Transmitter and receiver chains for C version
Transmitter and receiver chains for C-Version. The 9-module receiver chain C-Version consists of a 9-module receiver line equipped with receiver modules.

Private customers can also find our range in our partner store Ampha-Analyse.
Reagent for Transmitter and receiver chains for C version:
See also:
Transmitter and receiver chains for C-Version
The 9-module receiver chain C-Version consists of a 9-module receiver line equipped with receiver modules.
Part of the automatic restart system (WBS)
The light curtain is part of the automatic restart system (WBS) for escalators and moving walks: in accordance with EN 115, transmitter and receiver modules monitor the presence of people on the unit and automatically release the escalator again after an emergency stop. The signals are evaluated by the central unit. The D-Version is designed for Otis and Kone escalators, the E-Version for ThyssenKrupp and Schindler.
Features
- Original RUDOLPH design
Areas of application
Field of use
Automatic restart systems (WBS) are used on escalators and moving walks in public and commercial passenger transport and automatically release the unit again after an emergency stop as soon as nobody is on it any more. The C version is designed for escalators made by Schindler and ThyssenKrupp (Original RUDOLPH design); for new installations we recommend the current E version.
Operating principle
The light curtain uses up to 99 light barriers to create a vertical safety light grid across the escalator. Each light barrier consists of a transmitter module and a receiver module; if a person interrupts a light beam, the TLCU central unit detects the occupancy and withholds the release. The system works independently of ambient light and is self-monitoring and self-configuring according to EN 115:2008 (Cat. 4 / SIL 3).
Installation
- Select the pre-assembled 9-module, 10-module or 11-module chain for the transmitter or receiver side.
- Mount the chain on the escalator side (one holder per module).
- Combine chains via connection modules; terminate the end of the chain with an inactive end module; connect to the central unit via adapter cable.
Important notes
- Installation/connection only by trained personnel and when de-energised.
Technical data
| Parameter | Value |
|---|---|
| Standard | EN 115:2008 |
| Safety level | Cat. 4 / SIL 3 (EN 61508, EN 954-1) |
| Testing | TÜV type-examined |
| Protection class | IP67 |
| Temperature range | −20 … +65 °C |
| Design | Original RUDOLPH |
| Function | pre-assembled module chain |
| Chain length | 9 / 10 / 11 modules |
| Module type | Transmitter / receiver |
Additional information
| Module Type | Receiver, Transmitter |
|---|
Flyer
Operating instructions
Similar articles:
Related products
-
Transmitter/receiver module for D version
- Module for the escalator light curtain
- forms one light barrier of the safety grid
- Transmitter or receiver selectable
-
Adapter cable for D version
- Adapter cable for the escalator light curtain
- connects the module chain to the central unit
- Transmitter or receiver
-
Connection modules for C version
Connection modules for C-Version. Connection modules for the C-Version light curtain. Original RUDOLPH design.