Private customers can also find our range in our partner store Ampha-Analyse.
Reagent for Total hardness H25 series:
See also:
Reagent total value H25 series
What is the total value measured for?
The total hardness (also water hardness) describes the concentration of alkaline earth ions dissolved in the water, in particular calcium and magnesium. Reliable hardness measurement is indispensable in many areas of water treatment:
Boiler feed water and steam generation: Even small residues lead to limescale deposits (scaling), which can impair the heat transfer and cause damage to the system.
Ion exchanger monitoring: Precise hardness measurement enables early detection of resin breakthroughs and needs-based regeneration.
Reverse osmosis systems: Continuous control of permeate quality to protect downstream processes.
Cooling water systems: Prevention of deposits and corrosion in cooling towers and heat exchangers.
Drinking and process water: Monitoring of water quality in accordance with operational specifications.
In industrial water treatment, precise and continuous monitoring of residual hardness is crucial for safe, efficient and economical plant operation.
How does the Reagent work?
The H25 Reagents are liquid color reagents for fully automatic water analysis with analyzers of the SYCON series from RLS Wacon. The measuring principle is based on a colorimetric reaction:
The analyzer automatically takes a water sample at freely configurable intervals, precisely doses the Reagent and measures the resulting coloration photometrically. The color intensity is directly proportional to the concentration of hardness in the water.
Fully automatic sampling and evaluation eliminates operating errors and ensures seamless 24/7 monitoring – even at measuring points that are difficult to access.
Advantages of the H25 series
11 concentration levels from 0.02 to 10 °dH
Precise selection for every measuring range and limit value
Fully automatic measurement with SYCON analyzers
24/7 monitoring without manual intervention
Compatible with SYCON 2602, 2702, 2802 and SYCON BoB
Flexible applications for limit value and measuring range devices
High-quality raw materials and our own recipe
Manufactured by RLS Wacon – Made in Germany
In-house production and individual batch calibration
Consistently high quality and precision with every delivery
24 months shelf life from production
Cost-efficient stockpiling and flexible warehousing
Available as single bottle (500 ml) and value pack (4 × 500 ml)
Economical container sizes for every need
Areas of application
Boiler feed water
Steam generation
Ion exchanger
Reverse osmosis
Cooling water
Drinking water treatment
Industrial water treatment
Power plants
Pharmaceuticals / ultrapure water
Changing the indicator on the device
Only use indicator bottles with a capacity of 500 ml. They can be changed directly on the SYCON analyzer without tools.
Procedure
Wearing protective gloves is recommended.
Deactivate automatic mode on the device.
Loosen the screw cap on the bottle and insert a new indicator bottle – absorb any drips.
Flush the measuring chamber (menu > Service > Manual flushing).
Pump the Reagent into the measuring chamber (menu > Service > Pump Reagent) until the Reagent arrives free of bubbles. Confirm with [OK].
Indicates whether a full bottle has been inserted (fill level indicator).
Rinse the measuring chamber again and test the analysis procedure by starting an analysis.
Activate automatic mode again.
Important notes
Check the expiration date on the bottle before use – only use Reagent that has not expired.
When changing to a different measuring range, the device must be reconfigured accordingly.
Measuring range
Reagent
Limit value (°dH)
Measuring range (°dH)
Article no. (1x 500 ml)
Item no. (4x 500 ml)
H25-0,02
0,02
0,012 – 0,12
32-084115
32-484115
H25-0,05
0,05
0,02 – 0,2
32-084125
32-484125
H25-0,1
0,1
0,03 – 0,3
32-084135
32-484135
H25-0,2
0,2
0,06 – 0,6
32-084145
32-484145
H25-0,3
0,3
0,09 – 0,9
32-084155
32-484155
H25-0,5
0,5
0,15 – 1,5
32-084165
32-484165
H25-1
1
0,3 – 3
32-084175
32-484175
H25-2
2
0,6 – 6
32-084185
32-484185
H25-3
3
0,9 – 9
32-084195
32-484195
H25-5
5
1,5 – 15
32-084205
32-484205
H25-10
10
3 – 30
32-084215
32-484215
Unit conversion:
The measuring ranges are given in °dH (German degrees of hardness). Conversion factors: 1 °dH = 17.8 ppm CaCO₃ = 1.78 °f (French degrees of hardness) = 1.25 °e (English degrees of hardness).
SYCON BoB compatibility
The following Reagents are compatible with the SYCON BoB:
Reagent
BoB limit value (°dH)
BoB limit value (mmol/l)
H25-0,05
0,03
0,005
H25-0,1
0,05
0,01
What to do if measured values are out of range?
Measured value above the measuring range
Change to an Reagent with a higher limit value. The device must be reconfigured accordingly.
Measured value below the measuring range
Change to an Reagent with a lower limit value. This enables a more precise measurement in the low concentration range.
Specifications at a glance
Property
Value
Parameters
Total hardness (water hardness)
Series
H25
Method
Colorimetric (photometric evaluation)
Measuring principle
Fully automatic Reagent dosing and color measurement
Store in a cool, dry and dark place. Do not freeze. Protect from direct sunlight. Shelf life: 24 months from date of manufacture (see label on the bottle). Use as soon as possible after opening.
Quality control
All Reagents are manufactured in-house at RLS Wacon to strict quality standards. Each batch is individually calibrated and tested before it leaves the factory. Production is carried out exclusively with high-quality raw materials according to our own recipe – Made in Germany.
We use cookies and analytics services (e.g. Google Analytics) to improve our website. Technically necessary services are always on. You can accept or decline optional services. More in the privacy policy