Private customers can also find our range in our partner store Ampha-Analyse.
The carbonate value (also known as the temporal value) describes the proportion of the water value that is caused by hydrogen carbonate ions (HCO₃-). Monitoring carbonate levels is crucial in many areas of water treatment:
The C25 Reagents are liquid color reagents for fully automatic water analysis with SYCON analyzers. The SYCON device automatically takes a water sample, precisely doses the Reagent and measures the resulting coloration photometrically.
Depending on the device mode, the system operates as a limit value monitor (SYCON 2602) or as a measuring range device (SYCON 2702, 2802) with continuous measured value output.
Customized selection for different applications
Flexible use with SYCON 2602, 2702 and 2802
Leak-free monitoring without manual intervention
Manufactured by RLS Wacon – Made in Germany
Consistently high precision with every delivery
Economical container sizes for every need
Only use indicator bottles with a capacity of 500 ml. They can be changed directly on the SYCON analyzer without tools.
| Reagent | Limit value (°dKH) | Measuring range (°dKH) | Article no. (1x 500 ml) | Item no. (4x 500 ml) |
|---|---|---|---|---|
| C25-1 | 1 | 0,30 – 7,5 | 32-086125 | 32-486125 |
| C25-1,5 | 1,5 | 0,45 – 11,5 | 32-086135 | 32-486135 |
| C25-2 | 2 | 0,60 – 15,0 | 32-086145 | 32-486145 |
| C25-3 | 3 | 0,90 – 22,5 | 32-086155 | 32-486155 |
Change to an Reagent with a higher limit value (e.g. from C25-1 to C25-2). The device must be reconfigured accordingly.
Change to a Reagent with a lower limit for more precise results in the low range.
| Property | Value |
|---|---|
| Parameters | Carbonate value (temporal hardness) |
| Series | C25 |
| Method | Colorimetric (photometric evaluation) |
| Measuring principle | Fully automatic Reagent dosing and color measurement |
| Base unit | °dKH |
| Available limit values | 1 / 1.5 / 2 / 3 °dKH |
| Number of variants | 4 concentration levels |
| Container size | 500 ml single bottle |
| Value pack | 4 × 500 ml |
| Shelf life | 24 months from date of manufacture |
| Manufacturer | RLS Wacon analytics GmbH, Hildesheim |
| Device | Operating mode | Status |
|---|---|---|
| SYCON 2602 | Limit value | Active |
| SYCON 2702 | Measuring range | Active |
| SYCON 2802 | Measuring range | Active |
| SYCON 2501 | Limit value + measuring range | Discontinued |
| SYCON 2502 | Limit value + measuring range | Terminated |
| SYCON 2800 | Measuring range | Discontinued |
Store in a cool, dry and dark place. Do not freeze. Protect from direct sunlight.
Shelf life: 24 months from date of manufacture (see label on the bottle). Use as soon as possible after opening.
All Reagents are manufactured in-house at RLS Wacon according to strict quality standards. Each batch is individually calibrated and tested – Made in Germany.
| Limit value/measuring range | 1, 1,5, 2, 3 |
|---|---|
| Packaging | 1x 500 ml, 4x 500 ml |