Private customers can also find our range in our partner store Ampha-Analyse.
Iron is a naturally occurring element that can be found in almost all bodies of water and groundwater sources. Although iron is essential for the human body, too high a concentration in drinking water can lead to undesirable effects. Elevated iron levels cause a brownish discoloration of the water, a metallic taste and can lead to deposits in pipes and household appliances.
The limit value for drinking water in Germany is 0.2 mg/l (Drinking Water Ordinance). The CALDUR® Iron HRS test set is specially designed for measuring higher iron concentrations and is particularly suitable for industrial applications, boiler water and process water, where higher iron contents frequently occur.
Iron can enter the water from various sources: natural leaching from iron-containing rock layers, corrosion of iron pipes, industrial discharges or through iron-containing additives in water treatment. It is particularly important to monitor the iron content in steam boilers and cooling circuits, as increased concentrations can lead to corrosion and deposits.
The CALDUR® Iron HRS Test Set – Colorimetric works according to the proven O-phenanthroline method. O-phenanthroline (1,10-phenanthroline) forms an intense orange-red color complex with iron(II) ions, the intensity of which is proportional to the iron concentration. The reaction is highly specific for iron and enables reliable determination even at higher concentrations.
After a reaction time of 4 minutes, the measured value is determined by direct color comparison with a supplied 6-stage color chart. This colorimetric method enables fast and reliable on-site determination without the need for expensive laboratory equipment.
Perfect for boiler water, process water and applications with higher iron concentrations
Ideal for on-site use – saves time and enables immediate decisions
Cost-efficient for regular checks in industry and water treatment
Fewer work steps for faster results
Reliable and reproducible results according to a standardized procedure
Safe transportation and protection of reagents – durable and reliable
For best results, the water sample should be clear and free of suspended solids.
If the water is cloudy, pre-filtration with a filter paper (e.g. Whatman No. 1) is recommended.
| Measuring level | Description |
|---|---|
| 0.2 mg/l | Low concentration (slightly orange) |
| 0.5 mg/l | Slightly increased concentration (orange) |
| 1.0 mg/l | Increased concentration (clearly orange) |
| 2.5 mg/l | High concentration (intense orange) |
| 5.0 mg/l | Very high concentration (dark orange) |
| 10 mg/l | Very high concentration (red-brown) |
You can carry out 150 measurements with one CALDUR® iron HRS test set.
This refers to the quantity of reagents contained.
Readability: ± 1 color level
Reproducibility: Very good if the application instructions are followed
Interferences: Turbidity and coloration of the sample can influence the result (filter the sample if necessary).
| Dilution | Procedure | Calculation of the measured value |
|---|---|---|
| 1:1 | 5 ml sample + 5 ml distilled water | Measured value × 2 |
| 1:4 | 2 ml sample + 8 ml distilled water | Measured value × 5 |
| 1:9 | 1 ml sample + 9 ml distilled water | Measured value × 10 |
For concentrations below 0.2 mg/l, we recommend the CALDUR® Iron LR test set (measuring range 0.05-1.0 mg/l) or the Iron LRS test set (measuring range 0.01-0.5 mg/l) for even more sensitive measurements.
Reagent (O-phenanthroline)
| Property | Value |
|---|---|
| Parameters | Iron (Fe) – High Range |
| Item number | 31-072630 |
| Method | Colorimetric (O-phenanthroline) |
| Measuring principle | Color comparison with 6-stage color chart |
| Measuring range | 0.2 to 10 mg/l Fe |
| Color scale | 6 measuring levels (0.2 / 0.5 / 1.0 / 2.5 / 5.0 / 10 mg/l) |
| Analysis time | 4 minutes |
| Number of provisions | 150 |
| Number of reagents | 1 (O-phenanthroline reagent) |
| Packaging | Hinged lid box |
| Packaging size | 103 x 91 x 36 mm |
| weight | approx. 150 g |
| Scope of delivery |
|---|
| 1 reagent bottle (O-phenanthroline reagent) with detailed labeling |
| 1 test tube with 10 ml scale |
| 1 color card with 6 measuring levels |
| Detailed operating instructions (DE/EN) |
| Safety data sheets for all reagents |
| Robust hinged lid box (103 x 91 x 36 mm) |
| Reagent | Volume | Shelf life | Notes |
|---|---|---|---|
| Iron HRS Reagent | 15 ml | 48 months (48M) | O-phenanthroline solution, shake before use |
Shelf life: The shelf life starts from the date of manufacture (printed on the bottle).
After opening, the reagents should be used within 12 months.
Store the test kit in a dry, cool place (10-25°C) and away from direct sunlight.
| Packaging | Hinged lid box, Refill pack |
|---|