Traffic light S7400
The S7400 traffic light is a single-colour signal light for escalators and moving walks – available in green or red and optionally with function monitoring. It is designed for installation in a square column or base.
Use at escalators and moving walks
Signal lights from RLS Wacon show passengers whether the unit is cleared or blocked: green clears the direction of travel, red signals that the unit is blocked. The bright, homogeneous LED illumination remains clearly visible even in ambient light; robust LED technology ensures long, low-maintenance operation.
Features
single-colour signal light, colour selectable (green or red)
optionally with function monitoring
for square column or base
front lens Ø 74 mm
wide input voltage range
robust and durable (LED service life 50,000 h)
Optional: function monitoring
On request, this product is available with function monitoring: the device continuously checks its own function and automatically reports a failure – such as a defective LED – via a separate output to a remote diagnostics system or the control room. Faults are detected immediately without an on-site check – this increases the availability of the unit and reduces maintenance effort.
Areas of application
Railway stations / platforms
Airports
Underground / metro
Shopping centres
Public buildings
Hotels
Office buildings
Trade fairs / congresses
Car parks
Field of use
The signal light is mounted on the access side of escalators and moving walks and shows passengers whether the unit is cleared (green) or blocked (red).
Operating principle
The display uses backlit LEDs and offers high optical contrast with homogeneous illumination and low power consumption. Nothing is visible on the display when de-energised. Optionally, the traffic light is available with function monitoring for connection to a remote diagnostics system.
Installation
Insert the traffic light into the cut-out provided in the square column or base plate.
Connect the operating voltage (see Technical data).
For versions with function monitoring, connect the monitoring output to the remote diagnostics system.
Maintenance & cleaning
Regularly inspect the front lens and display visually.
Clean the front lens with a soft cloth if dirty – the front lens is replaceable.