Adapter cable for C version

Adapter Cable for C-Version. Adapter cable for the modules of the light curtain (C-Version). Original RUDOLPH design.
Article number: 
depends on selection Categories ,
Select the desired properties:
Quantity
iHow it works
  1. 1Add to your quote
  2. 2Review & submit your list
  3. 3Personal quote – within 24 h on business days

More safety on escalators: robust sensor, signalling and lighting technology – compliant with EN 115.

Made in GermanyEN 115 compliantISO 9001 (TÜV NORD)made in Hildesheim
Request a Quote

Private customers can also find our range in our partner store Ampha-Analyse.

Reagent for Adapter cable for C version:
See also:

Adapter Cable for C-Version

The adapter cable is used to connect the modules of the C-Version light curtain system.

Part of the standby restart circuit (WBS)

The light curtain is part of the standby restart circuit (WBS) for escalators: transmitter and receiver modules monitor the presence of persons on the unit in accordance with EN 115 and automatically release the escalator again after an emergency stop. The C-Version is the predecessor system for escalators from ThyssenKrupp and Schindler.

Features

  • Original RUDOLPH design

Areas of application

Railway stations / platforms
Airports
Underground / metro
Shopping centres
Public buildings
Hotels
Office buildings
Trade fairs / congresses
Car parks

Field of use

Automatic restart systems (WBS) are used on escalators and moving walks in public and commercial passenger transport and automatically release the unit again after an emergency stop as soon as nobody is on it any more. The C version is designed for escalators made by Schindler and ThyssenKrupp (Original RUDOLPH design); for new installations we recommend the current E version.

Operating principle

The light curtain uses up to 99 light barriers to create a vertical safety light grid across the escalator. Each light barrier consists of a transmitter module and a receiver module; if a person interrupts a light beam, the TLCU central unit detects the occupancy and withholds the release. The system works independently of ambient light and is self-monitoring and self-configuring according to EN 115:2008 (Cat. 4 / SIL 3).

Connection

  1. Connect the adapter cable to the end of the transmitter or receiver chain.
  2. Connect the other end to the TLCU22-04 central unit.
  3. Use either transmitter, receiver or pair for each escalator side.

Important notes

  • Use the matching type (transmitter/receiver) or the pair for each escalator side.
  • Connect only to the TLCU22-04 central unit.
  • Work only when de-energised.

Technical data

Parameter Value
Standard EN 115:2008
Safety level Cat. 4 / SIL 3 (EN 61508, EN 954-1)
Testing TÜV type-examined
Protection class IP67
Temperature range −20 … +65 °C
Design Original RUDOLPH
Function Connection module chain → central unit
Cable length 4 m
Connection Central unit TLCU22-04
Version Transmitter / receiver / pair

Additional information

Module Type

Receiver, Transmitter, Transmitter + receiver

Flyer
Operating instructions