The PC 200 pre-cooler is used to take a water sample from a hot water pipe. By installing it in the sampling line and connecting a cold water line, samples such as boiler water, boiler feed water and condensate can be automatically monitored for quality. Our SYCON BOB online analyzer is used downstream of the sample cooler to determine the water hardness.
The special features of the PC series sample coolers include
The AC 100 sample cooler is used to take a water sample for manual analysis from a hot water pipe. By installing it in the sampling line and connecting a cold water line, samples such as boiler water, boiler feed water and condensate can be qualitatively monitored. The samples are then analyzed using our CALDUR test kits, for example.
The special features of the PC series sample coolers include
Parameters | Value / Range |
Weight | 2.4 kg without valves / 2.72 kg with valves |
Dimensions | Body 100 x 225 mm / cooling coil 2.6 m x 8 mm |
Material | Stainless steel 1.4571, electropolished |
Parameters | Value / Range |
Installation | Wall mounting in closed rooms |
Cooling water inlet | 8 mm |
Cooling water outlet | 1/2″ external thread |
Sample water input | 8 mm |
Sample water output | 8 mm |
Nominal pressure | 8 bar (open outlets) |
Cooling coil | 16 bar |
Fastening | 2-fold, spacing 54 mm, screw diameter 4 mm |
Item number | Article description |
30-012110 | Hot water valve type HWV 100, fine control valve made of brass, PN 50 bar, 100°C |
30-012121 | Cold water valve type KWV 150, 1/4” ball valve nickel-plated brass with screw connections for 8 mm pipe |
Series | LIMES, SYCON |
---|---|
Product category | Accessories, Intercooler |