Private customers can also find our range in our partner store Ampha-Analyse.
MEKO (methyl ethyl ketoxime) is an oxygen binding agent that is used as an alternative to DEHA and sodium sulphite in steam boiler systems. It has the advantage that it remains stable even at high temperatures and does not form any decomposition products that contaminate the steam.
Precise dosing of MEKO is crucial for optimum corrosion protection. The photometric measurement enables an objective and precise determination of the concentration.
MEKO is preferably used in high-pressure steam boilers and in systems where steam cleanliness is particularly important.
The CALDUR® MEKO Test Set – Photometric is based on the ferrozine method. The reagents form a color complex with MEKO, the concentration of which is determined photometrically using the WINLAB Data Line photometer.
Covers the practical dosing range
Economical for regular checks
Objective measurement results for optimum dosing
Optimum compatibility
Boiler water samples must be cooled to room temperature before measurement. Hot samples falsify the result.
The sample should be measured as fresh as possible, as MEKO can oxidize in the air.
| Property | Value |
|---|---|
| Measuring range | 0.5 – 10 mg/l MEKO |
| Resolution | 0.1 mg/l |
With one CALDUR® Test Set MEKO Photometric you can carry out 100 measurements.
This refers to the quantity of reagents contained.
| Application | Recommended MEKO content |
|---|---|
| Low pressure boiler (< 20 bar) | 1 – 3 mg/l MEKO |
| Medium pressure boiler (20-60 bar) | 0.5 – 2 mg/l MEKO |
| High pressure boiler (> 60 bar) | 0.5 – 1 mg/l MEKO |
| Property | Value |
|---|---|
| Parameters | MEKO (methyl ethyl ketoxime, C₄H₉NO) |
| Item number | 31-073402 |
| Method | Photometric (ferrozine) |
| Measuring principle | Photometric measurement with WINLAB Data Line Photometer |
| Measuring range | 0.5 to 10 mg/l MEKO |
| Duration of analysis | 8 minutes |
| Number of provisions | 100 |
| Number of reagents | 2 |
| Packaging | Plastic bag |
| Scope of delivery |
|---|
| 2 reagent bottles (reagent A, reagent B) with detailed labeling |
| 1 test tube with scale |
| Detailed operating instructions (DE/EN) |
| Safety data sheets for all reagents |
| Resealable plastic bag |
| Reagent | Volume | Shelf life | Notes |
|---|---|---|---|
| Reagent A (ferrozine) | 30 ml | 24 months (24M) | Ferrozine reagent, shake before use |
| Reagent B (reducing agent) | 10 ml | 24 months (24M) | Shake before use |
Shelf life: The shelf life starts from the date of manufacture (printed on the bottle).
After opening, the reagents should be used within 12 months.
Store the test kit in a dry, cool place (10-25°C) and protected from direct sunlight.
| Packaging | Plastic bag, Refill pack |
|---|