Our telephone system is currently out of service due to line work. You can reach us by e-mail at info@rls-wacon.de or by calling +49 (0)151/1054 1979 --- Our telephone system is currently out of service due to line work. You can reach us by e-mail at info@rls-wacon.de or by calling +49 (0)151/1054 1979 --- Our telephone system is currently out of service due to line work. You can reach us by e-mail at info@rls-wacon.de or by calling +49 (0)151/1054 1979 ---

p-value P25 series

Reagent for SYCON P
Select the desired properties:
Quantity
Add to Quote
Request a quote

Private customers can also find our range in our partner store Ampha-Analyse.

Reagent for p-value P25 series:
See also:

Reagent p-value P25 series

What is the p-value measured for?

The p-value (also acid capacity up to pH 8.2 or m-value/alkalinity) describes the concentration of hydroxide and carbonate ions in the water. It is a decisive parameter in boiler water and cooling water chemistry:

  • Boiler water: The p-value is a key parameter for correct alkalization. Too low values lead to corrosion, too high values can cause foaming and overflow problems.
  • Steam and condensate systems: Monitoring the p-value ensures that the alkalization remains in the optimum range.
  • Cooling water systems: The p-value influences the corrosion and limescale separation behavior.
  • Industrial process water: Control of water chemistry in closed circuits.

How does the Reagent work?

The P25 Reagents are liquid color reagents for fully automated p-value determination with the SYCON P analyzer. The device automatically takes a water sample, precisely doses the Reagent and measures the resulting coloration photometrically.

Two measuring ranges are available: P25-5 for the low range (0.2-5.0 mmol/l) and P25-20 for higher concentrations (0.8-20.0 mmol/l).

Advantages of the P25 series

  • Two measuring ranges: P25-5 (0.2-5 mmol/l) and P25-20 (0.8-20 mmol/l)

    Precise measurement over a wide concentration range

  • Fully automatic measurement with the SYCON P

    Continuous 24/7 monitoring of boiler water chemistry

  • High-quality raw materials and our own recipe

    Manufactured by RLS Wacon – Made in Germany

  • Single batch calibration

    Consistently high precision with every delivery

  • Available as single bottle (500 ml) and value pack (4 × 500 ml)

    Economical container sizes for every need

  • 24 months shelf life

    Cost-efficient stockpiling

Areas of application

Boiler water
Steam and condensate systems
Cooling water
Industrial process water
Power plants

Changing the indicator on the device

Only use indicator bottles with a capacity of 500 ml. They can be changed directly on the SYCON P analyzer without tools.

Procedure

Wearing protective gloves is recommended.
  1. Deactivate automatic mode on the device.
  2. Loosen the screw cap on the bottle and insert a new indicator bottle – absorb any drips.
  3. Flush the measuring chamber (menu > Service > Manual flushing).
  4. Pump the Reagent into the measuring chamber (menu > Service > Pump Reagent) until the Reagent arrives free of bubbles. Confirm with [OK].
  5. Indicates whether a full bottle has been inserted (fill level indicator).
  6. Rinse the measuring chamber again and test the analysis procedure by starting an analysis.
  7. Activate automatic mode again.

Important notes

  • Check the expiration date on the bottle before use – only use Reagent that has not expired.
  • When switching between P25-5 and P25-20, the device must be reconfigured accordingly.
  • If you have any questions about the configuration, please contact our technical support.

Measuring range

Reagent Measuring range (mmol/l) Article no. (1x 500 ml) Item no. (4x 500 ml)
P25-5 0,2 – 5,0 32-086335 32-486335
P25-20 0,8 – 20,0 32-086345 32-486345
Note:
For most boiler water applications in the low-pressure range, the P25-5 Reagent is sufficient. For high pressure boilers or higher alkalized water we recommend the P25-20.

What to do if measured values are out of range?

Measured value > 5.0 mmol/l (when using P25-5)

Change to the P25-20 Reagent for the extended measuring range up to 20 mmol/l. The device must be reconfigured accordingly.

Measured value < 0.8 mmol/l (when using P25-20)

Change to the P25-5 Reagent for more precise measurements in the low range.

Specifications at a glance

Property Value
Parameter p-value (acid capacity up to pH 8.2)
Series P25
Method Colorimetric (photometric evaluation)
Measuring principle Fully automatic Reagent dosing and color measurement
Unit mmol/l
Measuring range P25-5 0.2 – 5.0 mmol/l
Measuring range P25-20 0.8 – 20.0 mmol/l
Container size 500 ml single bottle
Value pack 4 × 500 ml
Shelf life 24 months from date of manufacture
Manufacturer RLS Wacon analytics GmbH, Hildesheim

Compatible devices

Device Operating mode Status
SYCON P Measuring range Active

Storage conditions

Store in a cool, dry and dark place. Do not freeze. Protect from direct sunlight.
Shelf life: 24 months from date of manufacture (see label on the bottle). Use as soon as possible after opening.

Quality control

All Reagents are manufactured in-house at RLS Wacon according to strict quality standards. Each batch is individually calibrated and tested – Made in Germany.

Additional information

Limit value/measuring range

5, 20

Packaging

1x 500 ml, 4x 500 ml

Flyer
Operating instructions