Upgrade Kit from LIMESBASE to LIMESPLUS
Upgrade kit (re-pluggable circuit board) for the reversible extension of LIMESBASE to LIMESPLUS.

Private customers can also find our range in our partner store Ampha-Analyse.
Reagent for Upgrade Kit from LIMESBASE to LIMESPLUS:
See also:
Upgrade Kit from LIMESBASE to LIMESPLUS
What is it used for?
With the upgrade kit, you can upgrade an existing LIMESBASE device to the more powerful LIMESPLUS – without buying a new one. The kit contains a circuit board that is simply plugged in; no special technical knowledge is required, and the upgrade is reversible at any time.
What LIMESPLUS additionally offers
LIMESPLUS extends the capabilities of LIMESBASE in terms of analysis interval and system control:
- Selectable analysis interval (5 / 10 / 20 / 30 min instead of a fixed 10 min)
- Freely usable input contact (start/stop)
- Connection to an external control system (e.g. control room, reverse osmosis)
- Additional digital input
- Reversible: can be converted back to LIMESBASE by re-plugging the circuit board
Application
Disconnect the device from the power supply, re-plug the supplied circuit board according to the enclosed installation instructions and put the device back into operation – the LIMES then works as a LIMESPLUS. The upgrade can be reversed at any time.
💡 Note
Only carry out work on the electronics when the device is disconnected from the power supply. The exact procedure is described in the installation instructions enclosed with the kit.
Specifications at a glance
| Property | Value |
|---|---|
| Function | Upgrade LIMESBASE → LIMESPLUS |
| Principle | Re-pluggable circuit board, reversible |
| Installation | without special knowledge, with enclosed instructions |
| Scope of delivery | Upgrade circuit board, installation instructions |
| Suitable for | LIMESBASE devices |
| Article number | 30-035205 |
Additional information
| Product category | Accessories |
|---|---|
| Series | LIMES |
Flyer
Operating instructions
Similar articles:
Related products
-
LIMES maintenance setMaintenance kit for the LIMES – all important wearing parts in one set (peristaltic pump cassette, suction lance, injector, O-rings, stirrer blade, measuring chamber). -
Connection setComplete connection set for the water-side connection of SYCON analysers (¾”/½”) – stainless-steel fittings, socket ball valve and 5 m hose. -
WACON AcrylClean
WACON AcrylClean – the new measuring-chamber cleaner for the acrylic-glass measuring chambers of the SYCON and LIMES series. New formula, not a hazardous substance, 1000 ml.