schindler and ThyssenKrupp. It automatically releases an escalator again after an emergency stop has been activated and monitors the presence of people on the unit in accordance with EN 115.
The E version is a further development of the proven C version and is recommended for new installations. The light curtain consists of up to 99 light barriers, which are easily connected with plug connectors to form long module chains – no additional connecting elements are required. This results in a low risk of failure, and individual modules can be replaced easily and quickly. Each chain is terminated by an active end module; evaluation is performed by the TLCU22-04 central unit.
Features
- automatic restart system according to EN 115:2008
- safety light grid Cat. 4 / SIL 3, TÜV type-examined
- up to 99 light barriers per escalator side (approx. 30 m)
- self-monitoring and self-configuring
- independent of ambient light, no wearing parts
- protection class IP67, temperature range −20 … +65 °C
- Original RUDOLPH design
Note: The TLCU22-04 central unit is required for evaluation and is included in the system. One stainless steel holder is required per module.
Areas of application
Field of use
Automatic restart systems (WBS) are used on escalators and moving walks in public and commercial passenger transport and automatically release the unit again after an emergency stop as soon as nobody is on it any more. The E version is designed for escalators made by Schindler and ThyssenKrupp and is recommended for new installations.
Operating principle
The light curtain uses up to 99 light barriers to create a vertical safety light grid across the escalator. Each light barrier consists of a transmitter module and a receiver module; if a person interrupts a light beam, the TLCU central unit detects the occupancy and withholds the release. The system works independently of ambient light and is self-monitoring and self-configuring according to EN 115:2008 (Cat. 4 / SIL 3).
Installation
- Mount transmitter and receiver modules opposite each other on both sides of the escalator – one stainless steel holder per module.
- Connect the modules with plug connectors to form the transmitter and receiver chains (no additional connecting elements needed).
- Fit one active end module at the end of each chain.
- Connect the transmitter and receiver chains to the TLCU22-04 central unit via the matching adapter cables (4 m).
- Switch on the system – the light curtain configures itself and shows its status on the central unit.
Maintenance & cleaning
- Regularly inspect the modules and optical surfaces visually.
- Clean dirty optics with a soft, lint-free cloth – no aggressive cleaning agents.
- Check the status display of the central unit; faults are displayed and output.
- No wearing parts – very low maintenance effort; defective modules can be replaced individually with minimal tools.
Tip for service work
With the external service display (art. no. 80-200231), the status of the central unit can be read conveniently directly at the escalator during service work – it can be positioned optimally via a 4 m cable that can be extended up to 20 m.
Important notes
- Only use the version that matches the escalator type – E version for Schindler and ThyssenKrupp.
- Align transmitter and receiver exactly opposite each other.
- One stainless steel holder is required per module.
- The TLCU22-04 central unit is required for evaluation.
- Work on the system only by trained personnel and when de-energised.
Technical data
| Parameter | Value |
|---|---|
| Standard | EN 115:2008 |
| Safety level | Cat. 4 / SIL 3 (EN 61508, EN 954-1) |
| Testing | TÜV type-examined |
| Protection class | IP67 |
| Temperature range | −20 … +65 °C |
| Design | Original RUDOLPH |
| Light barriers | max. 99 per escalator side (approx. 30 m) |
| Module connection | Plug connector (module chains) |
| Evaluation | Central unit TLCU22-04 |
| End module | active |
Additional information
Flyer
Operating instructions
Similar articles:
Related products
-
Adapter cable for E version
- Adapter cable for the escalator light curtain
- connects the module chain to the central unit
- Transmitter, receiver or pair
-
Transmitter/receiver module for E version
- Module for the escalator light curtain
- forms one light barrier of the safety grid
- Transmitter or receiver selectable
-
Conversion adapter
- Conversion adapter for the escalator light curtain
- modernises existing systems without replacing cables
- saves time and costs